What is the Siemens 3RK1315-6LS41-1AA5?
SIRIUS motor starter M200D AS-i communication: AS-Interface reversing starter basic mechanical switching AC-3, 5.5 kW / 400 V 1.5 A...12.00 A electronic overload protection thermistor: thermoclick / PTC with brake contact 180 V DC 2 DI AS-i + 2 DI / 1 DO on device Han Q4/2 - Han Q8/0
Specifications
General
| product brand name | SIRIUS |
| product designation | Motor starters |
| design of the product | reversing starter |
| product type designation | M200D |
| product function — on-site operation | No |
| product function — control circuit interface to parallel wiring | No |
| insulation voltage rated value | 500 V |
| degree of pollution | 3 |
| surge voltage resistance rated value | 6 000 V |
| maximum permissible voltage for protective separation — between main and auxiliary circuit | 400 V |
| maximum permissible voltage for protective separation — between control and auxiliary circuit | 24 V |
| shock resistance | 12 g / 11 ms |
| vibration resistance | 7 mm / 2 g |
| mechanical service life (operating cycles) of the main contacts typical | 10 000 000 |
| type of coordination | 1 |
| Substance Prohibitance (day/month/year) | 07/01/2006 |
| SVHC substance name | Lead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1 |
| Net Weight | 3 kg |
| product function — direct start | No |
| product function — reverse starting | Yes |
| product component motor brake output | Yes |
| product feature — brake control with 230 V AC | No |
| product feature — brake control with 400 V AC | No |
| product feature — brake control with 24 V DC | No |
| product feature — brake control with 180 V DC | Yes |
| product feature — brake control with 500 V DC | No |
| product extension braking module for brake control | No |
| product function short circuit protection | Yes |
| design of short-circuit protection | circuit-breakers |
| maximum short-circuit current breaking capacity (Icu) — at 400 V rated value | 50 000 A |
| maximum short-circuit current breaking capacity (Icu) — at 500 V rated value | 50 000 A |
| EMC emitted interference according to IEC 60947-1 | CISPR11, ambience A (industrial sector) |
| EMC immunity according to IEC 60947-1 | corresponds to degree of severity 3, ambience A (industrial sector) |
| conducted interference — due to burst according to IEC 61000-4-4 | 2 kV network connection / 1 kV control connection |
| conducted interference — due to conductor-earth surge according to IEC 61000-4-5 | 2 kV |
| conducted interference — due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV |
Safety related data
| proportion of dangerous failures — with low demand rate according to SN 31920 | 50 % |
| proportion of dangerous failures — with high demand rate according to SN 31920 | 75 % |
| B10 value with high demand rate according to SN 31920 | 1 000 000 |
| failure rate [FIT] with low demand rate according to SN 31920 | 100 FIT |
| T1 value for proof test interval or service life according to IEC 61508 | 20 a |
| touch protection against electrical shock | finger-safe |
Main circuit
| number of poles for main current circuit | 3 |
| design of the switching contact | electromechanical |
| adjustable current response value current of the current-dependent overload release | 1.5 ... 12 A |
| type of the motor protection | full motor protection |
| operating voltage rated value | 200 ... 440 V |
| operational current — at AC at 400 V rated value | 12 A |
| operational current — at AC-3 at 400 V rated value | 12 A |
| operating power — at AC-3 — at 400 V rated value | 5.5 kW |
| operating power — at AC-3 — at 500 V rated value | 5 500 W |
| operating power — at AC-3e — at 400 V rated value | 6 kW |
| operating power — at AC-3e — at 500 V rated value | 5.5 kW |
| product function — digital inputs parameterizable | No |
| product function — digital outputs parameterizable | No |
| number of digital inputs | 4 |
| number of sockets — for digital output signals | 1 |
| number of sockets — for digital input signals | 4 |
| number of digital outputs | 1 |
Supply voltage
| type of voltage of the supply voltage | DC |
| supply voltage 1 at DC | 24 V |
| supply voltage 1 at DC rated value | 30 V |
| supply voltage 1 at DC rated value — minimum permissible | 26.5 V |
| supply voltage 1 at DC rated value — maximum permissible | 31.6 V |
Control circuit/ Control
| type of voltage of the control supply voltage | DC |
| control supply voltage at DC rated value | 20.4 ... 28.8 V |
| control supply voltage 1 at DC rated value | 24 V |
| control supply voltage 1 at DC rated value | 20.4 ... 28.8 V |
| control supply voltage 1 at DC | 20.4 ... 28.8 V |
| control current at DC — in standby mode of operation | 100 mA |
| control current at DC — during operation | 0.6 A |
| power loss [W] in auxiliary and control circuit — in switching state OFF with bypass circuit | 2.0736 W |
| power loss [W] in auxiliary and control circuit — in switching state ON with bypass circuit | 4.1184 W |
Response times
| ON-delay time | 85 ms |
| OFF-delay time | 65 ms |
| mounting position | vertical, horizontal, flat |
| mounting position recommended | horizontal |
| fastening method | screw fixing |
| height | 215 mm |
| width | 294 mm |
| depth | 159 mm |
Ambient conditions
| installation altitude at height above sea level maximum | 2 000 m |
| ambient temperature — during operation | -25 ... +55 °C |
| ambient temperature — during storage | -40 ... +70 °C |
| ambient temperature — during transport | -40 ... +70 °C |
| relative humidity during operation | 10 ... 95 % |
| protocol is supported — PROFIBUS DP protocol | No |
| protocol is supported — PROFINET protocol | No |
| design of the interface — AS-Interface protocol | Yes |
| design of the interface — PROFINET protocol | No |
| design of the interface — PROFIBUS DP protocol | No |
| product function bus communication | Yes |
| protocol is supported AS-Interface protocol | Yes |
| product function control circuit interface with IO link | No |
| type of electrical connection of the communication interface | M12 plug |
| type of electrical connection — for main current circuit | plug according to ISO 23570, HAN Q4/2 |
| type of electrical connection — for auxiliary and control circuit | connector |
| type of electrical connection — 1 for digital input signals | M12 socket |
| type of electrical connection — 1 for digital output signals | M12 socket |
| type of electrical connection — 2 for digital input signals | M12 socket |
| type of electrical connection — 3 for digital input signals | M12 socket |
| type of electrical connection — 4 for digital input signals | M12 socket |
| type of electrical connection — at the manufacturer-specific device interface | optical interface |
| type of electrical connection — for device addressing | M12 plug |
| type of electrical connection — for supply voltage line-side | M12 plug |
| full-load current (FLA) for 3-phase AC motor at 480 V rated value | 11 A |
| yielded mechanical performance [hp] — for 3-phase AC motor — at 220/230 V rated value | 3 hp |
| yielded mechanical performance [hp] — for 3-phase AC motor — at 460/480 V rated value | 7.5 hp |
| yielded mechanical performance [hp] — for 3-phase AC motor — at 575/600 V rated value | 10 hp |
| operating voltage at AC at 60 Hz according to CSA and UL rated value | 600 V |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
3RK1315-6LS41-1AA5: frequently asked questions
When can 3RK1315-6LS41-1AA5 be shipped?
3RK1315-6LS41-1AA5 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 3RK1315-6LS41-1AA5 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 3RK1315-6LS41-1AA5 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 3RK1315-6LS41-1AA5, subject to availability and destination.
More Siemens parts