Relay module; Nominal input voltage: 220 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with manual operation; Red status indicator; Module width: 31 mm
Relay module; Nominal input voltage: 24 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with gold contacts; with manual operation; Railway; Red status indicator; Module width: 3
Relay module; Nominal input voltage: 24 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with gold contacts; with manual operation; Railway; Red status indicator; Module width: 31 mm 858-355
| Note | To prevent damaging the gold layer, 30 VDC switching voltages and 50 mA currents must not be exceeded. Higher switching power eventually evaporates the gold layer. The resulting deposits in the housing may reduce service life. |
| Nominal input voltage U<sub>N</sub> | 24 VDC |
| Input voltage range | -30 … +25 % |
| Nominal input current at U<sub>N</sub> | 42 mA |
| Number of changeover/switchover contacts | 4 |
| Contact material (relay) | AgCe + Au |
| Limiting continuous current | 5 A |
| Inrush current (resistive) max. | (AC) 15 A / 4 s |
| Switching Voltage, Max. | 250 VAC |
| Switching power (resistive) max. | AC 1000 VA; DC (see load limit curve) |
| Switching capacity | AC-15: 1 A / 240 VAC; DC-13: 2 A / 24 VDC |
| Recommended minimum load | 5 V / 1 mA / 50 mW |
| Pull-in time (typ.) | 25 ms |
| Drop-out time (typ.) | 25 ms |
| Bounce time (typ.) | 4 ms |
| Electrical life (NO; resistive load; 23 °C) | 100 x 10³ switching operations |
| Mechanical life | 20 x 10⁶ switching operations |
| Status indicator | Red LED, Mechanical |
| Rated voltage | 300 V |
| Rated impulse withstand voltage | 2.5 kV |
| Overvoltage category | II |
| Pollution degree | 2 |
| Dielectric strength (control/load circuit) (AC, 1 min) | 1.5 kVrms |
| Dielectric strength (open contact) (AC, 1 min) | 1 kVrms |
| Dielectric strength (load/load circuit) (AC, 1 min) | 1.5 kVrms |
| Insulation type (control/load circuit) | Basic insulation |
| Insulation type (open contact) | Functional insulation |
| Insulation type (load/load circuit) | Basic insulation |
| Insulation type (adjacent devices) | Reinforced insulation (safe isolation) |
| Protection type | IP20 |
| Connection technology | Push-in CAGE CLAMP® |
| Solid conductor | 0.34 … 1.5 mm² / 22 … 16 AWG |
| Fine-stranded conductor | 0.34 … 1.5 mm² / 22 … 16 AWG |
| Strip length | 9 … 10 mm / 0.35 … 0.39 inches |
| Note (conductor cross-section) | 2 x 0.34 … 2 x 1.5 mm² / 1 x 2.5 mm² / 2 x 22 … 2 x 16 AWG |
| Width | 31 mm / 1.22 inches |
| Height | 97 mm / 3.819 inches |
| Depth from upper-edge of DIN-rail | 73 mm / 2.874 inches |
| Mounting type | DIN-35 rail |
| Mounting position | horizontal (standing/lying); vertical |
| Note (material data) | Information on material specifications can be found here |
| Fire load | 1.254 MJ |
| Weight | 100.4 g |
| Ambient temperature (operation at U<sub>N</sub>) | -25 … +70 °C |
| Ambient temperature (storage) | -40 … +70 °C |
| Processing temperature | -25 … +50 °C |
| Temperature range of connection cable | ≥ (Tambient + 25 K) |
| Relative humidity | 5 … 85 % |
| Operating altitude (max.) | 2000 m |
| Standards/specifications | EN 61010-2-201, EN 61810-1, EN 61373, UL 508 |
| WAGO Basic Relay | 858-171 |
| Product Group | 6 (INTERFACE ELECTRONIC) |
| PU (SPU) | 5 pcs |
| Packaging type | box |
| Country of origin | CN |
| GTIN | 4055143567879 |
| Customs tariff number | 85364900990 |
| UNSPSC | 39122334 |
| eCl@ss 10.0 | 27-37-16-01 |
| eCl@ss 9.0 | 27-37-16-01 |
| ETIM 9.0 | EC001437 |
| ETIM 10.0 | EC001437 |
| ECCN | NO US CLASSIFICATION |
| RoHS Compliance Status | Compliant,No Exemption |
858-355 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Yes — mention it when you request a quote for 858-355 and we'll include express shipping options in our reply.
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 858-355, subject to availability and destination.

Relay module; Nominal input voltage: 220 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with manual operation; Red status indicator; Module width: 31 mm

Relay module; Nominal input voltage: 24 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with gold contacts; with manual operation; Red status indicator; Module width: 31 mm; 1,5

Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 12 A; with manual operation; Red status indicator; Module width: 31 mm; 1,50 mm²

Relay module; Nominal input voltage: 24 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with manual operation; Railway; Red status indicator; Module width: 31 mm

Relay module; Nominal input voltage: 24 VDC; 4 changeover contacts; Limiting continuous current: 6 A; with manual operation; Red status indicator; Module width: 31 mm; 1,50 mm²

Relay module; Nominal input voltage: 220 VDC; 4 changeover contacts; Limiting continuous current: 6 A; with manual operation; Red status indicator; Module width: 31 mm; 1,50 mm²; gray

Relay module; Nominal input voltage: 110 VDC; 4 changeover contacts; Limiting continuous current: 6 A; with manual operation; Red status indicator; Module width: 31 mm; 1,50 mm²