Siemens 3VA2463-5HN32-0KJ0

Circuit breaker 3VA2 IEC Frame 630 breaking capacity class M Icu=55 kA @ 415 V 3-pole, line protection ETU350

MPN
3VA2463-5HN32-0KJ0
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Siemens parts? We buy surplus →

What is the Siemens 3VA2463-5HN32-0KJ0?

circuit breaker 3VA2 IEC Frame 630 breaking capacity class M Icu=55 kA @ 415 V 3-pole, line protection ETU350, LSI, In=630 A overload protection Ir=250 A...630 A short-circuit protection Isd=1.5...9x Ir, Ii=9x In nut keeper kit circuit breaker 3VA2 IEC Frame 630 breaking capacity class M Icu=55 kA @ 415 V shunt trip left, 208-277 V AC 50/60 Hz 2 auxiliary switches HP 1 trip alarm switch HP

Specifications

Model

product brand nameSENTRON
product designationMolded case circuit breaker
design of the productLine protection
design of the overcurrent releaseETU350
protection function of the overcurrent releaseLSI
number of poles3
design of the auxiliary releaseshunt trip (STL)
design of the auxiliary switch2 auxiliary switches + 1 trip alarm switch HP

General technical data

insulation voltage / rated value800 V
operating voltage / at AC / rated value690 V
power loss [W] / maximum162 W
power loss [W] / for rated value of the current / at AC / in hot operating state / per pole54 W
mechanical service life (operating cycles) / typical20 000
electrical endurance (operating cycles) / at AC-1 / at 380/415 V5 000
electrical endurance (operating cycles) / at AC-1 / at 690 V3 500
product feature / for neutral conductors / upgradable/retrofittable / short-circuit and overload proofNo
ground-fault monitoring versionWithout
product function — communication functionNo
product function — other measurement functionNo
Net Weight5.386 kg

Current

operational current — at 40 °C630 A
operational current — at 45 °C612 A
operational current — at 50 °C593 A
operational current — at 55 °C575 A
operational current — at 60 °C557 A
operational current — at 65 °C538 A
operational current — at 70 °C520 A

Switching capacity according to IEC 60947

switching capacity class of the circuit breakerM
maximum short-circuit current breaking capacity (Icu) — at 240 V85 kA
maximum short-circuit current breaking capacity (Icu) — at 415 V55 kA
maximum short-circuit current breaking capacity (Icu) — at 440 V55 kA
maximum short-circuit current breaking capacity (Icu) — at 500 V36 kA
maximum short-circuit current breaking capacity (Icu) — at 690 V6 kA
operating short-circuit current breaking capacity (Ics) — at 240 V85 kA
operating short-circuit current breaking capacity (Ics) — at 415 V55 kA
operating short-circuit current breaking capacity (Ics) — at 440 V55 kA
operating short-circuit current breaking capacity (Ics) — at 500 V36 kA
operating short-circuit current breaking capacity (Ics) — at 690 V6 kA
short-circuit current making capacity (Icm) — at 240 V187 kA
short-circuit current making capacity (Icm) — at 415 V121 kA
short-circuit current making capacity (Icm) — at 440 V121 kA
short-circuit current making capacity (Icm) — at 500 V75.6 kA
short-circuit current making capacity (Icm) — at 690 V9 kA

Adjustable parameters

product feature / for L-tripping / can be switched on/offNo
adjustable response value setting current (Ir) / of the L-trip / with I2t characteristic — minimum250 A
adjustable response value setting current (Ir) / of the L-trip / with I2t characteristic — maximum630 A
adjustable response value delay time (tr) / for L-tripping / with I2t characteristic — minimum0.5 s
adjustable response value delay time (tr) / for L-tripping / with I2t characteristic — maximum12 s
adjustable response value setting current (Isd) / of S-trip / with I2t characteristic — minimum375 A
adjustable response value setting current (Isd) / of S-trip / with I2t characteristic — maximum5 670 A
adjustable response value delay time (tsd) / for S-tripping / with I2t characteristic — minimum0.0001 s
adjustable response value delay time (tsd) / for S-tripping / with I2t characteristic — maximum0.4 s
adjustable response value setting current (Ii) / for I-tripping — minimum5 670 A
adjustable response value setting current (Ii) / for I-tripping — maximum5 670 A
adjustable setting current (InN) / for N-tripping — minimum0 A
adjustable setting current (InN) / for N-tripping — maximum0 A
product function / grounding protectionNo

Mechanical Design

product component — undervoltage releaseNo
product component — voltage triggerYes
product component — trip indicatorYes
height [in]9.76 in
height248 mm
width [in]5.43 in
width138 mm
depth [in]4.33 in
depth110 mm

Connections

arrangement of electrical connectors / for main current circuitFront terminal
type of electrical connection / for main current circuiton both sides nut keeper kit
type of connectable conductor cross-sections / for flat-bar terminal connection / minimum20 x 1 mm
type of connectable conductor cross-sections / for flat-bar terminal connection / maximum35 x 10 mm
design of the surface / of the connections / on the top of the switch (N, 1, 3, 5)silver
design of the surface / of the connections / on the bottom of the switch (N, 2, 4, 6)silver

Auxiliary circuit

number of CO contacts / for auxiliary contacts3

Accessories

product extension / optional / motor driveYes
manufacturer's article number — of the supplied basic switch#BEZUG!
manufacturer's article number — of the integrated auxiliary switch/alarm switch3VA9988-0AA11
manufacturer's article number — of the integrated auxiliary switch/alarm switch3VA9988-0AB11
manufacturer's article number — of the integrated auxiliary trip unit3VA9688-0BL33

Environmental conditions

protection class IP / on the frontIP40
ambient temperature — during operation / minimum-25 °C
ambient temperature — during operation / maximum70 °C
ambient temperature — during storage / minimum-40 °C
ambient temperature — during storage / maximum80 °C
reference code / according to IEC 81346-2Q

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

3VA2463-5HN32-0KJ0: frequently asked questions

When can 3VA2463-5HN32-0KJ0 be shipped?

3VA2463-5HN32-0KJ0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 3VA2463-5HN32-0KJ0 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 3VA2463-5HN32-0KJ0 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 3VA2463-5HN32-0KJ0, subject to availability and destination.

More Siemens parts

Siemens 3VA2463-5HL32-0AA0 – Circuit breaker 3VA2 IEC Frame 630 breaking capacity class M Icu=55 kA @ 415 V 3-pole, line protection ETU320
Siemens
3VA2463-5HL32-0AA0

Circuit breaker 3VA2 IEC Frame 630 breaking capacity class…

Siemens 3VA2463-5HL42-0AA0 – Circuit breaker 3VA2 IEC Frame 630 breaking capacity class M Icu=55 kA @ 415 V 4-pole, line protection ETU320
Siemens
3VA2463-5HL42-0AA0

Circuit breaker 3VA2 IEC Frame 630 breaking capacity class…

Siemens 3VA2463-5HM42-0AA0 – Circuit breaker 3VA2 IEC Frame 630 breaking capacity class M Icu=55 kA @ 415 V 4-pole, line protection ETU330
Siemens
3VA2463-5HM42-0AA0

Circuit breaker 3VA2 IEC Frame 630 breaking capacity class…

Siemens 3VA2463-5HN32-0AA0 – Circuit breaker 3VA2 IEC Frame 630 breaking capacity class M Icu=55 kA @ 415 V 3-pole, line protection ETU350
Siemens
3VA2463-5HN32-0AA0

Circuit breaker 3VA2 IEC Frame 630 breaking capacity class…

Siemens 3VA2463-5HN42-0AA0 – Circuit breaker 3VA2 IEC Frame 630 breaking capacity class M Icu=55 kA @ 415 V 4-pole, line protection ETU350
Siemens
3VA2463-5HN42-0AA0

Circuit breaker 3VA2 IEC Frame 630 breaking capacity class…

Siemens 3VA2463-5JP32-0AA0 – Circuit breaker 3VA2 IEC Frame 630 breaking capacity class M Icu=55 kA @ 415 V 3-pole, line protection ETU550
Siemens
3VA2463-5JP32-0AA0

Circuit breaker 3VA2 IEC Frame 630 breaking capacity class…

Siemens 3VA2463-5KP32-0AA0 – Circuit breaker 3VA2 IEC Frame 630 breaking capacity class M Icu=55 kA @ 415 V 3-pole, line protection ETU850
Siemens
3VA2463-5KP32-0AA0

Circuit breaker 3VA2 IEC Frame 630 breaking capacity class…

Siemens 3VA2463-5KQ32-0AA0 – Circuit breaker 3VA2 IEC Frame 630 breaking capacity class M Icu=55 kA @ 415 V 3-pole, line protection ETU860
Siemens
3VA2463-5KQ32-0AA0

Circuit breaker 3VA2 IEC Frame 630 breaking capacity class…

Siemens 3VA2463-5HN32-0KJ0Price and lead time confirmed within 1 business day
Request a Quote