What is the Sick DT50-2B215252?

Laser distance sensors | Dx50-2 | DT50-2B215252 | Communication interface: IO-Link | Measuring range: 200 mm ... 30,000 mm, 90% remission factor, 200 mm ... 17,000 mm, 18% reflection factor, 200 mm ... 10,000 mm, 6% remission factor | Laser class: 2 | Light source: Laser, red | Minimum response time: 0.83 ms | Digital output: 1 ... 2 x push-pull: PNP/NPN | Type of analog output: Current output / voltage output | Multifunctional input (MF): 1 x

Specifications

Features

Measuring range200 mm ... 30,000 mm, 90% remission factor 1) 2)200 mm ... 17,000 mm, 18% reflection factor200 mm ... 10,000 mm, 6% remission factor
TargetNatural objects
Resolution100 µm
Repeatability≥ 0.5 mm 2) 3) 4)
Measurement accuracy± 7 mm 4)
Response time0.83 ms ... 75 ms, 0.83 ms / 3.33 ms / 8.33 ms / 25 ms / 75 ms 5) 6)
Switching frequency1,000 Hz/250 Hz/100 Hz/33 Hz/11 Hz 5) 6)
Output time0.33 ms/1.33 ms/3.33 ms/10 ms/30 ms 5) 7)
Light sourceLaser, red 8)
Type of lightVisible red light
Typ. light spot size (distance)10 mm x 10 mm (at 10 m)
Normative referenceIECÂ 60825-1:2014, ENÂ 60825-1:2014
Laser class2
Average laser service life (at 25 °C)100,000 h
Additional functionSet speed: Super Fast ... Super SlowTeach-in, scaling and inversion of analog outputOutput Q2 adaptable: Current output / Voltage output / Digital output / Q1 not / deactivatedSwitching mode: Distance to Object (DtO) / switching window / object between sensor and background (ObSB)Teach-in, scaling and inversion of digital outputMultifunctional input: laser off / external teach / deactivatedReset to factory defaultShape comparison: based on the distance measured over a period of timeHold measurement valueSwitch-off or lock displayEasy teach option
MTTFD101Â years
DCavg0%

Interfaces

IO-Link✔ , IO-Link V1.1, COM3 (230,4 kBaud)
FunctionProcess data, parameterization, diagnosis, data storage
Number1Â ... 2Â 1)Â 2)Â 3)
TypePush-pull: PNP/NPN
FunctionComplementary digital outputs (Q, Ǭ)
Maximum output current IA≤ 100 mA
Number1
TypeCurrent output / voltage output
FunctionOutput Q2 adaptable: Current output / Voltage output / Digital output / Q1 not / deactivated
Current4 mA ... 20 mA, ≤ 450 Ω
Voltage0 V ... 10 V, ≥ 50,000 Ω
Resolution16Â bit
Multifunctional input (MF)1 x 4)
Hysteresis0 mm ... 29,950 mm

Electronics

Supply voltage UBDC 10Â VÂ ... 30Â VÂ 1)Â 2)
Power consumption≤ 1.7 W 3)
Ripple≤ 5 Vpp 4)
Initialization time≤ 300 ms
Warm-up time≤ 15 min
Display3Â x LED, LC display
Enclosure ratingIP65IP67
Protection classIII

Mechanics

Dimensions (W x H x D)36.2 mm x 63 mm x 58.6 mm
Housing materialMetal (zinc diecast)
Window materialPlastic (PMMA)
Weight235Â g

Ambient data

Ambient temperature, operation–40 °C ... +65 °C, Uv ≤ 24 V–30 °C ... +140 °C, operation with 2 cooling plates (2055755) / optionally with heat protection filter (2085598) 1)
Ambient temperature, storage–40 °C ... +75 °C
Max. rel. humidity (not condensing)≤ 95 %
Typ. Ambient light immunity40,000Â lx
Vibration resistance(IEC 60068-2-64:2008) Noise test: 20 Hz ... 500 Hz, 10 g RMS, 2 h / axis
Shock resistance(IEC 60068-2-27:2008) 30 g, 11 ms, 3 axes, ± 3 single shocks / axis(IEC 60068-2-27:2008) 10 g, 6 ms, 3 axes, ± 500 shocks / axis(IEC 60068-2-27:2008) 70 g, 6 ms, Y-axis, ± 100,000 shocks
Electromagnetic compatibility (EMC)ENÂ 61000-6-2, ENÂ 61000-6-4Â 2)

Certificates

EU declaration of conformity✔
UK declaration of conformity✔
ACMA declaration of conformity✔
Moroccan declaration of conformity✔
China RoHS✔
cULus certificate✔
IO-Link certificate✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)✔

Classifications

ECLASS 5.027270801
ECLASS 5.1.427270801
ECLASS 6.027270801
ECLASS 6.227270801
ECLASS 7.027270801
ECLASS 8.027270801
ECLASS 8.127270801
ECLASS 9.027270801
ECLASS 10.027270801
ECLASS 11.027270801
ECLASS 12.027270916
ETIM 5.0EC001825
ETIM 6.0EC001825
ETIM 7.0EC001825
ETIM 8.0EC001825
UNSPSC 16.090141111613

DT50-2B215252: frequently asked questions

When can DT50-2B215252 be shipped?

DT50-2B215252 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up DT50-2B215252 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for DT50-2B215252 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for DT50-2B215252, subject to availability and destination.

More Sick parts

Sick DT50-N1124 – Laser distance sensors
Sick
DT50-N1124

Laser distance sensors

Sick DT50-N2123 – Laser distance sensors
Sick
DT50-N2123

Laser distance sensors

Sick DT50-P1113 – Laser distance sensors
Sick
DT50-P1113

Laser distance sensors

Sick DT50-P1114 – Laser distance sensors
Sick
DT50-P1114

Laser distance sensors

Sick DT50-2B215252Price and lead time confirmed within 1 business day
Request a Quote