Siemens 3RK1304-0HS00-8AA0

ET 200pro ASM 400 V disconnecting module 400 V to 25 A for safe disconnection up to category 3/4 Han Q4/2

MPN
3RK1304-0HS00-8AA0
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Siemens parts? We buy surplus →

What is the Siemens 3RK1304-0HS00-8AA0?

ET 200pro ASM 400 V disconnecting module 400 V to 25 A for safe disconnection up to category 3/4 Han Q4/2

Specifications

General

product brand nameSIMATIC
product designationMotor starters
design of the productsafety disconnecting module
product type designationET 200pro

General technical data

product function on-site operationNo
insulation voltage rated value400 V
degree of pollution3
surge voltage resistance rated value6 kV
maximum permissible voltage for protective separation between main and auxiliary circuit400 V
degree of protection NEMA ratingType 2, 12
shock resistance15 g / 11 ms
vibration resistance2 g
operating frequency maximum750 1/h
mechanical service life (operating cycles) of the main contacts typical10 000 000
type of coordination1
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)05/28/2009
SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1
Net Weight2.346 kg
product component motor brake outputNo
product feature — brake control with 230 V ACNo
product feature — brake control with 400 V ACNo
product feature — brake control with 24 V DCNo
product feature — brake control with 180 V DCNo
product feature — brake control with 500 V DCNo
product function short circuit protectionNo

Safety related data

safe stateLoad circuit open
stop category according to IEC 60204-10
proportion of dangerous failures — with high demand rate according to SN 3192040 %
failure rate [FIT] at rate of recognizable hazardous failures (λdd)550 FIT
failure rate [FIT] at rate of non-recognizable hazardous failures (λdu)6 FIT
average diagnostic coverage level (DCavg)99 %
MTTFd205 a
PFHD with high demand rate according to IEC 620616E-9 1/h
Safety Integrity Level (SIL) — according to IEC 61508SIL 3
safety device type according to IEC 61508-2Type A
PFDavg with low demand rate according to IEC 615085E-6
Safe failure fraction (SFF)99 %
hardware fault tolerance according to IEC 615081
T1 value for proof test interval or service life according to IEC 6150810 a
touch protection against electrical shockfinger-safe

Main circuit

number of poles for main current circuit3
design of the switching contactelectromechanical
type of voltageAC
operating voltage rated value200 ... 400 V
operating frequency 1 rated value50 Hz
operating frequency 2 rated value60 Hz
relative positive tolerance of the operating frequency10 %
relative negative tolerance of the operating frequency15 %
operating range relative to the operating voltage at AC at 50 Hz200 ... 440 V
operational current — at AC at 400 V rated value25 A
operational current — at AC-3 at 400 V rated value25 A
operational current — at AC-3e at 400 V rated value25 A
operating power — at AC-3 at 400 V rated value11 000 W
operating power — at AC-3e at 400 V rated value11 000 W
operating power for 3-phase motors at 400 V at 50 Hz0 ... 11 000 W

Inputs/ Outputs

product function — digital inputs parameterizableNo
product function — digital outputs parameterizableNo
number of digital inputs0
number of sockets — for digital output signals0
number of sockets — for digital input signals0

Supply voltage

type of voltage of the supply voltageDC
supply voltage 1 at DC24 V
supply voltage 1 at DC rated value — minimum permissible20.4 V
supply voltage 1 at DC rated value — maximum permissible28.8 V

Control circuit/ Control

type of voltage of the control supply voltageDC
control supply voltage at DC rated value20.4 ... 28.8 V
control supply voltage 1 at DC rated value20.4 ... 28.8 V
control supply voltage 1 at DC24 V
control current at DC — in standby mode of operation5 mA
control current at DC — when switching on300 mA
control current at DC — during operation300 mA

Installation/ mounting/ dimensions

mounting positionany
fastening methodscrew fixing
height230 mm
width110 mm
depth157.5 mm

Ambient conditions

installation altitude at height above sea level maximum3 500 m
ambient temperature — during operation-25 ... +55 °C
ambient temperature — during storage-40 ... +70 °C
ambient temperature — during transport-40 ... +70 °C
relative humidity during operation5 ... 95 %

Communication/ Protocol

protocol is supported — PROFIBUS DP protocolYes
protocol is supported — PROFINET protocolYes
protocol is supported — PROFINET IO protocolYes
protocol is supported — PROFIsafe protocolNo
design of the interface PROFINET protocolYes
product function bus communicationYes
protocol is supported AS-Interface protocolNo
product function — supports PROFIenergy measured valuesNo
product function — supports PROFIenergy shutdownNo
address space memory of address range — of the inputs1 byte
address space memory of address range — of the outputs0 byte
type of electrical connection of the communication interfacevia backplane bus

Connections/ Terminals

type of electrical connection — for main current circuittab terminals
type of electrical connection — 1 for digital input signalsM12 socket
type of electrical connection — 2 for digital input signalsM12 socket
type of electrical connection — 3 for digital input signalsM12 socket
type of electrical connection — 4 for digital input signalsM12 socket
type of electrical connection — at the manufacturer-specific device interfaceoptical interface
type of electrical connection — for main energy infeedsocket according to ISO23570
type of electrical connection — for load-side outgoing feedersocket according to ISO23570
type of electrical connection — for main energy transmissionsocket according to ISO23570
type of electrical connection — for supply voltage line-sidevia backplane bus
type of electrical connection — for supply voltage transmissionvia backplane bus

UL/CSA ratings

full-load current (FLA) for 3-phase AC motor at 480 V rated value20 A
yielded mechanical performance [hp] — for 3-phase AC motor — at 200/208 V rated value7.5 hp
yielded mechanical performance [hp] — for 3-phase AC motor — at 220/230 V rated value7.5 hp
yielded mechanical performance [hp] — for 3-phase AC motor — at 460/480 V rated value15 hp
yielded mechanical performance [hp] — for 3-phase AC motor — at 575/600 V rated value20 hp
operating voltage at AC at 60 Hz according to CSA and UL rated value600 V

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

3RK1304-0HS00-8AA0: frequently asked questions

When can 3RK1304-0HS00-8AA0 be shipped?

3RK1304-0HS00-8AA0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 3RK1304-0HS00-8AA0 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 3RK1304-0HS00-8AA0 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 3RK1304-0HS00-8AA0, subject to availability and destination.

More Siemens parts

Siemens 3RK1205-0BQ24-0AA3 – ASIsafe compact module K45F LS Type 4 (light sensor) for testing semiconductor output Sensor supply from AS-i…
Siemens
3RK1205-0BQ24-0AA3

ASIsafe compact module K45F LS Type 4 (light sensor) for…

Siemens 3RK1205-0BQ30-0AA3 – ASIsafe compact module K20F digital safety, 2 F-DI, IP67 2 x input for mechanical sensors 2 x M12 socket
Siemens
3RK1205-0BQ30-0AA3

ASIsafe compact module K20F digital safety, 2 F-DI

Siemens 3RK1205-0CQ00-0AA3 – ASIsafe compact module K45F digital safety, 4 F-DI
Siemens
3RK1205-0CQ00-0AA3

ASIsafe compact module K45F digital safety, 4 F-DI

Siemens 3RK1304-0HS00-6AA0 – ET 200 RSM Maintenance switch module Up to 25 A Up to 25 A Disconnector function for Main circuit Han Q4/2
Siemens
3RK1304-0HS00-6AA0

ET 200 RSM Maintenance switch module Up to 25 A Up to 25 A…

Siemens 3RK1304-5KS40-2AA0 – ET 200pro DSE HF DOL starter High Feature Mechanical switching Electronic overload protection AC-3
Siemens
3RK1304-5KS40-2AA0

ET 200pro DSE HF DOL starter High Feature Mechanical…

Siemens 3RK1304-5KS40-2AA3 – ET 200pro DSE HF DOL starter High Feature Mechanical switching Electronic overload protection AC-3
Siemens
3RK1304-5KS40-2AA3

ET 200pro DSE HF DOL starter High Feature Mechanical…

Siemens 3RK1304-5KS40-3AA0 – ET 200pro RSE HF Reversing starter High Feature Mechanical switching Electronic overload protection AC-3
Siemens
3RK1304-5KS40-3AA0

ET 200pro RSE HF Reversing starter High Feature Mechanical…

Siemens 3RK1304-5KS40-3AA3 – ET 200pro RSE HF Reversing starter High Feature Mechanical switching Electronic overload protection AC-3
Siemens
3RK1304-5KS40-3AA3

ET 200pro RSE HF Reversing starter High Feature Mechanical…

Siemens 3RK1304-0HS00-8AA0Price and lead time confirmed within 1 business day
Request a Quote