Siemens 3RA2325-8XD30-1DW4

Reversing contactor assembly, AC-3e/AC-3, 17 A, 7.5 kW / 400 V, 3-pole, 48 V DC, with plugged-in varistor

MPN
3RA2325-8XD30-1DW4
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Siemens parts? We buy surplus →

What is the Siemens 3RA2325-8XD30-1DW4?

reversing contactor assembly, AC-3e/AC-3, 17 A, 7.5 kW / 400 V, 3-pole, 48 V DC, with plugged-in varistor, screw terminal, electrical and mechanical interlock, 2 x auxiliary switch plugged on, auxiliary contacts: 2 x 3 NO + 2 NC

Specifications

General technical data

size of contactorS0
product extension auxiliary switchYes
shock resistance at rectangular impulse – at AC7,5 g / 5 ms, 4,7 g / 10 ms
shock resistance at rectangular impulse – at DC10g / 5 ms, 7,5g / 10 ms
shock resistance with sine pulse – at AC11,8 g / 5 ms, 7,4 g / 10 ms
shock resistance with sine pulse – at DC15 g / 5 ms, 10 g / 10 ms
mechanical service life (operating cycles) – of contactor typical10 000 000
mechanical service life (operating cycles) – of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)07/01/2006
Net Weight1.311 kg

Ambient conditions

installation altitude at height above sea level maximum2 000 m
ambient temperature – during operation-25 ... +60 °C
ambient temperature – during storage-55 ... +80 °C

Main circuit

number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
operating voltage – at AC-3 rated value maximum690 V
operating voltage – at AC-3e rated value maximum690 V
at AC-3 – — at 400 V rated value17 A
at AC-3 – — at 500 V rated value17 A
at AC-3 – — at 690 V rated value13 A
at AC-3e – — at 400 V rated value17 A
at AC-3e – — at 500 V rated value17 A
at AC-3e – — at 690 V rated value13 A
at AC-3 – — at 400 V rated value7.5 kW
at AC-3 – — at 500 V rated value7.5 kW
at AC-3 – — at 690 V rated value11 kW
at AC-3e – — at 400 V rated value7.5 kW
at AC-3e – — at 690 V rated value11 kW
at AC-3e – at AC-4 at 400 V rated value7.5 kW
operating frequency – at AC-3 maximum1 000 1/h
operating frequency – at AC-3e maximum1 000 1/h

Control circuit/ Control

type of voltage of the control supply voltageDC
control supply voltage 1 at DC rated value48 V
design of the surge suppressorwith varistor
closing power of magnet coil at DC5.9 W
holding power of magnet coil at DC5.9 W

Auxiliary circuit

number of NO contacts for auxiliary contacts – per direction of rotation1
number of NO contacts for auxiliary contacts – instantaneous contact2
contact reliability of auxiliary contacts< 1 error per 100 million operating cycles

UL/CSA ratings

full-load current (FLA) for 3-phase AC motor – at 480 V rated value14 A
full-load current (FLA) for 3-phase AC motor – at 600 V rated value17 A
yielded mechanical performance [hp] for 3-phase AC motor – at 220/230 V rated value5 hp
yielded mechanical performance [hp] for 3-phase AC motor – at 460/480 V rated value10 hp
yielded mechanical performance [hp] for 3-phase AC motor – at 575/600 V rated value15 hp
contact rating of auxiliary contacts according to ULA600 / Q600

Short-circuit protection

for short-circuit protection of the main circuit – — with type of coordination 1 requiredgG NH 3NA, DIAZED 5SB, NEOZED 5SE: 63 A
for short-circuit protection of the main circuit – — with type of coordination 2 requiredgG NH 3NA, DIAZED 5SB, NEOZED 5SE: 25 A
for short-circuit protection of the main circuit – for short-circuit protection of the auxiliary switch requiredfuse gG: 10 A

Installation/ mounting/ dimensions

mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening methodscrew and snap-on mounting onto 35 mm DIN rail
height101 mm
width90 mm
depth107 mm
with side-by-side mounting – — forwards6 mm
with side-by-side mounting – — backwards0 mm
with side-by-side mounting – — upwards6 mm
with side-by-side mounting – — downwards6 mm
with side-by-side mounting – — at the side6 mm
for grounded parts – — forwards6 mm
for grounded parts – — backwards0 mm
for grounded parts – — upwards6 mm
for grounded parts – — at the side6 mm
for grounded parts – — downwards6 mm
for live parts – — forwards6 mm
for live parts – — backwards0 mm
for live parts – — upwards6 mm
for live parts – — downwards6 mm
for live parts – — at the side6 mm

Connections/ Terminals

type of electrical connection – for main current circuitscrew-type terminals
type of electrical connection – for auxiliary and control circuitscrew-type terminals
type of electrical connection – at contactor for auxiliary contactsScrew-type terminals
type of electrical connection – of magnet coilscrew terminal
type of connectable conductor cross-sections for main contacts – solid2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
type of connectable conductor cross-sections for main contacts – solid or stranded2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
type of connectable conductor cross-sections for main contacts – finely stranded with core end processing2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
for auxiliary contacts – — solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for auxiliary contacts – — finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for auxiliary contacts – for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14)

Safety related data

product function suitable for safety functionYes
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front

Communication/ Protocol

product function bus communicationYes
protocol is supported AS-Interface protocolNo
product function control circuit interface with IO linkNo

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

3RA2325-8XD30-1DW4: frequently asked questions

When can 3RA2325-8XD30-1DW4 be shipped?

3RA2325-8XD30-1DW4 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 3RA2325-8XD30-1DW4 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 3RA2325-8XD30-1DW4 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 3RA2325-8XD30-1DW4, subject to availability and destination.

More Siemens parts

Siemens 3RA2325-8XD30-1DW4Price and lead time confirmed within 1 business day
Request a Quote