What is the Sick MAX48N-32V40K80350?

Linear encoders | MAX | MAX48N-32V40K80350 | Type: 48 mm 48f7 for IN cylinder mounting – cylinder bore hole 48H8 | Cable connection direction: Radial | Pipe diameter / Damping zone / End cap: 10 mm / 63 mm / Flat | Supply voltage: 24 V DC (8 ... 32 V DC) | Communication interface: Analog / Voltage | Connection type: Connecting cable, 3-wire, 5,000 mm | Measuring range: 0 mm ... 350 mm | Output signal: 1 V DC ... 9 V DC

Specifications

Features

Items suppliedAccessories not included with delivery, please order separately.

Safety-related parameters

MTTFD (mean time to dangerous failure)69Â years (ENÂ ISOÂ 13849-1)Â 1)

Performance

Type48 mm installation housing – IN cylinder mounting
Pressure pipe/End cap10 mm / Flat
Connection typeConnecting cable, 3-wire, 5,000Â mm
Direction of connectionRadial
Measured valuesPositioning
Position (F.S.)0 mm ... 350 mm 1)
Null zone30 mm
Damping zone63Â mm
Fluid temperature–30 °C ... +95 °C 2)
Air humidity90Â % (Condensation not permitted)
Operating pressure PN400Â bar
Supply voltage24Â VÂ DC (8Â ... 32Â VÂ DC)
Switch-on time<Â 250Â ms
Switch-on currentTyp. 5.0 A / 50 µs
Measuring frequency (internal)2Â ms
Transmission rate (cycle time)Steady
Setpoint tolerance≤ ± 1 mm
Hysteresis± 0,1 mm
RepeatabilityTyp. ± 0.2 mm
LinearityTyp. ± 0.25 mm (measuring range 50 to 500 mm) 3)
Warming up phaseTyp. ≤ ± 0.25 mm (2 min)
In the operational statusTyp. ± 0.25 mm (measuring range 50 to 500 mm) 3)

Interfaces

Communication interfaceAnalog
Communication Interface detailVoltage
Voltage output1Â VÂ DCÂ ... 9Â VÂ DC

Electronics

Connection typeConnecting cable, 3-wire, 5,000Â mm
Supply voltage24Â VÂ DC (8Â ... 32Â VÂ DC)
Residual ripple< 1% S-S
Power consumption≤ 0.75 W
Current consumption≤ 30 mA
Load resistanceRL ≥ 10 kΩ
Overvoltage protection during power-up (60 s)≤ 36 V at all poles during power-up (60 s)≤ 48 V To GND during power-up (60 s)
Reverse polarity protection≤ 36 V (at all poles) (ISO 16750-2)
Insulation resistanceRiso ≥ 10 MΩ, 60 s (ISO 16750-2)
Dielectric strength500 V DC, 0 V DC (60 s) to housing (RISO ≥ 1 MΩ) (ISO 16750-2)
Short-circuit protectionVS – GND on housing

Mechanics

Housing48 mm, 48f7 for IN cylinder mounting – cylinder bore hole 48H8
Ø pressure pipe10 mm
Ø O-ring40.87 mm x 3.53 mm
Ø support ring42.6 mm x 48 mm x 1.4 mm
Ø connecting cableØ 5.0 mm; 3 x 0.38 mm² (AWG22), stripped
Length of cable5,000Â mm
HousingStainless steel 1.4305Â (AISI 303)
Pressure pipeStainless steel 1.4404, AISI 316L
O-ringNBR 70
Support ringPTFE
SheathPUR

Ambient data

EMCEU Directive 2014/30Â /Â EU CE marking
Generic standardsENÂ 61000-6-2/61000-6-3
Agricultural and forestry machineryENÂ ISOÂ 14982
Transient pulsesISOÂ 7637-2/ISOÂ 16750-2
ESD (air and contact discharge)ISOÂ 61000-4-2 / ISOÂ 10605
Sine20 g (sine) / 55 ... 2,000 Hz / 3x24 h (IEC 60068-2-6 Fc)
Sine over noise18 g (r.m.s) / 10 ... 2,000 Hz / 3x36 h (IEC 60068-2-80 Fi)
Broadband noise (resonance peaks removed)20 g (r.m.s) / 10 ... 2,000 Hz / 3x48 h (IEC 60068-2-64 Fh)
Operating pressure PN400Â bar
Overload pressure Pmax = PN x 1.2480 bar
Test pressure Pstat = PN x 1.5600 bar
Storage–20 °C ... +65 °C 1)
Operation (electronics)–40 °C ... +105 °C 2)
Maximum air humidity90Â % (Condensation not permitted)
HousingIP67 (ENÂ 60529)

Classifications

ECLASS 5.027270705
ECLASS 5.1.427270705
ECLASS 6.027270705
ECLASS 6.227270705
ECLASS 7.027270705
ECLASS 8.027270705
ECLASS 8.127270705
ECLASS 9.027270705
ECLASS 10.027270705
ECLASS 11.027270705
ECLASS 12.027274304
ETIM 5.0EC002544
ETIM 6.0EC002544
ETIM 7.0EC002544
ETIM 8.0EC002544
UNSPSC 16.090141111613

MAX48N-32V40K80350: frequently asked questions

When can MAX48N-32V40K80350 be shipped?

MAX48N-32V40K80350 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up MAX48N-32V40K80350 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for MAX48N-32V40K80350 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for MAX48N-32V40K80350, subject to availability and destination.

More Sick parts

Sick MB1-BF11 – Actuators and bolts
Sick
MB1-BF11

Actuators and bolts

Sick MAX48N-32V40K80350Price and lead time confirmed within 1 business day
Request a Quote