Current transformer tropicalised DIN mount 800 5 cables d. 40 - bars 12x50 20x40
Power quality meter, PowerLogic PM8000, Essential, integrated display, 64 MB, 128 s/c
"The PowerLogic PM8110 comes in a flush mount form factor with integrated display and LVDC control power." "It is designed to help you ensure reliability and efficiency of your power-critical facilitiy." "With its modular, flexible, and power ION technology, you can build custom applications for each meter." "It comes with revenue grade accuracy, multiple communication ports, and a color graphical display." "Certified by third party labs for Class 0.2S energy accuracy (IEC62052-11, IEC62053-24, IEC62053-22)." "Cybersecurity features include secure protocols (HTTPs, sFTP, Secure ION), security event logging, Syslog protocol." "Ability to enable/disable communication ports and support 50 configurable user account to help manage access." "With 64MB of memory to support up to 10 data logs (160 channels), 50+ user-definable alarms, waveform captures upto 128 samples/cycle, 1/2 cycle RMS logging." "The storage can also be used for custom web pages, min/max logs, energy trends, and Time of Use." "The ability to timestamp events to +/-1ms utilizing time synchronization." "Time synch method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function." "3 digital inputs and one digital output, plus the ability to add up to 4 option modules." "I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs" "Wide control power range of 20-60 VDC." "Operating environment of -25 to +70°C; Humidity rating of 5% to 95%; Altitude up to 3000 m."
| Range | PowerLogic |
| Product name | PowerLogic PM8000 |
| Product or component type | Power meter |
| Device short name | PM8110 |
| Market segment | Buildings large building cost management: billing: sub feeder, Buildings small building network management: main incomer, Buildings medium building network management: main incomer, Buildings large building network management: main incomer, Buildings large building network management: sub feeder, Buildings multi-site network management: main incomer, Buildings multi-site network management: sub feeder, Data center network management: main incomer, Data center network management: sub feeder, Healthcare network management: main incomer, Healthcare large building network management: billing: sub feeder, Industry multi-site network management: main incomer, Industry network management: sub feeder, Utility network management: sub feeder |
| model type | Essential |
| Power quality analysis | Conforming to EN 50160: 2010 compliance report, conforming to IEEE 519: 2014 compliance report, up to the 63rd harmonic, harmonic distortion, waveform capture, voltage sag and swell detection, programmablity (logic and math functions), conforming to IEC 62586 power quality monitoring |
| Device application | Power monitoring, WAGES metering |
| Type of measurement | Current total, Voltage, Frequency, Active and reactive power total, Apparent power total, Power factor total, Active and reactive power per phase, rms, Apparent power per phase, rms, Power factor per phase, rms |
| supply voltage | 20...60 V DC +/- 10 % |
| Network frequency | 60 Hz, 50 Hz |
| [In] rated current | 10 A, 5 A, 1 A |
| Poles description | 3P, 1P + N, 3P + N |
| Power consumption in W | 18 W |
| Display type | Colour TFT LCD |
| Display resolution | 320 x 240 pixels QVGA |
| Sampling rate | 128 samples/cycle |
| Measurement current | 50…10000 mA |
| Analogue input type | Voltage (impedance 5 MOhm), Current (impedance 0.3 mOhm) |
| Measurement voltage | 57…400 V AC 42...69 Hz between phase and neutral, 100…690 V AC 42...69 Hz between phases |
| Frequency measurement range | 42…69 Hz |
| Number of inputs | 3 digital 30 V AC, 3 digital 60 V DC |
| Measurement accuracy | Current +/- 0.1 %, Voltage +/- 0.1 %, Active energy +/- 0.2 % |
| Accuracy class | Class 0.2S active energy conforming to IEC 62053-22, Class 0.2 active energy conforming to ANSI C12.20, Class 0.2 active power conforming to IEC 61557-12, Class 0.5S reactive energy conforming to IEC 62053-24, Class 0.5 power factor conforming to IEC 61557-12, Class 0.2 voltage conforming to IEC 61557-12, Class 0.2 current conforming to IEC 61557-12 |
| Number of outputs | 1 pulse |
| Information displayed | Voltage, Current, Frequency, Power, Energy consumption, Harmonic distortion |
| Communication port protocol | Modbus RTU at 115 kbauds - 2-wire, ION at 115 kbauds - 2-wire, DNP3, IEC 61850, Modbus TCP/IP, Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s, RSTP 801.1d 2004 |
| Communication port support | ETHERNET, Screw terminal block: RS485 |
| Communication network type | IPv6 (internet protocol) |
| Data recording | Data logs, Harmonics logs, Waveform logs, Min/max of instantaneous values, Trending/forecasting, Sag and swell logs, Sequence of event recording, GPS synchronisation, Alarm logs, Event logs, Time stamping, 10 data recorders |
| Memory capacity | 64 MB |
| Web services | Customizable home page, File upload/download via FTP, File upload/download via SFTP, Web server, Alarm notification by e-mail, Viewing of captured waveform (FTP), Viewing of captured waveform (web), HTTPS server |
| Communication service | NTP time synchronization, SMTP e-mail notification, DHCP, RSTP support, SNMP, PTP time synchronization |
| Cybersecurity | Syslog protocol support, Password protection, Port hardening, Enable/disable communication ports, Robust security logs |
| Mounting mode | Flush-mounted |
| Mounting support | Framework |
| Installation category | III |
| Safety Construction | III400…690 V conforming to IEC 61010-1:ed. 3, III400…690 V conforming to EN 61010-1:ed. 3, III347…600 V conforming to UL 61010-1:ed. 3, III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3 |
| Standards | IEC 62052-11, IEC 61557-12, IEC 62053-22, IEC 62053-24, IEEE 1588, IEC 62586-2, IEC 61326-1 |
| Product certifications | CE, CULus, N998 |
| Width | 96 mm |
| Depth | 77.5 mm |
| Height | 96 mm |
| Net weight | 581 g |
| Electromagnetic compatibility | Electrostatic discharge conforming to IEC 61000-4-2, Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3, Electrical fast transient/burst immunity test conforming to IEC 61000-4-4, Surge immunity test conforming to IEC 61000-4-5, Conducted RF disturbances conforming to IEC 61000-4-6, Magnetic field at power frequency (2...150 Hz) conforming to IEC 61000-4-8, Voltage dips and interruptions immunity test conforming to IEC 61000-4-11, Immunity to impulse waves conforming to IEC 61000-4-12, Conducted and radiated emissions conforming to EN 55022, Conducted and radiated emissions conforming to EN 55011, Conducted and radiated emissions conforming to FCC part 15, Conducted and radiated emissions conforming to ICES-003, Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579, Surge withstand conforming to IEEE C37.90.1 |
| IP degree of protection | IP54 front: conforming to IEC 60529, IP30 body: conforming to IEC 60529 |
| Relative humidity | 5…95 % |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Operating altitude | 3000 m |
| Package 1 | 1 PCE, 19.000 cm × 13.500 cm × 14.000 cm (L × W × H), 814.000 g |
Official documents from Schneider Electric, downloaded directly from the manufacturer.
METSEPM8110 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Yes — mention it when you request a quote for METSEPM8110 and we'll include express shipping options in our reply.
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for METSEPM8110, subject to availability and destination.

Current transformer tropicalised DIN mount 800 5 cables d. 40 - bars 12x50 20x40



PowerLogic series terminal covers and sealing instructions for PM8000

Power quality meter, PowerLogic PM8000, Essential, transducer, 64 MB, 128 s/c

Power quality meter, PowerLogic PM8000, Essential, transducer and remote display, 64 MB, 128 s/c

Power quality meter, PowerLogic PM8000, Essential, integrated display, 64 MB, 128 s/c

Power quality meter, PowerLogic PM8000, Essential, integrated display, 64 MB, 128 s/c, MID certified