Schneider Electric TWDLCAA24DRF – Compact base controller, Twido, 100 to 240VAC supply, extendable PLC base, 14 inputs with 24VDC, 10 output relays
Discontinued by Schneider Electric — we can still source the original TWDLCAA24DRF (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Twido |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Country of origin | FR |
| UPC / EAN | 3595862044226 |
| Recommended replacement | TM221C24R, TM241C24R, TM3DM8R |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
Can I still buy the TWDLCAA24DRF now that it is discontinued?
Yes. Schneider Electric has discontinued the TWDLCAA24DRF, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time. If you are planning an upgrade instead, Schneider Electric names the TM221C24R as its successor — we can quote both.
When can TWDLCAA24DRF be shipped?
TWDLCAA24DRF is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up TWDLCAA24DRF in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for TWDLCAA24DRF and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for TWDLCAA24DRF, subject to availability and destination.
Schneider Electric TWDLCAA24DRF — Compact base controller, Twido, 100 to 240VAC supply, extendable PLC base, 14 inputs with 24VDC, 10 output relays. Discontinued by Schneider Electric; the manufacturer's successor is TM221C24R. PartnerPLC sources discontinued and surplus Schneider Electric automation parts — request a quote for price, condition and lead time.
Specifications
Main
| Range of product | Twido |
| Product or component type | Compact base controller |
| Discrete I/O number | 24 |
| Discrete input number | 14 |
| Discrete input voltage | 24 V |
| Discrete input voltage type | DC |
| Discrete output number | 10 for relay |
| [Us] rated supply voltage | 100...240 V AC |
| Maximum number of I/O expansion module | 4 |
| Use of slot | Memory cartridge or realtime clock cartridge |
| Data backed up | Internal RAM lithium, 30 days autonomy, charging time: 10 h, battery life: 10 year(s) |
| Integrated connection type | Power supply; Non isolated serial link mini DIN, Modbus/character mode master/slave RTU/ASCII (RS485) half duplex, 38.4 kbit/s; Serial link interface adaptor (RS232C/RS485) |
| Complementary function | Event processing; PID |
| Range compatibility | Twido |
Complementary
| Discrete input logic | Sink or source |
| Input voltage limits | 20.4...28.8 V |
| Discrete input current | 11 mA for I0.0 to I0.1; 7 mA for I0.2 to I0.13 |
| Input impedance | 2100 Ohm for I0.0 to I0.1; 3400 Ohm for I0.2 to I0.13 |
| Filter time | 150 µs + programmed filter time for I0.6 to I0.13 at state 0; 35 µs + programmed filter time for I0.0 to I0.5 at state 1; 40 µs + programmed filter time for I0.6 to I0.13 at state 1; 45 µs + programmed filter time for I0.0 to I0.5 at state 0 |
| Insulation between channel and internal logic | 1500 Vrms for 1 minute |
| Insulation resistance between channel | None |
| Minimum load | 0.1 mA |
| Contact resistance | 30000 µOhm |
| Load current | 2 A at 240 V AC inductive load, operating rate <30 cyc/mn for relay output; 2 A at 240 V AC resistive load, operating rate <30 cyc/mn for relay output; 2 A at 30 V DC inductive load, operating rate <30 cyc/mn for relay output; 2 A at 30 V DC resistive load, operating rate <30 cyc/mn for relay output |
| Mechanical durability | 20000000 cycles for relay output |
| Electrical durability | 100000 cycles for relay output |
| Current consumption | 36 mA at 5 V DC at state 1; 5 mA at 5 V DC at state 0; 55 mA at 24 V DC at state 1 |
| I/O connection | Non-removable screw terminal block |
| Maximum input/output number | 120 spring terminal block with I/O expansion module; 152 HE-10 connector with I/O expansion module; 88 removable screw terminal block with I/O expansion module |
| Network frequency | 50/60 Hz |
| Supply voltage limits | 85…264 V |
| Network frequency limits | 47…63 Hz |
| Power supply output current | 0.25 A for 24 V DC sensors |
| Input current | 450 mA |
| Inrush current | 40 A |
| Protection type | Power protection by internal fuse |
| Power consumption in VA | 33 VA at 100 V; 40 VA at 264 V |
| Insulation resistance | > 10 MOhm at 500 V, between I/O and earth terminals; > 10 MOhm at 500 V, between supply and earth terminals |
| Program memory | 3000 instructions |
| Exact time for 1 Kinstruction | 1 ms |
| System overhead | 0.5 ms |
| Memory description | Internal RAM, 128 counters, no floating, no trigonometrical; Internal RAM, 128 timers, no floating, no trigonometrical; Internal RAM, 256 internal bits, no floating, no trigonometrical; Internal RAM, 3000 internal words, no floating, no trigonometrical; Internal RAM, double words, no floating, no trigonometrical |
| Free slots | 1 |
| Realtime clock | Without clock |
| Counting input number | 1 counting input(s) at 20000 Hz 32 bits; 3 counting input(s) at 5000 Hz 16 bits |
| Analogue adjustment points | 1 point adjustable from 0 to 511 points; 1 point adjustable from 0...1023 |
| Status LED | 1 LED (green) PWR; 1 LED (green) RUN; 1 LED per channel (green) I/O status; 1 LED (red) module error (ERR); 1 LED user pilot light (STAT) |
| Depth | 70 mm |
| Height | 95 mm |
| Width | 90 mm |
| Terminals description PLC n°1 | (6)IN_DIS#6; COM_NEG#0-13; (-)PW_OUT_NEG; (4)IN_DIS#4; ALT; (0)IN_DIS#0; (13)IN_DIS#13; (5)IN_DIS#5; (8)IN_DIS#8; (10)IN_DIS#10; (11)IN_DIS#11; TB_TOP; (+)PW_OUT_POS; (9)IN_DIS#9; (3)IN_DIS#3; (7)IN_DIS#7; (12)IN_DIS#12; (1)IN_DIS#1; (2)IN_DIS#2 |
| Terminals description PLC n°2 | (11)IN_DIS#10; (9)IN_DIS#9; (2)IN_DIS#2; (1)IN_DIS#1; (7)IN_DIS#7; (3)IN_DIS#3; (8)IN_DIS#8; (+)PW_OUT_POS; ALT_1; COM_POS#0-13; (12)IN_DIS#12; (-)PW_OUT_NEG; (4)IN_DIS#4; (13)IN_DIS#13; TB_TOP; (6)IN_DIS#6; (10)IN_DIS#10; (0)IN_DIS#0; (5)IN_DIS#5 |
| Terminals description PLC n°3 | (COM0)COM#0-3; (9)OUT_DIS#9; (7)OUT_DIS#7; (3)OUT_DIS#3; (1)OUT_DIS#1; (GND)GROUND; (6)OUT_DIS#6; (-)PW_NEG; (COM2)COM#8; TB_BOTTOM; (COM1)COM#4-7; (8)OUT_DIS#8; (COM3)COM#9; (5)OUT_DIS#5; (4)OUT_DIS#4; (2)OUT_DIS#2; (0)OUT_DIS#0; (+)PW_POS |
| Net weight | 0.305 kg |
Environment
| Immunity to microbreaks | 10 ms |
| Dielectric strength | 1500 V for 1 minute, between I/O and earth terminals; 1500 V for 1 minute, between supply and earth terminals |
| Product certifications | UL; CSA |
| Marking | CE |
| Ambient air temperature for operation | 0…55 °C |
| Ambient air temperature for storage | -25…70 °C |
| Relative humidity | 30…95 % without condensation |
| IP degree of protection | IP20 |
| Operating altitude | 0...2000 m |
| Storage altitude | 0…3000 m |
| Vibration resistance | 0.075 mm at 10…57 Hz on 35 mm symmetrical DIN rail; 1 gn at 57…150 Hz on 35 mm symmetrical DIN rail; 1.6 mm at 2…25 Hz on plate or panel with fixing kit; 4 gn at 25…100 Hz on plate or panel with fixing kit |
| Shock resistance | 15 gn for 11 ms |
Downloads & documentation
Official documents from Schneider Electric, downloaded directly from the manufacturer.
Data sheets & manuals
| Product data sheet TWDLCAA24DRF |
More Schneider Electric parts
Available on requestscrew terminal block -13 contacts - for modular base controller - Twido
Available on requestscrew terminal block -16 contacts - for modular base controller - Twido
Available on requestCompact base controller, Twido, 100 to 240VAC supply, extendable, 6 inputs with 24VDC, 4 output relays
Available on requestCompact base controller, Twido, 100 to 240VAC supply, extendable, 9 inputs with 24VDC, 7 output relays
Available on requestCompact base controller, Twido, 100 to 240VAC supply, compact, 14 inputs with 24VDC, 10 output relays
Available on requestcompact PLC base Twido - 100..240 V AC supply - 24 I 24 V DC - 16 O
Available on requestCompact base controller, Twido, 24VDC supply, compact, 6 inputs with 24VDC, 4 output relays
Available on requestCompact base controller, Twido, 24VDC supply, compact, 9 inputs with 24VDC, 7 output relays