Wago 2759-2241/211-1000

Runtime; IEC61850 Server; L; Single License; Online activation

MPN
2759-2241/211-1000
Category
Software
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Wago parts? We buy surplus →

What is the Wago 2759-2241/211-1000?

Function:

Communication according to the IEC 61850 protocol can be conveniently parameterized with the configurator. To enable this, the CODESYS V3 development environment must be extended once with the WAGO Telecontrol Package.

Users can create the IEC 61850 object structure directly in the configurator or import it from an IEC 61850 SCL file. The resulting configuration can be re-exported in SCL format for integration into an IEC 61850 client system. This saves time during engineering and helps avoid configuration errors. For online communication, the IEC 61850 server supports (un)buffered reporting in MMS* format and GOOSE* publishing.

This license activates the IEC 61850 protocol on the server side. It enables the creation of gateways for protocol conversion, e.g., reading data from protection devices via IEC 60870-103 and forwarding it to supervisory control systems using IEC 61850.

Key Benefits:

Create gateway applications to transmit data from local I/Os or from other protocols to a higher-level IEC 61850 control system

Forward control commands from a supervisory IEC 61850 control system to protection devices via GOOSE publishing, IEC 60870-5-103, or DNP3

Note: Additional software licenses may be required, such as the WAGO IEC 60870 Master or DNP3 Master.

Usage:

The license is registered via WAGO Upload and loaded onto a device. No further installation steps are required.

Technical Data:

See the product manual “Configuring the IEC-61850 Protocol.”

*MMS = Manufacturing Messaging Specification

*GOOSE = Generic Object Oriented Substation Event

Specifications

System requirements

Other required softwareCODESYS V3.5 SP16 and higher

Software data

Supported devicesTouch Panel 600; Control and Visu Panel, 750-8302: PFC300 Controller, 752-8303/8000-0002: Edge Controller

Delivery

Delivery typeLicense certificate per email
License type (note)Single license allows installation on one device. One license per device is required.
License type (note) (2)An Internet connection to the PC that's equipped with CODESYS or the WAGOupload tool may be required for license activation.
License generationDRM

Commercial data

PU (SPU)1 pcs
Packaging typenot specified
GTIN4066966666717
Customs tariff number88888888888

Product Classification

ETIM 10.0EC001435
UNSPSC43,232,408
ETIM 9.0EC001435
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption

2759-2241/211-1000: frequently asked questions

When can 2759-2241/211-1000 be shipped?

2759-2241/211-1000 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 2759-2241/211-1000 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 2759-2241/211-1000 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 2759-2241/211-1000, subject to availability and destination.

More Wago parts

Wago 2759-2120/261-1000 – Application Building Control; Single License; Online activation
Wago
2759-2120/261-1000

Application Building Control; Single License; Online activation

Wago 2759-2121/261-1000 – Application Building Control; S; Single License; Online activation
Wago
2759-2121/261-1000

Application Building Control; S; Single License; Online activation

Wago 2759-2226/211-1000 – Runtime; BACnet; 600 Plus; Single License; Online activation
Wago
2759-2226/211-1000

Runtime; BACnet; 600 Plus; Single License; Online activation

Wago 2759-2240/211-1000 – Runtime; IEC61850 Server; Single License; Online activation
Wago
2759-2240/211-1000

Runtime; IEC61850 Server; Single License; Online activation

Wago 2759-2243/211-1000 – Runtime; IEC61850 Client; M; Single License; Online activation
Wago
2759-2243/211-1000

Runtime; IEC61850 Client; M; Single License; Online activation

Wago 2759-2246/211-1000 – Runtime; IEC61850 Client; L; Single License; Online activation
Wago
2759-2246/211-1000

Runtime; IEC61850 Client; L; Single License; Online activation

Wago 2759-2273/211-1000 – Runtime; BACnet; 300; S; Single License; Online activation
Wago
2759-2273/211-1000

Runtime; BACnet; 300; S; Single License; Online activation

Wago 2759-2276/211-1000 – Runtime; BACnet; 600; S; Single License; Online activation
Wago
2759-2276/211-1000

Runtime; BACnet; 600; S; Single License; Online activation

Wago 2759-2241/211-1000Price and lead time confirmed within 1 business day
Request a Quote