Siemens 6AG1214-1BG40-4XB0

SIPLUS S7-1200 CPU 1214C AC/DC/relay based on 6ES7214-1BG40-0XB0 with conformal coating, -20…+60 °C

MPN
6AG1214-1BG40-4XB0
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Siemens parts? We buy surplus →

What is the Siemens 6AG1214-1BG40-4XB0?

SIPLUS S7-1200 CPU 1214C AC/DC/relay based on 6ES7214-1BG40-0XB0 with conformal coating, -20…+60 °C, compact CPU, AC/DC/relay, onboard I/O: 14 DI 24 V DC 10 DQ relay 2 A 2 AI 0-10 V DC, power supply: AC 85-264 V AC @ 47-63 Hz, program/data memory 100 KB

Specifications

General information

Product type designationCPU 1214C AC/DC/relay
Firmware versionV4.1
based on6ES7214-1BG40-0XB0
Engineering with — STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275

Supply voltage

Rated value (AC) — 120 V ACYes
Rated value (AC) — 230 V ACYes
permissible range, lower limit (AC)85 V
permissible range, upper limit (AC)264 V
Line frequency — permissible range, lower limit47 Hz
Line frequency — permissible range, upper limit63 Hz

Input current

Current consumption (rated value)100 mA at 120 V AC; 50 mA at 240 V AC
Current consumption, max.300 mA at 120 V AC; 150 mA at 240 V AC
Inrush current, max.20 A; at 264 V
I²t0.8 A²·s

Output current

for backplane bus (5 V DC), max.1 600 mA; Max. 5 V DC for SM and CM

Encoder supply

24 V encoder supply — 24 V20.4 to 28.8V

Power loss

Power loss, typ.14 W

Storage

Work memory — integrated100 kbyte
Load memory — integrated4 Mbyte
Load memory — Plug-in (SIMATIC Memory Card), max.with SIMATIC memory card
Backup — presentYes
Backup — maintenance-freeYes
Backup — without batteryYes

CPU processing times

for bit operations, typ.0.08 µs; / instruction
for word operations, typ.1.7 µs; / instruction
for floating point arithmetic, typ.2.3 µs; / instruction

CPU-blocks

Number of blocks (total)DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used
Number of elements (total)DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used
OB — Number, max.Limited only by RAM for code

Data areas and their retentivity

Retentive data area (incl. timers, counters, flags), max.10 kbyte
Flag — Size, max.8 kbyte; Size of bit memory address area
Local data — per priority class, max.16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB

Address area

Process image — Inputs, adjustable1 kbyte
Process image — Outputs, adjustable1 kbyte

Hardware configuration

Number of modules per system, max.3 comm. modules, 1 signal board, 8 signal modules
Number of modules per system, max. — number of expansion boards (SB, CB, BB)1
Number of modules per system, max. — number of signal modules (SM)8
Number of modules per system, max. — number of communications modules (CM)3

Time of day

Clock — Hardware clock (real-time)Yes
Clock — Backup time480 h; Typical
Clock — Deviation per day, max.±60 s/month at 25 °C

Digital inputs

Number of digital inputs14; Integrated
Number of digital inputs — of which inputs usable for technological functions6; HSC (High Speed Counting)
Sourcing/sinking inputYes
Number of simultaneously controllable inputs — all mounting positions — up to 40 °C, max.14
Input voltage — Rated value (DC)24 V
Input voltage — for signal "0"5 V DC at 1 mA
Input voltage — for signal "1"15 V DC at 2.5 mA
Input delay (for rated value of input voltage) — for standard inputs — Parameterizable0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms
Input delay (for rated value of input voltage) — for standard inputs — at "0" to "1", min.0.2 ms
Input delay (for rated value of input voltage) — for standard inputs — at "0" to "1", max.12.8 ms
Input delay (for rated value of input voltage) — for interrupt inputs — ParameterizableYes
Input delay (for rated value of input voltage) — for technological functions — ParameterizableSingle phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz
Cable length — shielded, max.500 m; 50 m for technological functions
Cable length — unshielded, max.300 m; for technological functions: No

Digital outputs

Number of digital outputs10; Relays
Switching capacity of the outputs — with resistive load, max.2 A
Switching capacity of the outputs — on lamp load, max.30 W with DC, 200 W with AC
Output delay with resistive load — "0" to "1", max.10 ms; max.
Output delay with resistive load — "1" to "0", max.10 ms; max.
Relay outputs — Number of relay outputs10
Relay outputs — Number of operating cycles, max.mechanically 10 million, at rated load voltage 100 000
Cable length — shielded, max.500 m
Cable length — unshielded, max.150 m

Analog inputs

Number of analog inputs2
Input ranges — VoltageYes
Input ranges (rated values), voltages — 0 to +10 VYes
Input ranges (rated values), voltages — 0 to +10 V — Input resistance (0 to 10 V)≥100k ohms
Cable length — shielded, max.100 m; twisted and shielded

Analog outputs

Number of analog outputs0

Analog value generation for the inputs

Integration and conversion time/resolution per channel — Resolution with overrange (bit including sign), max.10 bit
Integration and conversion time/resolution per channel — Integration time, parameterizableYes
Integration and conversion time/resolution per channel — Conversion time (per channel)625 µs

Encoder

Connectable encoders — 2-wire sensorYes

Interfaces

Number of PROFINET interfaces1

1. Interface

Interface typePROFINET
IsolatedYes
automatic detection of transmission rateYes
AutonegotiationYes
AutocrossingYes
Interface types — RJ 45 (Ethernet)Yes
Interface types — Number of ports1
Interface types — integrated switchNo
Protocols — PROFINET IO ControllerYes
Protocols — PROFINET IO DeviceYes
Protocols — SIMATIC communicationYes
Protocols — Open IE communicationYes; Optionally also encrypted
Protocols — Web serverYes
Protocols — Media redundancyNo
PROFINET IO Controller — Transmission rate, max.100 Mbit/s
PROFINET IO Controller — Services — PG/OP communicationYes; encryption with TLS V1.3 pre-selected
PROFINET IO Controller — Services — Isochronous modeNo
PROFINET IO Controller — Services — IRTNo
PROFINET IO Controller — Services — PROFIenergyNo
PROFINET IO Controller — Services — Prioritized startupYes
PROFINET IO Controller — Services — Number of IO devices with prioritized startup, max.16
PROFINET IO Controller — Services — Number of connectable IO Devices, max.16
PROFINET IO Controller — Services — Number of connectable IO Devices for RT, max.16
PROFINET IO Controller — Services — of which in line, max.16
PROFINET IO Controller — Services — Number of IO Devices that can be simultaneously activated/deactivated, max.8
PROFINET IO Controller — Services — Updating timeThe minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
PROFINET IO Device — Services — PG/OP communicationYes; encryption with TLS V1.3 pre-selected
PROFINET IO Device — Services — Isochronous modeNo
PROFINET IO Device — Services — IRTNo
PROFINET IO Device — Services — Dynamic Frame Packing (DFP)No
PROFINET IO Device — Services — PROFIenergyYes
PROFINET IO Device — Services — Prioritized startupYes
PROFINET IO Device — Services — Shared deviceYes
PROFINET IO Device — Services — Number of IO Controllers with shared device, max.2
PROFINET IO Device — Services — Asset management recordYes

Protocols

PROFINET IOYes
PROFIsafeNo
PROFIBUSYes; CM 1243-5 (master) or CM 1242-5 (slave) required
OPC UAYes; OPC UA Server
AS-InterfaceYes; CM 1243-2 required
Protocols (Ethernet) — TCP/IPYes
Protocols (Ethernet) — DHCPNo
Protocols (Ethernet) — SNMPYes
Protocols (Ethernet) — DCPYes
Protocols (Ethernet) — LLDPYes
Redundancy mode — PROFINET system redundancy (S2)No
Redundancy mode — PROFINET system redundancy (R1)No
Redundancy mode — Media redundancy — MRPNo
Redundancy mode — Media redundancy — MRP interconnection, supportedNo
Redundancy mode — Media redundancy — MRPDNo
SIMATIC communication — S7 routingYes
Open IE communication — TCP/IPYes
Open IE communication — TCP/IP — Data length, max.8 kbyte
Open IE communication — ISO-on-TCP (RFC1006)Yes
Open IE communication — ISO-on-TCP (RFC1006) — Data length, max.8 kbyte
Open IE communication — UDPYes
Open IE communication — UDP — Data length, max.1 472 byte
Web server — supportedYes
Web server — User-defined websitesYes
OPC UA — Runtime license requiredYes; "Basic" license required
OPC UA — OPC UA ServerYes; data access (read, write, subscribe), method call, runtime license required
OPC UA — OPC UA Server — Application authenticationAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
OPC UA — OPC UA Server — User authentication"anonymous" or by user name & password
OPC UA — OPC UA Server — Number of sessions, max.10
OPC UA — OPC UA Server — Number of subscriptions per session, max.5
OPC UA — OPC UA Server — Sampling interval, min.100 ms
OPC UA — OPC UA Server — Publishing interval, min.200 ms
OPC UA — OPC UA Server — Number of server methods, max.20
OPC UA — OPC UA Server — Number of monitored items, recommended max.1 000
OPC UA — OPC UA Server — Number of server interfaces, max.2
OPC UA — OPC UA Server — Number of nodes for user-defined server interfaces, max.2 000
Further protocols — MODBUSYes

Communication functions

S7 communication — supportedYes
S7 communication — as serverYes
S7 communication — as clientYes
S7 communication — User data per job, max.See online help (S7 communication, user data size)
Number of connections — overallPG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 68 max
Number of connections — overallPG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 68 max

Test commissioning functions

Status/control — Status/control variableYes
Status/control — VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Forcing — ForcingYes
Diagnostic buffer — presentYes
Traces — Number of configurable Traces2
Traces — Memory size per trace, max.512 kbyte

Interrupts/diagnostics/status information

Diagnostics indication LED — RUN/STOP LEDYes
Diagnostics indication LED — ERROR LEDYes
Diagnostics indication LED — MAINT LEDYes

Integrated Functions

Counter — Number of counters6
Counter — Counting frequency, max.100 kHz
Frequency measurementYes
controlled positioningYes
Number of position-controlled positioning axes, max.8
Number of positioning axes via pulse-direction interfaceUp to 4 with SB 1222
PID controllerYes
Number of alarm inputs4

Potential separation

Potential separation digital inputs — Potential separation digital inputs500 V AC for 1 minute
Potential separation digital inputs — between the channels, in groups of1
Potential separation digital outputs — Potential separation digital outputsRelays
Potential separation digital outputs — between the channelsNo
Potential separation digital outputs — between the channels, in groups of2

EMC

Interference immunity against discharge of static electricity — Interference immunity against discharge of static electricity acc. to IEC 61000-4-2Yes
Interference immunity against discharge of static electricity — Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 — Test voltage at air discharge8 kV
Interference immunity against discharge of static electricity — Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 — Test voltage at contact discharge6 kV
Interference immunity to cable-borne interference — Interference immunity on supply lines acc. to IEC 61000-4-4Yes
Interference immunity to cable-borne interference — Interference immunity on signal cables acc. to IEC 61000-4-4Yes
Interference immunity against voltage surge — Interference immunity on supply lines acc. to IEC 61000-4-5Yes
Interference immunity against conducted variable disturbance induced by high-frequency fields — Interference immunity against high-frequency radiation acc. to IEC 61000-4-6Yes
Emission of radio interference acc. to EN 55 011 — Limit class A, for use in industrial areasYes; Group 1
Emission of radio interference acc. to EN 55 011 — Limit class B, for use in residential areasYes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011

Degree and class of protection

IP degree of protectionIP20

Ambient conditions

Free fall — Fall height, max.0.3 m; five times, in product package
Ambient temperature during operation — min.-20 °C; = Tmin (incl. condensation/frost); start-up @ 0 °C
Ambient temperature during operation — max.60 °C; = Tmax; Tmax > +55 °C number of simultaneously switched-on digital inputs 7, digital outputs 5, analog inputs 2 (no adjacent points) with horizontal mounting position
Ambient temperature during operation — At cold restart, min.0 °C
Ambient temperature during storage/transportation — min.-40 °C
Ambient temperature during storage/transportation — max.70 °C
Altitude during operation relating to sea level — Installation altitude above sea level, max.2 000 m
Altitude during operation relating to sea level — Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m); above 2 000 m max. 132 V AC
Relative humidity — With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Vibrations — Vibration resistance during operation acc. to IEC 60068-2-62 g (m/s²) wall mounting, 1 g (m/s²) DIN rail
Vibrations — Operation, tested according to IEC 60068-2-6Yes
Shock testing — tested according to IEC 60068-2-27Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms
Resistance — Coolants and lubricants — Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Resistance — Use in stationary industrial systems — to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
Resistance — Use in stationary industrial systems — to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Resistance — Use in stationary industrial systems — to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Resistance — Use on ships/at sea — to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
Resistance — Use on ships/at sea — to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Resistance — Use on ships/at sea — to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Resistance — Usage in industrial process technology — Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
Resistance — Usage in industrial process technology — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Resistance — Remark — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating — Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Conformal coating — Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Conformal coating — Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Conformal coating — Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A

Configuration

Programming — Programming language — LADYes
Programming — Programming language — FBDYes
Programming — Programming language — SCLYes
Know-how protection — User program protection/password protectionYes
Know-how protection — Copy protectionYes
Know-how protection — Block protectionYes
Access protection — protection of confidential configuration dataYes
Access protection — Protection level: Write protectionYes
Access protection — Protection level: Read/write protectionYes
Access protection — Protection level: Complete protectionYes
Access protection — User administrationYes; device-wide
Access protection — Number of users42
Access protection — Number of groups14
Access protection — Number of roles20
Cycle time monitoring — adjustableYes

Dimensions

Width110 mm
Height100 mm
Depth75 mm

Weights

Weight, approx.455 g

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

6AG1214-1BG40-4XB0: frequently asked questions

When can 6AG1214-1BG40-4XB0 be shipped?

6AG1214-1BG40-4XB0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 6AG1214-1BG40-4XB0 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 6AG1214-1BG40-4XB0 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6AG1214-1BG40-4XB0, subject to availability and destination.

More Siemens parts

Siemens 6AG1221-1BF32-2XB0 – SIPLUS S7-1200 SM 1221 8DI based on 6ES7221-1BF32-0XB0 with conformal coating, -40…+70 °C, start up -25 °C
Siemens
6AG1221-1BF32-2XB0

SIPLUS S7-1200 SM 1221 8DI based on 6ES7221-1BF32-0XB0 with…

Siemens 6AG1221-1BF32-4XB0 – SIPLUS S7-1200 SM 1221 8DI based on 6ES7221-1BF32-0XB0 with conformal coating, -20…+60 °C, digital input 8 DI
Siemens
6AG1221-1BF32-4XB0

SIPLUS S7-1200 SM 1221 8DI based on 6ES7221-1BF32-0XB0 with…

Siemens 6AG1221-1BH32-2XB0 – SIPLUS S7-1200 SM 1221 16DI based on 6ES7221-1BH32-0XB0 with conformal coating, -40…+70 °C, start up -25 °C
Siemens
6AG1221-1BH32-2XB0

SIPLUS S7-1200 SM 1221 16DI based on 6ES7221-1BH32-0XB0…

Siemens 6AG1214-1BG40-4XB0Price and lead time confirmed within 1 business day
Request a Quote