Electronic circuit breaker; 1-channel; 24 VDC input voltage; 1 A; NEC Class 2; Signal contact
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Protective Devices and Protective Electronics |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 787-3861/100-1000 be shipped?
787-3861/100-1000 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 787-3861/100-1000 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 787-3861/100-1000 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 787-3861/100-1000, subject to availability and destination.
Features:
Space-saving ECB with one channel
Reliably and safely trips in the event of an overload and short circuit on the secondary side
Switch-on capacity < 6,000 μF
Enables the use of an economical, standard power supply
Minimizes wiring via two voltage outputs and maximizes commoning options on both input and output sides (e.g., commoning of the output voltage on 857 and 2857 Series devices)
Status signal – adjustable as single or group message
Reset, switch on/off via remote input or local switch
Prevents power supply overload due to total inrush current thanks to time-delayed switching on during interconnected operation
Specifications
Notes
| Note | The device is designed for use in SELV circuits., Depending on the output current, please use the approved minimum conductor cross-sections., The device is designed for use in SELV circuits., Depending on the output current, please use the approved minimum conductor cross-sections: 26 AWG (0.5 A); 24 AWG (1 A) |
Technical data - Input
| Nominal input voltage U<sub>i nom</sub> | 24 VDC |
| Input voltage range | 18 … 30 VDC |
Technical data - Output
| Total number of channels (module) | 1 |
| Nominal output voltage U<sub>o nom</sub> | 1 x 24 VDC |
| Output voltage range | 18 … 30 VDC (Ue − voltage drop) |
| Voltage drop | ≤ 80 mV |
| Nominal output current I<sub>o nom</sub> | 1 x 1 A (fixed setting) |
| Default setting | switched off |
| Trip time | 4 ms … 100 s (load-dependent) |
| Switch-on behavior | Time-delayed channel switching (load-dependent, min. 0 ms / max. 500 ms) |
| Switch-on threshold | DC 20.3 V |
Technical data - Signaling and communication
| Signaling | 1 x Signal output (18 … 30 VDC, max. 0.015 A), default setting: tripped, 1 x Status LED (green/yellow/red), 1 x Signal output (18 … 30 VDC, max. 0.015 A), Default setting: triggered |
| Operation status indicator | Green LED (channel OK), Red LED (channel switched off) |
| Remote input | 1 x Control input (15 … 30 VDC (active high); 0 … 5 VDC (active low); max. 0.015 A) |
Technical data - Efficiency/power losses
| Power loss P<sub>l</sub> | ≤ 0.4 W (no load) |
| Efficiency (typ.) | 98 % |
Technical data - Circuit protection
| Internal fuse | T 4 A |
Safety and protection
| Isolation voltage (connectors – housing) | 1.5 kVDC |
| Protection class | III |
| Protection type | IP20; per EN 60529 |
| Reverse voltage protection | No |
| Transient suppression (primary) | Suppressor diode (33 V) |
| Parallel operation of single channels | Not permitted |
| Series operation | No |
| MTBF | 1,168,394 h |
Safety and protection - Insulation coordination (UL)
| Overvoltage category | II |
| Pollution degree | 2 |
Safety and protection - Insulation coordination
| Overvoltage category | II |
| Pollution degree | 2 |
Connection data
| Number of jumper slots | 8 |
Connection data - Connection 1
| Connection technology | Push-in CAGE CLAMP® |
| WAGO connector | WAGO 857 Series |
| Solid conductor | 0.08 … 2.5 mm² / 26 … 14 AWG |
| Fine-stranded conductor | 0.34 … 2.5 mm² / 22 … 14 AWG |
| Strip length | 9 … 10 mm / 0.35 … 0.39 inches |
| Note (conductor cross-section) | Depending on the output current, use the conductor cross-sections tested and approved by UL: 26 … 14 AWG (0.5 A);24 … 14 AWG (1 A) |
Physical data
| Width | 6 mm / 0.236 inches |
| Height | 94 mm / 3.701 inches |
| Depth from upper-edge of DIN-rail | 97.8 mm / 3.85 inches |
Mechanical data
| Mounting type | DIN-35 rail |
Material data
| Fire load | 0.631 MJ |
| Weight | 55.6 g |
Environmental requirements
| Ambient temperature (operation) | -25 … +70 °C |
| Ambient temperature (storage) | -40 … +85 °C |
| Relative humidity | 10 … 95 % (no condensation permissible) |
| Derating | No derating |
| Operating altitude | ≤ 2000 m (a.s.l.) |
Standards and specifications
| Conformity marking | CE; UKCA |
| Standards/specifications | EN 61000-6-2, EN 61000-6-3, UL 61010-2-201, DNV, UL 1310 (NEC Class 2), UL 2367 |
Commercial data
| PU (SPU) | 1 pcs |
| Packaging type | Bag |
| Country of origin | IN |
| Customs tariff number | 85362010900 |
Product Classification
| UNSPSC | 39121630 |
| ETIM 9.0 | EC001440 |
| ETIM 10.0 | EC001440 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| CAS-No. | 11120-22-2, 1303-86-2, 1317-36-8, 7439-92-1 |
| REACH Candidate List Substance | Diboron trioxide, Lead, Lead monoxide, Lead silicate |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Austria) | 75dcd74a-91d1-4057-b201-b7bbf10892b5 |
| SCIP notification number (Belgium) | 1b1f27cc-07f8-4ce7-a523-8d5f28bc04d4 |
| SCIP notification number (Bulgaria) | 27661f5a-9fe4-48c0-a768-5894a0fac69d |
| SCIP notification number (Czech Republic) | f6cc626e-0410-4f1c-8bef-d592570df280 |
| SCIP notification number (Denmark) | d2f0ceb3-219b-4cb9-84c2-cf20fddf9a7f |
| SCIP notification number (Finland) | 46940890-32f6-47ff-b2c3-c5319565618e |
| SCIP notification number (France) | 7f0370b6-61ab-4cf4-b850-79520ca088b5 |
| SCIP notification number (Germany) | 83497e1e-e446-403d-98cc-8676e9fa8977 |
| SCIP notification number (Hungary) | 12b11495-0199-4b22-92a8-24ac0c9b5a4d |
| SCIP notification number (Italy) | 14f282f8-8926-4b87-b5d9-6e95b8e791a1 |
| SCIP notification number (Netherlands) | d5b43b3a-9afb-44c8-a29b-a252cb4fead0 |
| SCIP notification number (Poland) | d40ed850-9c1e-48d1-8e8c-64a87bc72eae |
| SCIP notification number (Romania) | 7ef0433f-97c4-4f94-a73b-3f23a5f67287 |
| SCIP notification number (Sweden) | 42ca5865-1388-47a9-be81-80dcaa3ab5b6 |
More Wago parts
Available on requestElectronic circuit breaker; 1-channel; 24 VDC input voltage; adjustable 0.5 … 4 A; NEC Class 2; Signal contact
Available on requestElectronic circuit breaker; 1-channel; 24 VDC input voltage; 0.5 A; Signal contact
Available on requestElectronic circuit breaker; 1-channel; 24 VDC input voltage; 0.5 A; NEC Class 2; Signal contact
Available on requestElectronic circuit breaker; 1-channel; 24 VDC input voltage; 1 A; Signal contact
Available on requestElectronic circuit breaker; 1-channel; 24 VDC input voltage; adjustable 1 … 8 A; Signal contact
Available on requestElectronic circuit breaker; 1-channel; 24 VDC input voltage; 2 A; Signal contact
Available on requestElectronic circuit breaker; 1-channel; 24 VDC input voltage; 2 A; NEC Class 2; Signal contact
Available on requestElectronic circuit breaker; 1-channel; 24 VDC input voltage; 4 A; Signal contact