Siemens 6AG1518-4JP00-4AB0

SIPLUS S7-1500 CPU 1518HF-4 PN based on 6ES7518-4JP00-0AB0 with conformal coating

MPN
6AG1518-4JP00-4AB0
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Siemens parts? We buy surplus →

What is the Siemens 6AG1518-4JP00-4AB0?

SIPLUS S7-1500 CPU 1518HF-4 PN based on 6ES7518-4JP00-0AB0 with conformal coating, central processing unit with 9 MB work memory for program and 60 MB for data, 1st interface: PROFINET RT with 2-port switch, 2nd interface: PROFINET, 3rd interface: PROFINET, 4th/5th interface: H-SYNC, SIMATIC Memory Card required

Specifications

General information

Product type designationCPU 1518HF-4PN
Firmware version — FW update possibleYes
based on6ES7518-4JP00-0AB0
Product function — I&M dataYes; I&M0 to I&M3
Product function — Isochronous modeNo
Product function — SysLogYes

Display

Screen diagonal [cm]6.1 cm

Control elements

Number of keys6
Mode selector switch1

Supply voltage

Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains buffering — Mains/voltage failure stored energy time5 ms

Input current

Current consumption (rated value)1.55 A
Current consumption, max.1.95 A
Inrush current, max.1.95 A; Rated value
I²t0.4 A²·s

Power

Infeed power to the backplane bus12 W
Power consumption from the backplane bus (balanced)30 W

Power loss

Power loss, typ.24 W

Storage

Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
Work memory — integrated (for program)9 Mbyte
Work memory — integrated (for data)60 Mbyte
Load memory — Plug-in (SIMATIC Memory Card), max.32 Gbyte
Backup — maintenance-freeYes

CPU processing times

for bit operations, typ.4 ns
for word operations, typ.6 ns
for fixed point arithmetic, typ.6 ns
for floating point arithmetic, typ.24 ns

CPU-blocks

Number of elements (total)20 000; Blocks (OB, FB, FC, DB) and UDTs
DB — Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
DB — Size, max.16 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB — Number range0 ... 65 535
FB — Size, max.1 Mbyte
FC — Number range0 ... 65 535
FC — Size, max.1 Mbyte
OB — Size, max.1 Mbyte
OB — Number of free cycle OBs100
OB — Number of time alarm OBs20
OB — Number of delay alarm OBs20
OB — Number of cyclic interrupt OBs20; with minimum OB 3x cycle of 1 ms
OB — Number of process alarm OBs50
OB — Number of DPV1 alarm OBs3
OB — Number of startup OBs100
OB — Number of asynchronous error OBs4
OB — Number of synchronous error OBs2
OB — Number of diagnostic alarm OBs1
Nesting depth — per priority class24; Up to 8 possible for F-blocks

Counters, timers and their retentivity

S7 counter — Number2 048
S7 counter — Retentivity — can be setYes
IEC counter — NumberAny (only limited by the main memory)
IEC counter — Retentivity — can be setYes
S7 timer — Number2 048
S7 timer — Retentivity — adjustableYes
IEC timer — NumberAny (only limited by the main memory)
IEC timer — Retentivity — can be setYes

Data areas and their retentivity

Retentive data area (incl. timers, counters, flags), max.768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB
Flag — Size, max.16 kbyte
Flag — Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data blocks — Retentivity adjustableYes
Data blocks — Retentivity presetNo
Local data — per priority class, max.64 kbyte; max. 16 KB per block

Address area

Number of IO modules8 192; max. number of modules / submodules
I/O address area — Inputs32 kbyte; All inputs are in the process image
I/O address area — Outputs32 kbyte; All outputs are in the process image
I/O address area — per integrated IO subsystem — Inputs (volume)16 kbyte
I/O address area — per integrated IO subsystem — Outputs (volume)16 kbyte
Subprocess images — Number of subprocess images, max.31

Hardware configuration

Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET, but also by the connection of I/O via IE/PB-Links.
Number of IO Controllers — Integrated1
Rack — Modules per rack, max.9; CPU + 2 PS + 6 CP

Time of day

Clock — TypeHardware clock
Clock — Backup time6 wk; At 40 °C ambient temperature, typically
Clock — Deviation per day, max.10 s; Typ.: 2 s
Operating hours counter — Number16
Clock synchronization — supportedYes
Clock synchronization — on Ethernet via NTPYes

Interfaces

Number of PROFINET interfaces3

1. Interface

Interface types — RJ 45 (Ethernet)Yes; X1
Interface types — Number of ports2
Interface types — integrated switchYes
Protocols — IP protocolYes; IPv4
Protocols — PROFINET IO ControllerYes
Protocols — PROFINET IO deviceNo
Protocols — SIMATIC communicationYes; Only Server
Protocols — Open IE communicationYes; Optionally also encrypted
Protocols — Web serverNo
Protocols — Media redundancyYes
PROFINET IO Controller — Services — Isochronous modeNo
PROFINET IO Controller — Services — IRTNo
PROFINET IO Controller — Services — Dynamic Frame Packing (DFP)Yes
PROFINET IO Controller — Services — PROFIenergyYes; per user program
PROFINET IO Controller — Services — Prioritized startupNo
PROFINET IO Controller — Services — Number of connectable IO Devices, max.256
PROFINET IO Controller — Services — Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
PROFINET IO Controller — Services — PROFINET Security Class1
PROFINET IO Controller — Update time for RT — for send cycle of 1 ms1 ms to 512 ms

2. Interface

Interface types — RJ 45 (Ethernet)Yes; X2
Interface types — Number of ports1
Interface types — integrated switchNo
Protocols — IP protocolYes; IPv4
Protocols — PROFINET IO ControllerNo
Protocols — PROFINET IO deviceNo
Protocols — SIMATIC communicationYes; Only Server
Protocols — Open IE communicationYes; Optionally also encrypted
Protocols — Web serverYes
Protocols — Media redundancyNo

3. Interface

Interface types — RJ 45 (Ethernet)Yes; X3
Interface types — Number of ports1
Interface types — integrated switchNo
Protocols — IP protocolYes; IPv4
Protocols — PROFINET IO ControllerNo
Protocols — PROFINET IO deviceNo
Protocols — SIMATIC communicationYes; Only Server
Protocols — Open IE communicationYes; Optionally also encrypted
Protocols — Web serverYes

4. Interface

Interface typePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization module 6ES7960-1CB00-0AA5 or 6ES7960-1FB00-0AA5

5. Interface

Interface typePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization module 6AG1960-1CB00-4AA5 or 6AG1960-1FB00-4AA5

Interface types

RJ 45 (Ethernet) — 100 MbpsYes
RJ 45 (Ethernet) — 1000 MbpsYes; Only possible at the X3 interface of the CPU 1518
RJ 45 (Ethernet) — AutonegotiationYes
RJ 45 (Ethernet) — AutocrossingYes
RJ 45 (Ethernet) — Industrial Ethernet status LEDYes

Protocols

PROFIsafeYes; V2.4 / V2.6
Number of connections — Number of connections, max.384; via integrated interfaces of the CPU and connected CPs
Number of connections — Number of connections reserved for ES/HMI/web10
Number of connections — Number of connections via integrated interfaces320
Number of connections — Number of S7 routing paths64
Redundancy mode — PROFINET system redundancy (S2)Yes
Redundancy mode — PROFINET system redundancy (R1)Yes
Redundancy mode — Media redundancy — Media redundancyonly via 1st interface (X1)
Redundancy mode — Media redundancy — MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0
Redundancy mode — Media redundancy — MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
Redundancy mode — Media redundancy — MRPDNo
Redundancy mode — Media redundancy — Switchover time on line break, typ.200 ms; PROFINET MRP
Redundancy mode — Media redundancy — Number of stations in the ring, max.50
SIMATIC communication — PG/OP communicationYes; encryption with TLS V1.3 pre-selected
SIMATIC communication — S7 routingYes
SIMATIC communication — S7 communication, as serverYes
SIMATIC communication — S7 communication, as clientNo
Open IE communication — TCP/IPYes
Open IE communication — TCP/IP — Data length, max.64 kbyte
Open IE communication — TCP/IP — several passive connections per port, supportedYes
Open IE communication — ISO-on-TCP (RFC1006)Yes
Open IE communication — ISO-on-TCP (RFC1006) — Data length, max.64 kbyte
Open IE communication — UDPYes
Open IE communication — UDP — Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
Open IE communication — UDP — UDP multicastYes; 128 multicast circuits (of which max. 5 via X1)
Open IE communication — DHCPNo
Open IE communication — DNSYes
Open IE communication — SNMPYes
Open IE communication — DCPYes
Open IE communication — LLDPYes
Open IE communication — encryptionYes; Optional
Web server — HTTPNo
Web server — HTTPSYes; only via Web API
Web server — web APIYes
Web server — web API — Number of sessions, max.200
Web server — web API — number of simultaneous HTTP calls, max.4
Web server — web API — HTTP request body, max.131 072 byte
OPC UA — Runtime license requiredYes; "Large" license required per CPU
OPC UA — OPC UA ClientNo
OPC UA — OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
OPC UA — OPC UA Server — Application authenticationYes
OPC UA — OPC UA Server — Security policiesavailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss
OPC UA — OPC UA Server — User authentication"anonymous" or by user name & password
OPC UA — OPC UA Server — GDS support (certificate management)No
OPC UA — OPC UA Server — Number of sessions, max.32
OPC UA — OPC UA Server — Number of subscriptions per session, max.25
OPC UA — OPC UA Server — Sampling interval, min.25 ms
OPC UA — OPC UA Server — Publishing interval, min.25 ms
OPC UA — OPC UA Server — Number of server methods, max.100
OPC UA — OPC UA Server — Number of inputs/outputs per server method, max.20
OPC UA — OPC UA Server — Number of monitored items, recommended max.12 000; for 1 s sampling interval and 1 s send interval
OPC UA — OPC UA Server — Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
OPC UA — OPC UA Server — Number of nodes for user-defined server interfaces, max.50 000
OPC UA — Alarms and ConditionsNo
Further protocols — MODBUSYes; MODBUS TCP

Isochronous mode

EquidistanceNo

S7 message functions

Number of login stations for message functions, max.64
number of subscriptions, max.750
number of tags/attributes for subscriptions, max.50 000
Program alarmsYes
Number of configurable program messages, max.10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.10 000
Number of simultaneously active program alarms — Number of program alarms4 000
Number of simultaneously active program alarms — Number of alarms for system diagnostics1 000

Test commissioning functions

Joint commission (Team Engineering)No
Status blockYes; Up to 16 simultaneously
Single stepNo
Number of breakpoints20; Breakpoints are only supported in RUN-Solo status
Status/control — Status/control variableYes
Status/control — Variablesinputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters
Status/control — Number of variables, max. — of which status variables, max.200; per job
Status/control — Number of variables, max. — of which control variables, max.200; per job
Forcing — ForcingYes; without fail-safe
Forcing — Forcing, variablesperipheral inputs/outputs (without fail-safe)
Forcing — Number of variables, max.200
Diagnostic buffer — presentYes
Diagnostic buffer — Number of entries, max.3 200
Diagnostic buffer — Number of entries, max. — of which powerfail-proof1 000
Traces — Number of configurable Traces8
Traces — Memory size per trace, max.512 kbyte

Interrupts/diagnostics/status information

Diagnostics indication LED — RUN/STOP LEDYes
Diagnostics indication LED — ERROR LEDYes
Diagnostics indication LED — MAINT LEDYes
Diagnostics indication LED — Connection display LINK TX/RXYes

Supported technology objects

Motion ControlNo
Controller — PID_CompactYes; Universal PID controller with integrated optimization
Controller — PID_3StepYes; PID controller with integrated optimization for valves
Controller — PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuringYes

Standards, approvals, certificates

Highest safety class achievable in safety mode — Performance level according to ISO 13849-1PLe
Highest safety class achievable in safety mode — SIL acc. to IEC 61508SIL 3
Highest safety class achievable in safety mode — Probability of failure (for service life of 20 years and repair time of 100 hours) — Low demand mode: PFDavg in accordance with SIL3< 2.00E-05
Highest safety class achievable in safety mode — Probability of failure (for service life of 20 years and repair time of 100 hours) — High demand/continuous mode: PFH in accordance with SIL3< 1.00E-09

Security

PROFINET Security Class1

Ambient conditions

Ambient temperature during operation — horizontal installation, min.0 °C
Ambient temperature during operation — horizontal installation, max.60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
Ambient temperature during operation — vertical installation, min.0 °C
Ambient temperature during operation — vertical installation, max.40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
Ambient temperature during storage/transportation — min.-40 °C
Ambient temperature during storage/transportation — max.70 °C
Altitude during operation relating to sea level — Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Relative humidity — With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Resistance — Coolants and lubricants — Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Resistance — Use in stationary industrial systems — to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
Resistance — Use in stationary industrial systems — to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Resistance — Use in stationary industrial systems — to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Resistance — Use on ships/at sea — to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna)
Resistance — Use on ships/at sea — to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Resistance — Use on ships/at sea — to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Resistance — Usage in industrial process technology — Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
Resistance — Usage in industrial process technology — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Resistance — Remark — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating — Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Conformal coating — Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Conformal coating — Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Conformal coating — Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A

Configuration

Programming — Programming language — LADYes; incl. failsafe
Programming — Programming language — FBDYes; incl. failsafe
Programming — Programming language — STLYes
Programming — Programming language — SCLYes
Programming — Programming language — CFCYes; either CFC or failsafe functionality
Programming — Programming language — GRAPHYes
Know-how protection — User program protection/password protectionYes
Know-how protection — Copy protectionNo
Know-how protection — Block protectionYes
Access protection — protection of confidential configuration dataYes
Access protection — Password for displayYes
Access protection — Protection level: Write protectionYes
Access protection — Protection level: Read/write protectionYes
Access protection — Protection level: Write protection for FailsafeYes
Access protection — Protection level: Complete protectionYes
Access protection — User administrationYes
Cycle time monitoring — lower limitadjustable minimum cycle time
Cycle time monitoring — upper limitadjustable maximum cycle time

Dimensions

Width210 mm
Height147 mm
Depth129 mm

Weights

Weight, approx.2 116 g

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

6AG1518-4JP00-4AB0: frequently asked questions

When can 6AG1518-4JP00-4AB0 be shipped?

6AG1518-4JP00-4AB0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 6AG1518-4JP00-4AB0 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 6AG1518-4JP00-4AB0 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6AG1518-4JP00-4AB0, subject to availability and destination.

More Siemens parts

Siemens 6AG1516-3FP03-2AB0 – SIPLUS S7-1500 CPU 1516F-3 PN based on 6ES7516-3FP03-0AB0 with conformal coating -40...+60 °C . central…
Siemens
6AG1516-3FP03-2AB0

SIPLUS S7-1500 CPU 1516F-3 PN based on 6ES7516-3FP03-0AB0…

Siemens 6AG1540-1AD00-7AA0 – SIPLUS S7-1500 CM PTP RS-232 BA based on 6ES7540-1AD00-0AA0 with conformal coating, -40…+70 °C
Siemens
6AG1540-1AD00-7AA0

SIPLUS S7-1500 CM PTP RS-232 BA based on 6ES7540-1AD00-0AA0…

Siemens 6AG1540-1AD01-7AA0 – SIPLUS S7-1500 CM PTP RS232 BA based on 6ES7540-1AD01-0AA0 with conformal coating
Siemens
6AG1540-1AD01-7AA0

SIPLUS S7-1500 CM PTP RS232 BA based on 6ES7540-1AD01-0AA0…

Siemens 6AG1591-1AB00-2AA0 – SIPLUS S7-1500 display module CPUs 35 mm based on 6ES7591-1AB00-0AA0 with conformal coating, -40…+60 °C
Siemens
6AG1591-1AB00-2AA0

SIPLUS S7-1500 display module CPUs 35 mm based on…

Siemens 6AG1518-4JP00-4AB0Price and lead time confirmed within 1 business day
Request a Quote