Wago 788-342

Relay module; Nominal input voltage: 48 VDC; 1 changeover contact; Limiting continuous current: 16 A; with manual operation; Red status indicator; Module width: 15 mm

MPN
788-342
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the Wago 788-342?

Relay module; Nominal input voltage: 48 VDC; 1 changeover contact; Limiting continuous current: 16 A; with manual operation; Red status indicator; Module width: 15 mm 788-342

Specifications

Notes

Safety InformationA separator plate (e.g., 209-191) must be used for voltages exceeding 250 V between adjacent relay modules and to comply with reinforced insulation requirements.
NoteReinforced insulation between coil and contacts, To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.

Technical data - Control circuit

Nominal input voltage U<sub>N</sub>48 VDC
Input voltage range±10 %
Nominal input current at U<sub>N</sub>9 mA

Technical data - Load circuit

Number of changeover/switchover contacts1
Contact material (relay)AgNi
Limiting continuous current16 A
Inrush current (resistive) max.(AC) 32 A / 0.02 s; (AC) 24 A / 4 s
Switching Voltage, Max.250 VAC
Switching power (resistive) max.AC 4000 VA; DC (see load limit curve)
Switching capacityAC-15: 3 A / 240 VAC; DC-13: 2 A / 24 VDC
Recommended minimum load12 V / 10 mA
Pull-in time (typ.)15 ms
Drop-out time (typ.)8 ms
Bounce time (typ.)6 ms
Electrical life (NO; resistive load; 23 °C)10 x 10³ switching operations
Mechanical life5 x 10⁶ switching operations
Switching frequency with/without load (max.)6 min-1 / 300 min-1

Technical data - Signaling

Status indicatorRed LED, Mechanical

Safety and protection

Rated voltage250 V
Rated impulse withstand voltage4 kV
Pollution degree3
Dielectric strength (control/load circuit) (AC, 1 min)5 kVrms
Dielectric strength (open contact) (AC, 1 min)1 kVrms
Safety InformationA separator plate (e.g., 209-191) must be used for voltages exceeding 250 V between adjacent relay modules and to comply with reinforced insulation requirements.
Protection typeIP20

Connection data

Connection technologyPush-in CAGE CLAMP®
Solid conductor0.34 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor0.34 … 2.5 mm² / 22 … 14 AWG
Strip length9 … 10 mm / 0.35 … 0.39 inches

Physical data

Width15 mm / 0.591 inches
Height86 mm / 3.386 inches
Depth from upper-edge of DIN-rail73 mm / 2.874 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Note (material data)Information on material specifications can be found here
Fire load0.689 MJ
Weight50 g

Environmental requirements

Ambient temperature (operation at U<sub>N</sub>)-40 … +70 °C
Ambient temperature UL (operation at U<sub>N</sub>)-40 … +50 °C
Ambient temperature (storage)-40 … +70 °C
Processing temperature-25 … +50 °C
Temperature range of connection cable≥ (Tambient + 20 K)

Standards and specifications

Standards/specificationsEN 61010-2-201, EN 61810-1, EN 61373, UL 508 (max. 10 A)

Commercial data

Product Group6 (INTERFACE ELECTRONIC)
PU (SPU)15 (1) pcs
Packaging typebox
Country of originDE
GTIN4050821226796
Customs tariff number85364900990

Product Classification

UNSPSC39122334
eCl@ss 10.027-37-16-01
eCl@ss 9.027-37-16-01
ETIM 9.0EC001437
ETIM 10.0EC001437
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption

788-342: frequently asked questions

When can 788-342 be shipped?

788-342 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 788-342 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 788-342 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 788-342, subject to availability and destination.

More Wago parts

Wago 788-313 – Relay module; Nominal input voltage: 48 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-313

Relay module; Nominal input voltage: 48 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-314 – Relay module; Nominal input voltage: 60 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-314

Relay module; Nominal input voltage: 60 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-315 – Relay module; Nominal input voltage: 110 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-315

Relay module; Nominal input voltage: 110 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-341 – Relay module; Nominal input voltage: 24 VDC; 1 changeover contact; Limiting continuous current: 16 A; with manual operation; Red status indicator; Module width: 15 mm
Wago
788-341

Relay module; Nominal input voltage: 24 VDC; 1 changeover contact; Limiting continuous current: 16 A; with manual operation; Red status indicator; Module width: 15 mm

Wago 788-344 – Relay module; Nominal input voltage: 110 VDC; 1 changeover contact; Limiting continuous current: 16 A; with manual operation; Red status indicator; Module width: 15 mm
Wago
788-344

Relay module; Nominal input voltage: 110 VDC; 1 changeover contact; Limiting continuous current: 16 A; with manual operation; Red status indicator; Module width: 15 mm

Wago 788-346 – Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 8 A; with manual operation; Red status indicator; Module width: 15 mm
Wago
788-346

Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 8 A; with manual operation; Red status indicator; Module width: 15 mm

Wago 788-347 – Relay module; Nominal input voltage: 48 VDC; 2 changeover contacts; Limiting continuous current: 8 A; with manual operation; Red status indicator; Module width: 15 mm
Wago
788-347

Relay module; Nominal input voltage: 48 VDC; 2 changeover contacts; Limiting continuous current: 8 A; with manual operation; Red status indicator; Module width: 15 mm

Wago 788-349 – Relay module; Nominal input voltage: 110 VDC; 2 changeover contacts; Limiting continuous current: 8 A; with manual operation; Red status indicator; Module width: 15 mm
Wago
788-349

Relay module; Nominal input voltage: 110 VDC; 2 changeover contacts; Limiting continuous current: 8 A; with manual operation; Red status indicator; Module width: 15 mm

Wago 788-342Price and lead time confirmed within 1 business day