Schneider Electric VCCDN12

Switch disconnector,TeSys Control,for ON/emergency stop,12A(VN12),for mounting at back of an enclosure

MPN
VCCDN12
EAN
3389110759938
Category
TeSys Vario
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

What happens next
  1. We check stock, condition and lead time
  2. You get a written quote by email
  3. Approve it and we ship — in-stock parts within 1 business day
  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via
  • 100% positive eBay feedback

Have spare Schneider Electric parts? We buy surplus →

What is the Schneider Electric VCCDN12?

TeSys Vario switch disconnector for mounting at back of an enclosure, 3 poles, 12A/690V, for motor switching applications up to 4kW@400V AC-23. Complete unit composed of a switch body V0, an extension shaft VZN17, a door interlock plate KZ32, a red handle with yellow 60x60mm front plate KCD1PZ. Intended for main and emergency stop switch disconnecting usage. Padlockable handle, for 3 padlocks (to be ordered separately). Handle with central fixing on door, ensuring IP65 to the mounting. Possible distance between back of enclosure and door 300-330mm. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).

Specifications

Specifications

RangeTeSys
Product nameTeSys Mini-VARIO
Device short nameVCCDN
Product or component typeEmergency stop switch disconnector
Performance levelStandard
Poles description3P
Contacts type and composition3 NO
Network typeAC, DC
Control typeRotary handle
Rotary handle mounting styleExtended
Handle colourRed
Handle front plate colourYellow
Rotary handle padlocking1 to 3 padlocks 4…8 mm
Marking0 - 1
Mounting supportHandle: door, Switch: symmetrical rail
Fixing modeHole with 22.5 mm for handle, By clips for switch
[Ue] rated operational voltage690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
[Ith] conventional free air thermal current12 A
[Ithe] conventional enclosed thermal current10 A
[Ie] rated operational current8.1 A (AC-23) at 400 V
Rated operational power in W3 kW at 230...240 V (AC-23A), 4 kW at 400...415 V (AC-23A), 5.5 kW at 500 V (AC-23A), 7.5 kW at 690 V (AC-23A), 1.5 kW at 230...240 V (AC-3), 3 kW at 400...415 V (AC-3), 4 kW at 500 V (AC-3), 4 kW at 690 V (AC-3)
Intermittent duty class30
Making capacity ( I Rms)120 A at 400 V AC-21A, 120 A at 400 V AC-22A, 120 A at 400 V AC-23A
[Icm] rated short-circuit making capacity0.5 kA at 400 V at Ipeak
[Icw] rated short-time withstand Rms current140 A at 400 V duration: 1 s
Rated conditional short-circuit current6 kA at 400 V - associated fuse 12 A aM, 6 kA at 400 V - associated fuse 12 A gG
Breaking capacity120 kA at 400 V (AC-21A), 120 kA at 400 V (AC-22A), 120 kA at 400 V (AC-23A)
Device compositionSwitch, Handle, Shaft extension
Mechanical durability50000 cycles
Electrical durability30000 cycles DC-1...5, 50000 cycles AC-21
Suitability for isolationYes
Connections - terminalsPower circuit: screw clamp terminals4 mm² - flexible - with cable end, Power circuit: screw clamp terminals4 mm² - solid
Tightening torquePower circuit: 0.7 N.m - on screw clamp terminals
handle front plate dimension60 x 60 mm
Height60 mm
Width60 mm
Net weight0.334 kg
StandardsIEC 60947-3
Product certificationsGL, CCC, UL, CSA, UKCA
Protective treatmentTC
IP degree of protectionIP65
Mechanical robustnessVibrations 10...150 Hz (5 gn) conforming to IEC 60068-2-6, Shocks 11 ms (15 gn) conforming to IEC 60068-2-27
Ambient air temperature for operation-20…50 °C
Fire resistance960 °C conforming to IEC 60695-2-1

Packaging

Package 11 PCE, 25.5 cm × 8.8 cm × 7.5 cm (L × W × H), 314.0 g
Package 212 S03, 40.0 cm × 30.0 cm × 30.0 cm (L × W × H), 4.282 kg

Downloads & documentation

Official documents from Schneider Electric, downloaded directly from the manufacturer.

Data sheets & manuals

VCCDN12: frequently asked questions

When can VCCDN12 be shipped?

VCCDN12 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up VCCDN12 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for VCCDN12 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VCCDN12, subject to availability and destination.

More Schneider Electric parts

Schneider Electric VCCD0 – Switch-disconnectors,TeSys Control,for ON/emergency stop,25A,fixing by single hole Ø22.5mm,for mounting at back of an enclosure
Schneider Electric
VCCD0

Switch-disconnectors,TeSys Control,for ON/emergency stop,25A,fixing by single hole Ø22.5mm,for mounting at back of an enclosure

Schneider Electric VCCD01 – Switch-disconnectors,TeSys Control,for ON/emergency stop,20A(V01),fixing by single hole Ø22.5mm,for mounting at back of an enclosure
Schneider Electric
VCCD01

Switch-disconnectors,TeSys Control,for ON/emergency stop,20A(V01),fixing by single hole Ø22.5mm,for mounting at back of an enclosure

Schneider Electric VCCD02 – Switch-disconnectors,TeSys Control,for ON/emergency stop,12A(V02),fixing by single hole Ø22.5mm,for mounting at back of an enclosure
Schneider Electric
VCCD02

Switch-disconnectors,TeSys Control,for ON/emergency stop,12A(V02),fixing by single hole Ø22.5mm,for mounting at back of an enclosure

Schneider Electric VCCD2 – Switch-disconnectors,TeSys Control,for ON/emergency stop,40A,fixing by single hole Ø22.5mm,for mounting at back of an enclosure
Schneider Electric
VCCD2

Switch-disconnectors,TeSys Control,for ON/emergency stop,40A,fixing by single hole Ø22.5mm,for mounting at back of an enclosure

Schneider Electric VCCDN20 – Switch disconnector,TeSys Control,for ON/emergency stop,20A(VN20),for mounting at back of an enclosure
Schneider Electric
VCCDN20

Switch disconnector,TeSys Control,for ON/emergency stop,20A(VN20),for mounting at back of an enclosure

Schneider Electric VCCF0 – Switch disconnector,TeSys Control,for ON/emergency stop,25A,4 screws fixing,for mounting at back of an enclosure
Schneider Electric
VCCF0

Switch disconnector,TeSys Control,for ON/emergency stop,25A,4 screws fixing,for mounting at back of an enclosure

Schneider Electric VCCF01 – Switch disconnector,TeSys Control,for ON/emergency stop,20A(V01),4 screws fixing,for mounting at back of an enclosure
Schneider Electric
VCCF01

Switch disconnector,TeSys Control,for ON/emergency stop,20A(V01),4 screws fixing,for mounting at back of an enclosure

Schneider Electric VCCF02 – Switch disconnector,TeSys Control,for ON/emergency stop,12A(V02),4 screws fixing,for mounting at back of an enclosure
Schneider Electric
VCCF02

Switch disconnector,TeSys Control,for ON/emergency stop,12A(V02),4 screws fixing,for mounting at back of an enclosure

Schneider Electric VCCDN12Price and lead time confirmed within 1 business day
Request a Quote