Schneider Electric LXM05AD17M2 – motion servo drive LXM05A - 1.2 kW - 200..240 V - 1-phase - with EMC filter
Discontinued by Schneider Electric — we can still source the original LXM05AD17M2 (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Lexium 05 |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| UPC / EAN | 3389119206990 |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
Can I still buy the LXM05AD17M2 now that it is discontinued?
Yes. Schneider Electric has discontinued the LXM05AD17M2, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can LXM05AD17M2 be shipped?
LXM05AD17M2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LXM05AD17M2 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LXM05AD17M2 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LXM05AD17M2, subject to availability and destination.
Schneider Electric LXM05AD17M2 — motion servo drive LXM05A - 1.2 kW - 200..240 V - 1-phase - with EMC filter (Lexium 05). Discontinued by Schneider Electric. PartnerPLC sources discontinued and surplus Schneider Electric automation parts — request a quote for price, condition and lead time.
Specifications
Main
| Range of product | Lexium 05 |
| Product or component type | Motion servo drive |
| Component name | LXM05A |
| Network number of phases | Single phase |
| power supply voltage | 200...240 V - 15...10 % |
| Continuous output current | 7 A at 8 kHz; 8 A at 4 kHz |
| Nominal power | 1.2 kW at 4 kHz |
| Discrete input number | 2 safety discrete input(s); 4 logic discrete input(s) |
| Analogue input number | 2 |
| Type of polarization | Integrated and switchable impedances for CANopen; No polarization impedances for Modbus |
Complementary
| power supply voltage limits | 170…264 V |
| Supply frequency | 50/60 Hz - 5...5 % |
| power supply frequency limits | 47.5…63 Hz |
| transient RMS output current | 11 A at 8 kHz for 3 s; 12 A at 4 kHz for 3 s |
| Line current | 10.5 A at 240 V; 12.7 A at 200 V |
| maximum prospective line Isc | 1 kA |
| Switching frequency | 8 kHz; 4 kHz |
| Overvoltage category | III |
| Inrush current | 60 A |
| Maximum leakage current | 30 mA |
| Output voltage | <= power supply voltage |
| Insulation | Electrical between power and control |
| recommended type of cable for mounting in an enclosure | Single-strand IEC cable (temperature: 45 °C) copper 70 °C PVC; Single-strand IEC cable (temperature: 45 °C) copper 90 °C XLPE/EPR |
| Electrical connection | Terminal, clamping capacity: 6 mm², 10 AWG (PA/+, PBI, PBe); Terminal, clamping capacity: 6 mm², 10 AWG (R/L1, S/L2, T/L3) |
| Tightening torque | PA/+, PBI, PBe: 1.2 N.m; R/L1, S/L2, T/L3: 1.2 N.m |
| Discrete input type | Logic (LI1, LI2, LI3, LI4 terminals); Safety (PWRR_A, PWRR_B terminals) |
| Sampling duration | ANA1+/ANA1-, ANA2+/ANA2-: 0.25 ms analog; LI1, LI2, LI3, LI4: 0.25 ms discrete |
| Discrete input voltage | 24 V DC for logic; 24 V DC for safety |
| Discrete input logic | Negative (LI1, LI2, LI3, LI4) at State 0: > 19 V at State 1: < 9 V conforming to EN/IEC 61131-2 type 1; Positive logic (compliment of PWRR_A, compliment of PWRR_B) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1; Positive logic (LI1, LI2, LI3, LI4) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1 |
| Response time | <= 10 ms |
| Discrete output number | 2 |
| Discrete output type | Logic output(s) (LO1, LO2)24 V DC |
| Discrete output voltage | <= 30 V DC |
| Discrete output logic | Negative (LO1, LO2) conforming to EN/IEC 61131-2; Positive (LO1, LO2) conforming to EN/IEC 61131-2 |
| Contact bounce time | 1 ms for LI1...LI4 |
| Braking current | 50 mA |
| Response time on output | 1 ms (LO1, LO2) for discrete output(s) |
| Absolute accuracy error | < +/- 1 % 25 °C; < +/- 2 % over operating temperature range |
| Linearity error | < +/- 0.5 % |
| Analogue input type | ANA1+/ANA1-, ANA2+/ANA2- analog input: differential +/- 10 V, impedance: >= 10000 Ohm, resolution: 14 bits |
| Protection type | Inputs signal: against reverse polarity; Outputs signal: against short-circuits |
| Safety function | PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2; PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to ISO 13849-1 level d; PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to EN/IEC 61508 level SIL2; PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2 |
| Communication port protocol | Modbus; CANopen Motionbus; CANopen |
| Connector type | RJ45 (labelled CN4) for CANopen, CANopen Motionbus; RJ45 (labelled CN4) for Modbus; Spring terminals (labelled CN1) for CANopen, CANopen Motionbus |
| Method of access | Slave CANopen, CANopen Motionbus |
| Physical interface | 2-wire RS485 multidrop Modbus; RS422 for 1 A/B input(s), <= 400 kHz; RS422 for 1 CW/CCW input(s), <= 400 kHz; RS422 for 1 ESIM output input(s), <= 400 kHz; RS422 for 1 P/D input(s), <= 400 kHz |
| Transmission rate | 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen, CANopen Motionbus; 9600, 19200, 38400 bps for Modbus |
| Data format | 8 bits, no parity, 1 or 2 stop for Modbus; 8 bits, odd or even parity, 1 stop for Modbus |
| Number of addresses | 1…127 for CANopen, CANopen Motionbus; 1…247 for Modbus |
| Communication service | 1 receive SDO + 1 transmit SDO for CANopen Motionbus; 2 PDO for CANopen Motionbus; 2 receive SDO + 2 transmit SDO for CANopen; 3 PDO + 1 configurable mapping PDO for CANopen; CiA DSP 402 profile for CANopen; CiA DSP 402 profile for CANopen Motionbus; Communication monitoring for Modbus; Diagnostics (08) for Modbus; Read device identification (43) for Modbus; Read holding registers (03) for Modbus; Read/write multiple registers (23) for Modbus; Write multiple registers (16) for Modbus; Write single register (06) for Modbus |
| diagnostics | Drive voltage: 1 LED (red); Error: 1 LED (CANopen); RUN: 1 LED (CANopen) |
| Signalling function | Display of faults integrated 7-segment display terminal |
| max nodes number | 31 for Modbus |
| Input resistance | 5 kOhm |
| Marking | CE |
| Type of cooling | Fan |
| Operating position | Vertical +/- 10 degree |
| Net weight | 1.4 kg |
Environment
| EMC filter | Integrated |
| Electromagnetic compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 |
| Standards | EN/IEC 61800-3; EN/IEC 50178; EN/IEC 61800-5-1 |
| Product certifications | cUL; UL |
| IP degree of protection | IP20 on upper part with protective cover removed conforming to EN/IEC 60529; IP20 on upper part with protective cover removed conforming to EN/IEC 61800-5-1; IP41 on upper part with protective cover in place conforming to EN/IEC 60529; IP41 on upper part with protective cover in place conforming to EN/IEC 61800-5-1 |
| Vibration resistance | 1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6; 1.5 mm peak to peak (f= 3…13 Hz) conforming to EN/IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to EN/IEC 60028-2-27 |
| Pollution degree | 2 conforming to EN/IEC 61800-5-1 |
| Environmental characteristic | Classes 3C1 conforming to IEC 60721-3-3 |
| Relative humidity | Class 3K3 (5 to 93 %) without condensation conforming to IEC 60721-3-3 |
| Ambient air temperature for operation | 0…50 °C |
| Ambient air temperature for storage | -25…70 °C |
| Operating altitude | <= 1000 m without derating; > 1000...2000 m with conditions |
Downloads & documentation
Official documents from Schneider Electric, downloaded directly from the manufacturer.
Data sheets & manuals
| Product data sheet LXM05AD17M2 |
More Schneider Electric parts
Available on requestmotion servo drive LXM05A - 0.75kW - 200..240 V - 1-phase - with EMC filter
Available on requestmotion servo drive LXM05A - 0.75kW - 200..240 V - 3-phase - with EMC filter
Available on requestmotion servo drive LXM05A - 1.4 kW - 380..480 V - 3-phase - with EMC filter
Available on requestmotion servo drive LXM05A - 0.65kW - 110..120 V - 1-phase - with EMC filter
Available on requestmotion servo drive LXM05A - 1.4 kW - 200..240 V - 3-phase with EMC filter
Available on requestmotion servo drive LXM05A - 2 kW - 380..480 V - 3-phase - with EMC filter
Available on requestmotion servo drive LXM05A - 0.85kW - 110..120 V - 1-phase - with EMC filter
Available on requestmotion servo drive LXM05A - 2.5 kW - 200..240 V - 1-phase - with EMC filter