Wago 788-311

Relay module; Nominal input voltage: 12 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

MPN
788-311
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Wago parts? We buy surplus →

What is the Wago 788-311?

Relay module; Nominal input voltage: 12 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray 788-311

Specifications

Notes

Safety InformationA separator plate (e.g., 209-191) must be used for voltages exceeding 250 V between adjacent relay modules and to comply with reinforced insulation requirements.
NoteReinforced insulation between coil and contacts, To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.

Technical data - Control circuit

Nominal input voltage U<sub>N</sub>12 VDC
Input voltage range±10 %
Nominal input current at U<sub>N</sub>36 mA

Technical data - Load circuit

Number of changeover/switchover contacts2
Contact material (relay)AgNi 90/10
Limiting continuous current8 A
Inrush current (resistive) max.(AC) 15 A / 4 s
Switching Voltage, Max.250 VAC
Switching power (resistive) max.AC 2000 VA; DC (see load limit curve)
Switching capacityAC-15: 3 A / 250 VAC; DC-13: 2 A / 24 VDC
Recommended minimum load12 V / 10 mA
Pull-in time (typ.)8 ms
Drop-out time (typ.)13 ms
Bounce time (typ.)10 ms
Electrical life (NO; resistive load; 23 °C)10 x 10³ switching operations
Mechanical life30 x 10⁶ switching operations
Switching frequency with/without load (max.)6 min-1 / 1200 min-1

Technical data - Signaling

Status indicatorRed LED

Safety and protection

Rated voltage250 V
Rated impulse withstand voltage4 kV
Pollution degree3
Dielectric strength (control/load circuit) (AC, 1 min)5 kVrms
Dielectric strength (open contact) (AC, 1 min)1 kVrms
Dielectric strength (load/load circuit) (AC, 1 min)2.5 kVrms
Safety InformationA separator plate (e.g., 209-191) must be used for voltages exceeding 250 V between adjacent relay modules and to comply with reinforced insulation requirements.
Protection typeIP20

Connection data

Connection technologyPush-in CAGE CLAMP®
Solid conductor0.34 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor0.34 … 2.5 mm² / 22 … 14 AWG
Strip length9 … 10 mm / 0.35 … 0.39 inches

Physical data

Width15 mm / 0.591 inches
Height86 mm / 3.386 inches
Depth from upper-edge of DIN-rail54 mm / 2.126 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Note (material data)Information on material specifications can be found here
Colorgray
Fire load0.67 MJ
Weight45.4 g

Environmental requirements

Ambient temperature (operation at U<sub>N</sub>)-40 … +70 °C
Ambient temperature UL (operation at U<sub>N</sub>)-40 … +50 °C
Ambient temperature (storage)-40 … +70 °C
Processing temperature-25 … +50 °C
Temperature range of connection cable≥ (Tambient + 20 K)

Standards and specifications

Standards/specificationsEN 61010-2-201, EN 61810-1, EN 61373, UL 508

Basic relay

WAGO Basic Relay788-152

Commercial data

Product Group6 (INTERFACE ELECTRONIC)
PU (SPU)20 (1) pcs
Packaging typebox
Country of originCN
GTIN4055143184120
Customs tariff number85364900990

Product Classification

UNSPSC39122334
eCl@ss 10.027-37-16-01
eCl@ss 9.027-37-16-01
ETIM 9.0EC001437
ETIM 10.0EC001437
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption
SCIP notification number (Austria)6cb17f3d-a438-4180-947f-430dbc9c5622
SCIP notification number (Belgium)f5ee941f-e9d8-4cfc-ab36-c2dbe3aa2603
SCIP notification number (Bulgaria)42048296-e89b-4a19-8cc8-c329f22cd90c
SCIP notification number (Czech Republic)12684f0d-ed36-4226-bcc3-6f9f1e3c12e8
SCIP notification number (Denmark)8d6dd953-b583-4558-95b2-154cd93ef817
SCIP notification number (Finland)411ef4a0-8b14-4733-bfee-0a07c8ab569d
SCIP notification number (France)576c1a8d-b2f1-45cc-bc30-a1ec7a13f9d3
SCIP notification number (Germany)3aed2e25-4110-44b8-b215-d3bfbc882a24
SCIP notification number (Hungary)35607a4c-44e5-44c9-ac03-b94610697251
SCIP notification number (Italy)ee02c7f0-8a4e-4812-a3ff-20672aa15ac9
SCIP notification number (Netherlands)0b7ded81-a4f9-4300-86c0-d4c7ceb401c2
SCIP notification number (Poland)ec289dc0-b26a-4fdd-bf55-f033332566cc
SCIP notification number (Romania)8c5dd94a-0b6d-4d59-8d75-24f638fe372f
SCIP notification number (Sweden)51d232f7-c7af-4143-872d-16428ba97485

788-311: frequently asked questions

When can 788-311 be shipped?

788-311 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 788-311 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 788-311 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 788-311, subject to availability and destination.

More Wago parts

Wago 788-304/003-000 – Relay module; Nominal input voltage: 24 VDC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-304/003-000

Relay module; Nominal input voltage: 24 VDC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-305 – Relay module; Nominal input voltage: 48 VDC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-305

Relay module; Nominal input voltage: 48 VDC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-306 – Relay module; Nominal input voltage: 60 VDC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-306

Relay module; Nominal input voltage: 60 VDC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-307 – Relay module; Nominal input voltage: 110 VDC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-307

Relay module; Nominal input voltage: 110 VDC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-312 – Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-312

Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-312/003-000 – Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm
Wago
788-312/003-000

Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm

Wago 788-313 – Relay module; Nominal input voltage: 48 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-313

Relay module; Nominal input voltage: 48 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-314 – Relay module; Nominal input voltage: 60 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-314

Relay module; Nominal input voltage: 60 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-311Price and lead time confirmed within 1 business day
Request a Quote