CODESYS License; Control Standard; L; Single License; Online activation
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Software |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 2762-2008/211-1000 be shipped?
2762-2008/211-1000 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 2762-2008/211-1000 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 2762-2008/211-1000 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 2762-2008/211-1000, subject to availability and destination.
This application-based license is specifically designed for use with CODESYS Virtual Control for Linux SL. It includes 2048 I/O channels and supports an application size of up to 6 MB. Suitable hardware platforms include WAGO Edge Computers (Order No.: 752-9400; 752-9401; 752-9800; 752-9412; 752-9813).
These licenses are hardware-independent and can be used across multiple products, offering maximum flexibility when selecting devices. Another advantage is the scaling of licenses based on application metrics, meaning you only pay for the CODESYS features you actually use.
Overview of application metrics for determining the appropriate license:
Standard S
EtherCAT/Profinet/EthernetIP: 1 instance
CANopen/Profibus/Modbus/J1939: 4 instances
Number of input/output channels: 512
Code size: 3 MB
incl. visualization S
incl. Management Communication S (e.g., OPC UA)
Reloadable C code
Standard M
EtherCAT/Profinet/EthernetIP: 1 instance
CANopen/Profibus/Modbus/J1939: 8 instances
Number of input/output channels: 1024
Code size: 5 MB
incl. visualization S
incl. Management Communication S (e.g., OPC UA)
Reloadable C code
Standard L
EtherCAT/Profinet/EthernetIP: 2 instances
CANopen/Profibus/Modbus/J1939: 10 instances
Number of input/output channels: 4096
Code size: 6 MB
incl. visualization S
incl. Management Communication S (e.g., OPC UA)
Reloadable C code
Core assignment of IEC task groups
Visualization S: License for target and web visualization with up to 128 tags
Management Communication S: OPC UA license for client and server with up to 512 tags
Licensing
Single Device License: The license can be used on the controller where the CODESYS runtime system is installed.
The license is activated in a software-based container (soft container) that is permanently bound to the controller.
Note: Without a license, the software will run in demo mode for two hours. After that, a manual restart is required.
Please note that the use of these application-based licenses requires CODESYS Development System V3.5.19.7 or higher and CODESYS Virtual Control SL Runtime Software Version 4.12.0.0 or higher.
Source: The required software can be obtained from the WAGO Download Center:
CODESYS: https://downloadcenter.wago.com/latest-of-productgroup/codesys
Runtime: https://downloadcenter.wago.com/software/latest/runtime-codesys-virtual-control-linux
Demo Mode
A controller without a license runs in demo mode for two hours. After this period, the runtime system will shut down and must be restarted manually. The functionality of demo mode is not restricted, but unlicensed functions have a shorter demo runtime (e.g., fieldbuses operate for 30 minutes).
License Check
When an application-based license is available on the controller, all criteria are checked against the limit stored in the license. If any criteria exceed the defined limit, the application download or boot application loading will be blocked. No transition to demo mode occurs.
This prevents the system from reverting to a time-limited demo mode during production.
Specifications
Software data
| Supported devices | WAGO Edge Computer 752-9400, 752-9401, 752-9800, 752-9412, 752-9813 |
| Supported fieldbuses | EtherCAT, PROFINET, EtherNet/IP, CANopen, PROFIBUS, Modbus, SAE J1939 |
Delivery
| License type | License including Local I/O, Visualization S / Communication S, DataSource Manager |
| Delivery type | License certificate by email (software available for download) |
| License type (note) | Single license allows installation on one device. One license per device is required. |
| License type (note) (2) | Internet connection may be required for license activation. |
| License generation | CODESYS |
Commercial data
| PU (SPU) | 1 pcs |
| Packaging type | not specified |
| Country of origin | QU |
| GTIN | 4066966504934 |
| Customs tariff number | 88888888888 |
Product Classification
| ETIM 10.0 | EC001435 |
| UNSPSC | 43,233,603 |
| ETIM 9.0 | EC001435 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| RoHS Compliance Status | Compliant,No Exemption |
More Wago parts
Available on requestRuntime; IEC60870 Master; L; Single License; Online activation
Available on requestMonitoring Solution; Cloud License S
Available on requestCODESYS License; Control Standard; S; Single License; Online activation
Available on requestCODESYS License; Control Standard; M; Single License; Online activation
Available on requestCODESYS License; Communication (OPC UA, Symbol Set); M; Single License; Online activation
Available on requestCODESYS License; Visualization; M; Single License; Online activation
Available on requestCODESYS License; Visualization; L; Single License; Online activation
Available on requestCODESYS License; Visualization; XL; Single License; Online activation