Basic relay; Nominal input voltage: 24 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with manual operation; Module width: 22 mm; Module height: 35mm
Basic relay; Nominal input voltage: 230 VAC; 2 changeover contacts; Limiting continuous current: 12 A; with manual operation; Module width: 22 mm; Module height: 35mm
Basic relay; Nominal input voltage: 230 VAC; 2 changeover contacts; Limiting continuous current: 12 A; with manual operation; Module width: 22 mm; Module height: 35mm 858-189
| Nominal input voltage U<sub>N</sub> | 230 VAC |
| Nominal input current at U<sub>N</sub> | 11 mA |
| Number of changeover/switchover contacts | 2 |
| Contact material (relay) | AgNi |
| Limiting continuous current | 12 A |
| Inrush current (resistive) max. | (AC) 24 A / 4 s |
| Switching Voltage, Max. | 250 VAC |
| Switching power (resistive) max. | AC 3000 VA; DC (see load limit curve) |
| Switching capacity | AC-15: 1.5 A / 240 VAC; DC-13: 0.1 A / 250 VDC |
| Recommended minimum load | 10 V / 5 mA / 300 mW |
| Pull-in time (typ.) | 10 ms |
| Drop-out time (typ.) | 8 ms |
| Electrical life (NO; resistive load; 23 °C) | 100 x 10³ switching operations |
| Mechanical life | 20 x 10⁶ switching operations |
| Switching frequency with/without load (max.) | 20 min-1 / 200 min-1 |
| Status indicator | Red LED, Mechanical |
| Dielectric strength (control/load circuit) (AC, 1 min) | 2.5 kVrms |
| Dielectric strength (open contact) (AC, 1 min) | 1.5 kVrms |
| Dielectric strength (load/load circuit) (AC, 1 min) | 2.5 kVrms |
| Protection type | IP20 |
| Width | 21.2 mm / 0.835 inches |
| Height from the surface | 35.6 mm / 1.402 inches |
| Depth | 27.5 mm / 1.083 inches |
| Mounting type | Pluggable module |
| Note (material data) | Information on material specifications can be found here |
| Weight | 31.5 g |
| Ambient temperature (operation at U<sub>N</sub>) | -40 … +55 °C |
| Ambient temperature (storage) | -40 … +85 °C |
| Standards/specifications | EN 61810-1 |
| PU (SPU) | 3 pcs |
| Packaging type | box |
| Country of origin | DE |
| GTIN | 4055143693264 |
| Customs tariff number | 85364900990 |
| UNSPSC | 39122334 |
| eCl@ss 10.0 | 27-37-16-01 |
| eCl@ss 9.0 | 27-37-16-01 |
| ETIM 9.0 | EC001437 |
| ETIM 10.0 | EC001437 |
| ECCN | NO US CLASSIFICATION |
| RoHS Compliance Status | Compliant,No Exemption |
858-189 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Yes — mention it when you request a quote for 858-189 and we'll include express shipping options in our reply.
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 858-189, subject to availability and destination.

Basic relay; Nominal input voltage: 24 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with manual operation; Module width: 22 mm; Module height: 35mm

Basic relay; Nominal input voltage: 24 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with gold contacts; with manual operation; Module width: 22 mm; Module height: 35mm

Basic relay; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 12 A; with manual operation; Module width: 22 mm; Module height: 35mm

Basic relay; Nominal input voltage: 220 VDC; 2 changeover contacts; Limiting continuous current: 12 A; with manual operation; Module width: 22 mm; Module height: 35mm

Relay module; Nominal input voltage: 12 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with manual operation; Red status indicator; Module width: 31 mm

Relay module; Nominal input voltage: 24 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with manual operation; Red status indicator; Module width: 31 mm; 1,50 mm²

Relay module; Nominal input voltage: 48 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with manual operation; Red status indicator; Module width: 31 mm; 1,50 mm²

Relay module; Nominal input voltage: 110 VDC; 4 changeover contacts; Limiting continuous current: 5 A; with manual operation; Red status indicator; Module width: 31 mm; 1,50 mm²