SIRIUS 3RV2 motor starter protectors Parts
























Compare SIRIUS 3RV2 motor starter protectors
Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.
| MPN | continuous current rated value | Net Weight | adjustable current response value current of the current-dependent overload release | operational current rated value | response value current of instantaneous short-circuit trip unit |
|---|---|---|---|---|---|
| 3RV2111-1GA10 | 6.3 A | 390.58 g | 4.5 ... 6.3 A | 6.3 A | 82 A |
| 3RV2111-1FA10 | 5 A | 401.23 g | 3.5 ... 5 A | 5 A | 65 A |
| 3RV2111-1EA10 | 4 A | 383.58 g | 2.8 ... 4 A | 4 A | 52 A |
| 3RV2011-1EA10 | 4 A | 322.6 g | 2.8 ... 4 A | 4 A | 52 A |
| 3RV2011-1DA25-Z X95 | 3.2 A | 356.6 g | 2.2 ... 3.2 A | 3.2 A | 42 A |
| 3RV2011-1DA25-Z W97 | 3.2 A | 356.6 g | 2.2 ... 3.2 A | 3.2 A | 42 A |
| 3RV2011-1CA20-Z W96 | 2.5 A | 341.6 g | 1.8 ... 2.5 A | 2.5 A | 33 A |
| 3RV2011-1CA20 | 2.5 A | 341.6 g | 1.8 ... 2.5 A | 2.5 A | 33 A |
| 3RV2011-1CA15-0BA0 | 2.5 A | 0.335 kg | 1.8 ... 2.5 A | 2.5 A | 33 A |
| 3RV2011-1BA25-Z W96 | 2 A | 356.6 g | 1.4 ... 2 A | 2 A | 26 A |
| 3RV2011-1BA25 | 2 A | 356.6 g | 1.4 ... 2 A | 2 A | 26 A |
| 3RV2011-1BA20-Z X95 | 2 A | 343.6 g | 1.4 ... 2 A | 2 A | 26 A |
| 3RV2011-1BA20-Z W97 | 2 A | 343.6 g | 1.4 ... 2 A | 2 A | 26 A |
| 3RV2011-1BA20-Z W96 | 2 A | 343.6 g | 1.4 ... 2 A | 2 A | 26 A |
| 3RV2011-1BA20 | 2 A | 343.6 g | 1.4 ... 2 A | 2 A | 26 A |
| 3RV2021-0JA20 | 1 A | 372.6 g | 0.7 ... 1 A | 1 A | 13 A |
| 3RV2021-0JA15 | 1 A | 338.18 g | 0.7 ... 1 A | 1 A | 13 A |
| 3RV2021-0JA10-0DA0 | 1 A | 322.6 g | 0.7 ... 1 A | 1 A | 13 A |
| 3RV2021-0JA10-Z X95 | 1 A | 324.6 g | 0.7 ... 1 A | 1 A | 13 A |
| 3RV2021-0JA10-Z W97 | 1 A | 324.6 g | 0.7 ... 1 A | 1 A | 13 A |
| 3RV2021-0JA10-Z W96 | 1 A | 324.6 g | 0.7 ... 1 A | 1 A | 13 A |
| 3RV2021-0FA10 | 0.5 A | 0.262 kg | 0.35 ... 0.5 A | 0.5 A | 6.5 A |
| 3RV2021-0EA10-0DA0 | 0.4 A | 260.6 g | 0.28 ... 0.4 A | 0.4 A | 5.2 A |
| 3RV2021-0EA10 | 0.4 A | 0.261 kg | 0.28 ... 0.4 A | 0.4 A | 5.2 A |
Common to all listed parts
| Product equipment of circuit breaker for motor protection complete unit with protection device | Yes |
| size of contactor can be combined company-specific | S00, S0 |
| product function disconnector functionality | Yes |
| product extension auxiliary switch | Yes |
| type of calculation of power loss current-dependent | quadratic |
| insulation voltage with degree of pollution 3 at AC rated value | 690 V |
| surge voltage resistance rated value | 6 kV |
| reference code according to IEC 81346-2 | Q |