Manifold directional control valves Parts

Showing 2,809–2,832 of 3,143 parts
Danfoss 02-351243 – DG4V 3 56BL M U D6 60, DG4V356BLMUD660
Danfoss
02-351243

DG4V 3 56BL M U D6 60, DG4V356BLMUD660

Danfoss 02-351086 – DG4V 3 6C H M U D6 60 EN38, DG4V36CHMUD660EN38
Danfoss
02-351086

DG4V 3 6C H M U D6 60 EN38, DG4V36CHMUD660EN38

Danfoss 02-351085 – DG4V 3 2AL H M U D6 60 EN38, DG4V32ALHMUD660EN38
Danfoss
02-351085

DG4V 3 2AL H M U D6 60 EN38, DG4V32ALHMUD660EN38

Danfoss 02-351000 – KDG4V 3 2C28S M U HA7 60, KDG4V32C28SMUHA760
Danfoss
02-351000

KDG4V 3 2C28S M U HA7 60, KDG4V32C28SMUHA760

Danfoss 02-350940 – KDG4V3 2C13N Z M U G7 60, KDG4V32C13NZMUG760
Danfoss
02-350940

KDG4V3 2C13N Z M U G7 60, KDG4V32C13NZMUG760

Danfoss 02-350939 – KDG4V3-33C20N-Z-M-U-G7-60, KDG4V333C20NZMUG760
Danfoss
02-350939

KDG4V3-33C20N-Z-M-U-G7-60, KDG4V333C20NZMUG760

Danfoss 02-350824 – DG4V 3 52C M U DN6 60, DG4V352CMUDN660
Danfoss
02-350824

DG4V 3 52C M U DN6 60, DG4V352CMUDN660

Danfoss 02-350795 – DG4V 3 32A M KUP1 G7 60, DG4V332AMKUP1G760
Danfoss
02-350795

DG4V 3 32A M KUP1 G7 60, DG4V332AMKUP1G760

Danfoss 02-350575 – KDG4V3-2C20N-M-U-GP7-60, KDG4V32C20NMUGP760
Danfoss
02-350575

KDG4V3-2C20N-M-U-GP7-60, KDG4V32C20NMUGP760

Danfoss 02-350453 – DG4V-3-2A-M-U-H7-60-P16, DG4V32AMUH760P16
Danfoss
02-350453

DG4V-3-2A-M-U-H7-60-P16, DG4V32AMUH760P16

Danfoss 02-350439 – DG4V-3-22BL-M-U-A6-60, DG4V322BLMUA660
Danfoss
02-350439

DG4V-3-22BL-M-U-A6-60, DG4V322BLMUA660

Danfoss 02-350420 – KDG4V 3 33C30X H M U H760 EN4 7, KDG4V333C30XHMUH760EN47
Danfoss
02-350420

KDG4V 3 33C30X H M U H760 EN4 7, KDG4V333C30XHMUH760EN47

Danfoss 02-350369 – DG4V-3-2A-M-U-H7-60-P10, DG4V32AMUH760P10
Danfoss
02-350369

DG4V-3-2A-M-U-H7-60-P10, DG4V32AMUH760P10

Danfoss 02-350350 – DG4V 3 0A H M U C6 60, DG4V30AHMUC660
Danfoss
02-350350

DG4V 3 0A H M U C6 60, DG4V30AHMUC660

Danfoss 02-350349 – DG4V 5 56C H M U C6 20, DG4V556CHMUC620
Danfoss
02-350349

DG4V 5 56C H M U C6 20, DG4V556CHMUC620

Danfoss 02-350314 – KDG5V 7 2C180N EX H VM UH1 10, KDG5V72C180NEXHVMUH110
Danfoss
02-350314

KDG5V 7 2C180N EX H VM UH1 10, KDG5V72C180NEXHVMUH110

Danfoss 02-350313 – KDG4V3 33C20N H VM U H760, KDG4V333C20NHVMUH760
Danfoss
02-350313

KDG4V3 33C20N H VM U H760, KDG4V333C20NHVMUH760

Danfoss 02-350312 – KDG4V3 33C20N10 H VM U H7 60, KDG4V333C20N10HVMUH760
Danfoss
02-350312

KDG4V3 33C20N10 H VM U H7 60, KDG4V333C20N10HVMUH760

Danfoss 02-350304 – DG4V-3-8B-H-VM-U-C6-61, DG4V38BHVMUC661
Danfoss
02-350304

DG4V-3-8B-H-VM-U-C6-61, DG4V38BHVMUC661

Danfoss 02-350289 – KDG4V3 2C20N M U HA7 60, KDG4V32C20NMUHA760
Danfoss
02-350289

KDG4V3 2C20N M U HA7 60, KDG4V32C20NMUHA760

Danfoss 02-350263 – DG4V-3-48N-VM-U-H7-60, DG4V348NVMUH760
Danfoss
02-350263

DG4V-3-48N-VM-U-H7-60, DG4V348NVMUH760

Danfoss 02-350252 – DG4V 5 34C VM U EK6 20, DG4V534CVMUEK620
Danfoss
02-350252

DG4V 5 34C VM U EK6 20, DG4V534CVMUEK620

Danfoss 02-350202 – DG4V 5 2B VM U A6 20, DG4V52BVMUA620
Danfoss
02-350202

DG4V 5 2B VM U A6 20, DG4V52BVMUA620

Danfoss 02-350149 – DG4V 3 0A M KUP3 H7 60 EN125, DG4V30AMKUP3H760EN125
Danfoss
02-350149

DG4V 3 0A M KUP3 H7 60 EN125, DG4V30AMKUP3H760EN125

Compare Manifold directional control valves

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNCoil RatingModel Code 1Power ConsumptionSpool TypeSpring Arrangement
02-351243220 VAC 50 Hz/240 VAC 60 HzDG4V356BLMUD66061VA 50HZ - 58VA 60HZSpool 56Spring offset end to centre LH
02-351086220 VAC 50 Hz/240 VAC 60 HzDG4V36CHMUD660EN3861VA 50HZ - 58VA 60HZSpool 6Spring centred
02-351085220 VAC 50 Hz/240 VAC 60 HzDG4V32ALHMUD660EN3861VA 50HZ - 58VA 60HZSpool 2Spring offset end to end LH
02-351000—KDG4V32C28SMUHA760—ISO4401-10/NFPA D10/CETOP 10/NG32—
02-350940—KDG4V32C13NZMUG760—ISO4401-10/NFPA D10/CETOP 10/NG32—
02-350939—KDG4V333C20NZMUG760—P blocked, A & B to tank—
02-350824220 VAC 60HzDG4V352CMUDN66058 VASpool 52Spring centred
02-35079512 VDCDG4V332AMKUP1G76030 wattSpool 32Spring offset end to end
02-350575—KDG4V32C20NMUGP760—ISO4401-10/NFPA D10/CETOP 10/NG32—
02-35045324 VDCDG4V32AMUH760P1630 wattSpool 2Spring offset end to end
02-350439110 VAC 50HzDG4V322BLMUA66054 VASpool 22Spring offset end to centre LH
02-350420—KDG4V333C30XHMUH760EN47—P blocked, bleed A & B to T—
02-35036924 VDCDG4V32AMUH760P1030 wattSpool 2Spring offset end to end
02-350350220 VAC 50HzDG4V30AHMUC66054 VASpool 0Spring offset end to end
02-350349220 VAC 50HzDG4V556CHMUC620105 VASpool 56Spring centred
02-350314—KDG5V72C180NEXHVMUH110—ISO4401-10/NFPA D10/CETOP 10/NG32—
02-350313—KDG4V333C20NHVMUH760—P blocked, A & B to tank—
02-350312—KDG4V333C20N10HVMUH760—P blocked, A & B to tank—
02-350304220 VAC 50HzDG4V38BHVMUC66154 VASpool 8Spring offset end to centre
02-350289—KDG4V32C20NMUHA760—ISO4401-10/NFPA D10/CETOP 10/NG32—
02-35026324 VDCDG4V348NVMUH76030 wattSpool 48No spring detented
02-350252115 VAC 60HzDG4V534CVMUEK620130 VASpool 34Spring centred
02-350202110 VAC 50HzDG4V52BVMUA620105 VASpool 2Spring offset end to centre
02-35014924 VDCDG4V30AMKUP3H760EN12530 wattSpool 0Spring offset end to end