Field-wiring terminal block with linect<sup>®</sup>, 294 Series, Push-in CAGE CLAMP®
Field-wiring terminal block with linect<sup>®</sup> (item number 294-8215) is designed for fault-free electrical installations. Ensure that the strip lengths are between 8 and 9 mm when connecting conductors to field-wiring terminal block with linect<sup>®</sup>. Featuring four conductor terminals along with Push-in CAGE CLAMP® as well as PUSH WIRE®, this connector outperforms the competition. Push-in CAGE CLAMP® technology provides a universal connection solution for all conductor types. It allows both solid and fine-stranded conductors with ferrules to be inserted directly into the clamping point without the need for tools. Our PUSH WIRE® connection uses the stiffness of the conductor to overcome the clamping spring's contact force, allowing you to clamp the conductor in place more quickly and easily. The item's dimensions are (50 x 22.4 x 27.3) mm (width x height x depth). Depending on the conductor type, field-wiring terminal block with linect<sup>®</sup> is designed for conductor cross sections ranging from 0.5 mm² to 2.5 mm² on one side and for conductor cross sections from 0.5 mm² to 2.5 mm² on the other side as well as conductor cross sections from 0.5 mm² to 1.5 mm² and from 0.5 mm² to 0.75 mm².
Tin is used for coating the contact surfaces.
| Ratings | Connection points |
| Ratings per | IEC/EN 60998-1 |
| Nominal voltage (II/2) | 500 V |
| Rated impulse withstand voltage (II/2) | 4 kV |
| Rated current | 24 A |
| Legend (ratings) | (II / 2) ≙ Overvoltage category II / Pollution degree 2 |
| Ratings | Connection points / Connection points / Connection points |
| Ratings per | IEC/EN 60998-1 / IEC/EN 60998-1 / IEC/EN 60998-1 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 500 V |
| Rated impulse withstand voltage | 4 kV |
| Rated current | 24 A |
| Ratings | Connection points |
| Ratings per | IEC/EN 60998-2-2 |
| Rated voltage (II/2) | 500 V |
| Rated impulse withstand voltage (II/2) | 4 kV |
| Rated current | 24 A |
| Ratings | Connection points / Connection points / Connection points |
| Ratings per | IEC/EN 60998-2-2 / IEC/EN 60998-2-2 / IEC/EN 60998-2-2 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 500 V |
| Rated impulse withstand voltage | 4 kV |
| Rated current | 24 A |
| Ratings | Linect® plug-in connection |
| Ratings per | IEC/EN 61984 |
| Rated voltage (II/2) | 500 V |
| Rated impulse withstand voltage (II/2) | 4 kV |
| Rated current | 16 A |
| Ratings | Linect® plug-in connection / Linect® plug-in connection / Linect® plug-in connection |
| Ratings per | IEC/EN 61984 / IEC/EN 61984 / IEC/EN 61984 |
| Overvoltage category | III / III / II |
| Pollution degree | 3 / 2 / 2 |
| Nominal voltage | 500 V |
| Rated impulse withstand voltage | 4 kV |
| Rated current | 16 A |
| Total number of potentials | 5 |
| Number of connection types | 4 |
| PE function | Snap-in PE contact |
| Connection type | External 1 |
| Connection technology | Push-in CAGE CLAMP® |
| Number of connection points | 2 |
| Actuation type | Push-button |
| Solid conductor | 0.5 … 2.5 mm² / 18 … 12 AWG |
| Solid conductor; push-in termination | 0.5 … 2.5 mm² / 18 … 12 AWG |
| Stranded conductor | 0.5 … 2.5 mm² / 18 … 14 AWG |
| Fine-stranded conductor | 0.5 … 2.5 mm² / 18 … 14 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.5 … 1.5 mm² / 18 … 16 AWG |
| Fine-stranded conductor; with uninsulated ferrule | 0.5 … 1.5 mm² / 18 … 16 AWG |
| Fine-stranded conductor; with ferrule; push-in termination | 0.5 mm² / 18 AWG |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
| Pole number | 5 |
| Connection type | Internal 2 |
| Connection technology | PUSH WIRE® |
| Number of connection points | 1 |
| Actuation type | Push-in |
| Solid conductor | 0.5 … 2.5 mm² / 18 … 14 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.5 … 1 mm² / 18 … 14 AWG |
| Fine-stranded conductor; with uninsulated ferrule | 0.5 … 1.5 mm² / 18 … 16 AWG |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
| Connection type | Internal 3 |
| Connection technology | PUSH WIRE® |
| Number of connection points | 1 |
| Actuation type | Push-in |
| Solid conductor | 0.5 … 1.5 mm² / 18 … 16 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.5 … 0.75 mm² / 18 AWG |
| Fine-stranded conductor; with uninsulated ferrule | 0.5 … 1 mm² / 18 … 14 AWG |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
| Connection type | Internal 4 |
| Connection technology | PUSH WIRE® |
| Number of connection points | 1 |
| Actuation type | Push-in |
| Solid conductor | 0.5 … 0.75 mm² / 18 AWG |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
| Pin spacing | 10 mm / 0.394 inches |
| Width | 50 mm / 1.969 inches |
| Height | 22.4 mm / 0.882 inches |
| Height from the surface | 17 mm / 0.669 inches |
| Depth | 27.3 mm / 1.075 inches |
| Technology | Linect |
| Marking | L3 L2 L1 ⏚ N |
| Note (material data) | Information on material specifications can be found here |
| Color | white |
| Material group | IIIa |
| Insulation material (main housing) | Polycarbonate (PC) |
| Flammability class per UL94 | V0 |
| Clamping spring material | Chrome-nickel spring steel (CrNi) |
| Contact material | Electrolytic copper (ECu) |
| Contact plating | Tin |
| Fire load | 0.33 MJ |
| Weight | 17.1 g |
| Temperature stability | 120 °C |
| T marking | T85 |
| Product Group | 8 (Misc. Chassis Mount Blocks) |
| PU (SPU) | 250 pcs |
| Packaging type | bag |
| Country of origin | PL |
| GTIN | 4050821487067 |
| Customs tariff number | 85369010000 |
| UNSPSC | 39121409 |
| eCl@ss 10.0 | 27-14-11-06 |
| eCl@ss 9.0 | 27-14-11-06 |
| ETIM 9.0 | EC001284 |
| ETIM 10.0 | EC001284 |
| ECCN | NO US CLASSIFICATION |
| RoHS Compliance Status | Compliant,No Exemption |
| Technology | Linect |
No matching specifications
294-8215 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Yes — mention it when you request a quote for 294-8215 and we'll include express shipping options in our reply.
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 294-8215, subject to availability and destination.

Lighting connector; push-button, external; for Linect®; with direct ground contact; 1/L´-2/L-PE-N; 4-pole; Cod. A; Lighting side: for solid conductors; Inst. side: for all conductor types; ma

Lighting connector; push-button, external; for Linect®; with direct ground contact; L´-N´-L-PE-N; 5-pole; Cod. L; Lighting side: for solid conductors; Inst. side: for all conductor types; max

Lighting connector; push-button, external; for Linect®; with direct ground contact; DA+ DA- L PE N; 5-pole; Cod. I; Lighting side: for solid conductors; Inst. side: for all conductor types; m

Lighting connector; push-button, external; for Linect®; with snap-in ground contact; 3-pole; Cod. A; Lighting side: for solid conductors; Inst. side: for all conductor types; max. 2.5 mm²; Su

Lighting connector; push-button, external; for Linect®; with snap-in ground contact; 1/L´-2/L-PE-N; 4-pole; Cod. A; Lighting side: for solid conductors; Inst. side: for all conductor types; m

Lighting connector; push-button, external; for Linect®; with snap-in ground contact; L´-N´-L-PE-N; 5-pole; Cod. L; Lighting side: for solid conductors; Inst. side: for all conductor types; ma

Lighting connector; push-button, external; for Linect®; with angled snap-in ground contact; L3-L2-L1-PE-N; 5-pole; Cod. A; Lighting side: for solid conductors; Inst. side: for all conductor t

Lighting connector; push-button, external; for Linect®; with angled snap-in ground contact; 1/L´-2/L-PE-N; 4-pole; Cod. A; Lighting side: for solid conductors; Inst. side: for all conductor t