What is the Schneider Electric TM5SDM8TBFS?
This product is part of the Modicon TM5 range, an High-Performance and Safe IP20 Modular I/O System. This Safety discrete IO module provides 6 inputs, 24V DC, sink and 2 outputs, 24V DC, 500mA. There is an isolation between channel and bus at 500V AC. This safety module, associated with TM5CSLC safety logic controller provides distributed safety solutions on Sercos bus up to SIL 3, Cat. 4, PL e, SIL CL3. It features 2 LEDs for power supply, 2 LEDs for safety status and 20 LEDs for input status signaling. It is furnished with 2 wires for electrical connection. Its housing colour is red. It weighs 0.066kg. It measure 75mm deep, 25mm wide, 99mm high. The Modicon TM5 meets the typical requirements of production and packaging machinery, as well as material handling and assembly systems. This product is certified by GOST-R, C-Tick, cULus and CSA. It meets IEC 61131-2, UL 508, CSA C22.2 No 213 and CSA C22.2 No 142 standards. It is compatible with Modicon TM5CSLC safety logic controller. It is installed by mounting on a 35mm DIN rail. This modular IO system provides a flexible and scalable configuration of remote or distributed IO islands by connection with Modicon and PacDrive 3 controllers. Flexible and scalable, designed for complex machines.
Specifications
Specifications
| Range of product | Modicon TM5 |
| Product or component type | Safety discrete I/O module |
| Product compatibility | PacDrive LMC Eco, PacDrive LMC Pro 2, PacDrive LMC Pro |
| Range compatibility | PacDrive LMC motion controller |
| Discrete input number | 6 at 24 V DC |
| Discrete input voltage | 24 V DC (voltage limits: 20.4...28.8 V) |
| Discrete input logic | Sink |
| Discrete output number | 2 transistor at 24 V DC |
| Discrete output logic | Source |
| Discrete output voltage | 24 V DC (20.4...28.8 V) for transistor |
| Discrete input current | 2.48 mA at 24 V DC |
| Voltage state 1 guaranteed | >= 15 V |
| Voltage state 0 guaranteed | <= 5 V |
| Input impedance | 9.68 kOhm |
| Input filtering | <= 500 ms configurable by software, <= 150 ms hardware |
| Safety level | SIL 3 conforming to IEC 61508, SIL 3 conforming to IEC 62061, PL = e conforming to EN 13849-1 |
| Safety reliability data | PFD < 1E-5, PFH < 1E-9, MTTFd = 2500 years |
| Electrical connection | 2 wires |
| Local signalling | 1 LED (green) for power supply, 1 LED (red) for power supply, 2 LEDs (red) for safety status, 2 LEDs (red/orange) for output status, 6 LEDs (green/red) for input status |
| Height | 99 mm |
| Width | 25 mm |
| Depth | 75 mm |
| Net weight | 0.066 kg |
| Electromagnetic compatibility | Electrostatic discharge immunity test, 4 kV on contact conforming to IEC 61000-4-2, Electrostatic discharge immunity test, 8 kV in air conforming to IEC 61000-4-2, Susceptibility to electromagnetic fields, 10 V/m 80...2000 MHz conforming to IEC 61000-4-3, Electrical fast transient/burst immunity test, 1 kV I/O conforming to IEC 61000-4-4, Electrical fast transient/burst immunity test, 1 kV shielded cable conforming to IEC 61000-4-4, Electrical fast transient/burst immunity test, 2 kV power lines conforming to IEC 61000-4-4, 1.2/50 µs shock waves immunity test, 0.5 kV differential mode conforming to IEC 61000-4-5, 1.2/50 µs shock waves immunity test, 1 kV common mode conforming to IEC 61000-4-5, Conducted RF disturbances conforming to IEC 61000-4-6, Conducted and radiated emissions conforming to CISPR 11 |
| IP degree of protection | IP20 |
| Marking | CE |
| Product certifications | CSA, CULus |
| Standards | CSA C22.2 No 142, EN 13849-1, IEC 61508, IEC 62061, IEC 61131-2 |
| Ambient air temperature for operation | 0…50 °C (vertical installation), 0…55 °C (horizontal installation) |
| Ambient air temperature for storage | -40…70 °C |
| Relative humidity | 5…95 % without condensation |
| Operating altitude | 0...2000 m |
| Pollution degree | 2 |
| Vibration resistance | 1 gn (f = 8.4…150 Hz) on DIN rail, 3.5 mm (f = 5…8.4 Hz) on DIN rail |
| Shock resistance | 15 gn for 11 ms |
Packaging
| Package 1 | 1 PCE, 10.000 cm × 6.000 cm × 3.000 cm (L × W × H), 67.000 g |
| Package 2 | 50 S02, 40.000 cm × 30.000 cm × 15.000 cm (L × W × H), 3.845 kg |
No matching specifications
Downloads & documentation
Official documents from Schneider Electric, downloaded directly from the manufacturer.
Data sheets & manuals
TM5SDM8TBFS: frequently asked questions
When can TM5SDM8TBFS be shipped?
TM5SDM8TBFS is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up TM5SDM8TBFS in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for TM5SDM8TBFS and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for TM5SDM8TBFS, subject to availability and destination.
More Schneider Electric parts



Safety discrete I/O module, Modicon TM5, digital 2I, 2O, 24V DC, 6 A, relay n/o

Discrete I/O module, Modicon TM5, Digital input/output 4DI/4DO 24 V dcTime stamp 1 wire


Discrete output module kit, Modicon TM5, TM5SDO12T with term. block TM5ACTB12 with bus base TM5ACBM11


Discrete output module, Modicon TM5, relay 2O, 24V DC/230 V AC, 6 A, relay, 2 NO