Siemens 3RT2526-1AV60

Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 480 V AC, 60 Hz, main contacts: 2 NO + 2 NC

MPN
3RT2526-1AV60
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Siemens parts? We buy surplus →

What is the Siemens 3RT2526-1AV60?

power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 480 V AC, 60 Hz, main contacts: 2 NO + 2 NC, auxiliary contacts: 1 NO + 1 NC, screw terminal, frame size: S0

Specifications

General technical data

size of contactorS0
product extension – function module for communicationNo
product extension – auxiliary switchYes
power loss [W] for rated value of the current – at AC in hot operating state per pole1.9 W
power loss [W] for rated value of the current – without load current share typical2.7 W
type of calculation of power loss current-dependentquadratic
insulation voltage – of main circuit with degree of pollution 3 rated value690 V
insulation voltage – of auxiliary circuit with degree of pollution 3 rated value690 V
surge voltage resistance – of main circuit rated value6 kV
surge voltage resistance – of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1400 V
shock resistance at rectangular impulse – at AC8,3 g / 5 ms, 5,3 g / 10 ms
shock resistance with sine pulse – at AC13,5 g / 5 ms, 8,3 g / 10 ms
mechanical service life (operating cycles) – of contactor typical10 000 000
mechanical service life (operating cycles) – of the contactor with added electronically optimized auxiliary switch block typical5 000 000
mechanical service life (operating cycles) – of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)10/01/2009
Net Weight0.448 kg

Ambient conditions

installation altitude at height above sea level maximum2 000 m
ambient temperature – during operation-25 ... +60 °C
ambient temperature – during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %

Main circuit

number of poles for main current circuit4
number of NO contacts for main contacts2
number of NC contacts for main contacts2
at AC-1 up to 690 V – — at ambient temperature 40 °C rated value40 A
at AC-1 up to 690 V – — at ambient temperature 60 °C rated value35 A
at AC-2 at AC-3 at 400 V – — per NO contact rated value25 A
at AC-2 at AC-3 at 400 V – — per NC contact rated value25 A
minimum cross-section in main circuit at maximum AC-1 rated value10 mm²
at 1 current path at DC-1 – — at 24 V rated value35 A
at 1 current path at DC-1 – — at 110 V rated value4.5 A
at 1 current path at DC-1 – — at 220 V rated value1 A
at 1 current path at DC-1 – — at 440 V rated value0.4 A
with 2 current paths in series at DC-1 – — at 24 V rated value35 A
with 2 current paths in series at DC-1 – — at 110 V rated value35 A
with 2 current paths in series at DC-1 – — at 220 V rated value5 A
with 2 current paths in series at DC-1 – — at 440 V rated value1 A
at 1 current path at DC-3 at DC-5 – — at 24 V per NC contact rated value20 A
at 1 current path at DC-3 at DC-5 – — at 24 V per NO contact rated value20 A
at 1 current path at DC-3 at DC-5 – — at 110 V per NC contact rated value1.25 A
at 1 current path at DC-3 at DC-5 – — at 110 V per NO contact rated value2.5 A
at 1 current path at DC-3 at DC-5 – — at 220 V per NC contact rated value0.5 A
at 1 current path at DC-3 at DC-5 – — at 220 V per NO contact rated value1 A
at 1 current path at DC-3 at DC-5 – — at 440 V per NC contact rated value0.045 A
at 1 current path at DC-3 at DC-5 – — at 440 V per NO contact rated value0.09 A
with 2 current paths in series at DC-3 at DC-5 – — at 24 V per NC contact rated value35 A
with 2 current paths in series at DC-3 at DC-5 – — at 24 V per NO contact rated value35 A
with 2 current paths in series at DC-3 at DC-5 – — at 110 V per NC contact rated value7.5 A
with 2 current paths in series at DC-3 at DC-5 – — at 110 V per NO contact rated value15 A
with 2 current paths in series at DC-3 at DC-5 – — at 220 V per NC contact rated value1.5 A
with 2 current paths in series at DC-3 at DC-5 – — at 220 V per NO contact rated value3 A
with 2 current paths in series at DC-3 at DC-5 – — at 440 V per NC contact rated value0.135 A
with 2 current paths in series at DC-3 at DC-5 – — at 440 V per NO contact rated value0.27 A
operating power at AC-2 at AC-3 – at 230 V per NC contact rated value5.5 kW
operating power at AC-2 at AC-3 – at 230 V per NO contact rated value5.5 kW
operating power at AC-2 at AC-3 – at 400 V per NC contact rated value11 kW
operating power at AC-2 at AC-3 – at 400 V per NO contact rated value11 kW
short-time withstand current in cold operating state up to 40 °C – limited to 1 s switching at zero current maximum200 A; Use minimum cross-section acc. to AC-1 rated value
short-time withstand current in cold operating state up to 40 °C – limited to 5 s switching at zero current maximum200 A; Use minimum cross-section acc. to AC-1 rated value
short-time withstand current in cold operating state up to 40 °C – limited to 10 s switching at zero current maximum200 A; Use minimum cross-section acc. to AC-1 rated value
short-time withstand current in cold operating state up to 40 °C – limited to 30 s switching at zero current maximum128 A; Use minimum cross-section acc. to AC-1 rated value
short-time withstand current in cold operating state up to 40 °C – limited to 60 s switching at zero current maximum106 A; Use minimum cross-section acc. to AC-1 rated value
power loss [W] at AC-3 at 400 V for rated value of the operational current per conductor1.9 W
power loss [W] at AC-3e at 400 V for rated value of the operational current per conductor1.9 W
no-load switching frequency – at AC5 000 1/h
no-load switching frequency – at DC1 500 1/h
operating frequency – at AC-1 maximum1 000 1/h

Control circuit/ Control

type of voltage of the control supply voltageAC
control supply voltage at AC – at 60 Hz rated value480 V
operating range factor control supply voltage rated value of magnet coil at AC – at 60 Hz0.8 ... 1.1
apparent pick-up power of magnet coil at AC87 V·A
at 60 Hz87 V·A
inductive power factor with closing power of the coil0.82
at 60 Hz0.76
apparent holding power of magnet coil at AC9.8 V·A
at 60 Hz9.4 V·A
inductive power factor with the holding power of the coil0.25
at 60 Hz0.28
closing delay – at AC8 ... 40 ms
opening delay – at AC4 ... 16 ms
arcing time10 ms
residual current of the electronics for control with signal <0> – at AC at 230 V maximum permissible0 A

Auxiliary circuit

number of NC contacts for auxiliary contacts instantaneous contact1
number of NO contacts for auxiliary contacts instantaneous contact1
operational current at AC-12 maximum10 A
operational current at AC-15 – at 230 V rated value10 A
operational current at AC-15 – at 400 V rated value3 A
operational current at AC-15 – at 500 V rated value2 A
operational current at AC-15 – at 690 V rated value1 A
operational current at DC-12 – at 24 V rated value10 A
operational current at DC-12 – at 48 V rated value6 A
operational current at DC-12 – at 60 V rated value6 A
operational current at DC-12 – at 110 V rated value3 A
operational current at DC-12 – at 125 V rated value2 A
operational current at DC-12 – at 220 V rated value1 A
operational current at DC-12 – at 600 V rated value0.15 A
operational current at DC-13 – at 24 V rated value10 A
operational current at DC-13 – at 48 V rated value2 A
operational current at DC-13 – at 60 V rated value2 A
operational current at DC-13 – at 110 V rated value1 A
operational current at DC-13 – at 125 V rated value0.9 A
operational current at DC-13 – at 220 V rated value0.3 A
operational current at DC-13 – at 600 V rated value0.1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)

UL/CSA ratings

yielded mechanical performance [hp] – for single-phase AC motor at 230 V rated value3 hp
yielded mechanical performance [hp] – for 3-phase AC motor at 460/480 V rated value15 hp
contact rating of auxiliary contacts according to ULA600 / Q600
UL File Number (CCN)E31519 (NLDX, NLDX7)

Short-circuit protection

design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
for short-circuit protection of the main circuit – — with type of coordination 1 requiredgG: 63 A (690 V, 100 kA)
for short-circuit protection of the main circuit – — with type of coordination 2 requiredgG: 35 A (690 V, 50 kA)
for short-circuit protection of the main circuit – for short-circuit protection of the auxiliary switch requiredgG: 10 A (690 V, 1 kA)

Installation/ mounting/ dimensions

mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
height85 mm
width61 mm
depth97 mm
with side-by-side mounting – — forwards0 mm
with side-by-side mounting – — backwards0 mm
with side-by-side mounting – — upwards0 mm
with side-by-side mounting – — downwards0 mm
with side-by-side mounting – — at the side0 mm
for grounded parts – — forwards0 mm
for grounded parts – — backwards0 mm
for grounded parts – — upwards0 mm
for grounded parts – — at the side6 mm
for grounded parts – — downwards0 mm
for live parts – — forwards0 mm
for live parts – — backwards0 mm
for live parts – — upwards0 mm
for live parts – — downwards0 mm
for live parts – — at the side6 mm

Connections/ Terminals

type of electrical connection – for main current circuitscrew-type terminals
type of electrical connection – for auxiliary and control circuitscrew-type terminals
type of electrical connection – at contactor for auxiliary contactsScrew-type terminals
type of electrical connection – of magnet coilscrew terminal
for main contacts – — solid2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
for main contacts – — solid or stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
for main contacts – — finely stranded with core end processing2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
for main contacts – for AWG cables for main contacts2x (16 ... 12), 2x (14 ... 8)
for auxiliary contacts – — solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for auxiliary contacts – — solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for auxiliary contacts – — finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for auxiliary contacts – for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)
AWG number as coded connectable conductor cross section for main contacts16 ... 8
AWG number as coded connectable conductor cross section for auxiliary contacts20 ... 14

Safety related data

product function – mirror contact according to IEC 60947-4-1Yes
product function – positively driven operation according to IEC 60947-5-1No
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

3RT2526-1AV60: frequently asked questions

When can 3RT2526-1AV60 be shipped?

3RT2526-1AV60 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 3RT2526-1AV60 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 3RT2526-1AV60 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 3RT2526-1AV60, subject to availability and destination.

More Siemens parts

Siemens 3RT2526-1AF00 – Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 110 V AC, 50 Hz, main contacts: 2 NO + 2 NC
Siemens
3RT2526-1AF00

Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole

Siemens 3RT2526-1AG20 – Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 110 V AC, 50/60 Hz, main contacts: 2 NO + 2 NC
Siemens
3RT2526-1AG20

Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole

Siemens 3RT2526-1AH20 – Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 48 V AC, 50/60 Hz, main contacts: 2 NO + 2 NC
Siemens
3RT2526-1AH20

Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 48 V AC

Siemens 3RT2526-1AK60 – Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 110 V AC, 50 Hz / 120 V, 60 Hz
Siemens
3RT2526-1AK60

Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole

Siemens 3RT2526-1BA40 – Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 12 V DC, main contacts: 2 NO + 2 NC
Siemens
3RT2526-1BA40

Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 12 V DC

Siemens 3RT2526-1BB40 – Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 24 V DC, main contacts: 2 NO + 2 NC
Siemens
3RT2526-1BB40

Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 24 V DC

Siemens 3RT2526-1BE40 – Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 60 V DC, main contacts: 2 NO + 2 NC
Siemens
3RT2526-1BE40

Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 60 V DC

Siemens 3RT2526-1BF40 – Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole, 110 V DC, main contacts: 2 NO + 2 NC
Siemens
3RT2526-1BF40

Power contactor, AC-3, 25 A, 11 kW / 400 V, 4-pole