Available on request

Schneider Electric ATV71EXC5C40Y – enclosed variable speed drive ATV71 Plus - 400 kW - 690 V - IP54

MPN: ATV71EXC5C40Y · Brand: Schneider Electric
Price on request

Discontinued by Schneider Electric — we can still source the original ATV71EXC5C40Y (new, used or refurbished, subject to availability). Request a quote below.

Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryAltivar 71 Plus
LifecycleDiscontinued
Warranty12-month (new) · 3-month (used/refurbished)
UPC / EAN3389118333581
DatasheetManufacturer datasheet ↗

Shipping & availability

Can I still buy the ATV71EXC5C40Y now that it is discontinued?

Yes. Schneider Electric has discontinued the ATV71EXC5C40Y, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.

When can ATV71EXC5C40Y be shipped?

ATV71EXC5C40Y is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up ATV71EXC5C40Y in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for ATV71EXC5C40Y and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ATV71EXC5C40Y, subject to availability and destination.

Schneider Electric ATV71EXC5C40Y — enclosed variable speed drive ATV71 Plus - 400 kW - 690 V - IP54 (Altivar 71 Plus). Discontinued by Schneider Electric. PartnerPLC sources discontinued and surplus Schneider Electric automation parts — request a quote for price, condition and lead time.

Specifications

Main

Range of productAltivar 71 Plus
Product or component typeVariable speed drive
Device short nameATV71 Plus
Product destinationSynchronous motors; Asynchronous motors
Product specific applicationComplex, high-power machines
Assembly styleIn floor-standing enclosure compact version
product compositionATV71HC40Y drive on heatsink; Terminals/bars for motor connection; A line choke; A switch and fast-acting semi-conductor fuses; An IP65 remote mounting kit for graphic display terminal; A wired ready-assembled Sarel Spacial 6000 enclosure
EMC filterIntegrated
Network number of phases3 phases
rated supply voltage690 V +/- 10 %
Supply voltage limits621…759 V
Supply frequency50...60 Hz +/- 5 %
Network frequency47.5...63 Hz
Motor power kW400 kW at 690 V
Line current409 A for 690 V / 400 kW

Complementary

Apparent power489 kVA for 690 V / 400 kW
Prospective line Isc100 kA with external fuses
Continuous output current420 A at 2.5 kHz, 690 V / 400 kW
Maximum transient current630 A for 60 s / 400 kW
Speed drive output frequency0…500 Hz
Nominal switching frequency2.5 kHz
Switching frequency2.5...4.9 kHz with derating factor; 2...4.9 kHz adjustable
Speed range1…100 in open-loop mode, without speed feedback
Speed accuracy+/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn; +/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
Torque accuracy+/- 15 % in open-loop mode, without speed feedback; +/- 5 % in closed-loop mode with encoder feedback
Transient overtorque170 % of nominal motor torque +/- 10 % for 60 s; 220 % of nominal motor torque +/- 10 % for 2 s
Braking torque<= 150 % with braking or hoist resistor; 30 % without braking resistor
Asynchronous motor control profileFlux vector control without sensor, standard; Voltage/frequency ratio, 5 points; Flux vector control without sensor, ENA (energy Adaptation) system; Voltage/frequency ratio - Energy Saving, quadratic U/f; Flux vector control without sensor, 2 points; Flux vector control with sensor, standard; Voltage/frequency ratio, 2 points
Synchronous motor control profileVector control with sensor, standard; Vector control without sensor, standard
Regulation loopAdjustable PI regulator
Motor slip compensationSuppressable; Adjustable; Automatic whatever the load; Not available in voltage/frequency ratio (2 or 5 points)
Overvoltage categoryClass 3 conforming to EN 50178
Local signallingLCD display unit for operation function, status and configuration
Output voltage<= power supply voltage
IsolationElectrical between power and control
type of cable for external connectionIEC cable at 40 °C, copper 70 °C / PVC
Electrical connectionTerminal - 2.5 mm² / 14 AWG (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) entry from the bottom; Bar M12 - 4 x 300 mm² (L1/R, L2/S, L3/T) entry from the bottom; Bar M12 - 4 x 240 mm² (U/T1, V/T2, W/T3) entry from the bottom
Motor recommanded cable cross section2 (3 x 120) mm²
Short-circuit protection630 A fuse protection type gI - power supply upstream
SupplyExternal supply: 24 V DC (19…30 V), <1 A; Internal supply for reference potentiometer: 10 V DC (10…11 V), <10 mA; Internal supply: 24 V DC (21…27 V), <100 mA
Analogue input number2
Analogue input typeAI2 software-configurable voltage: 0...10 V DC, 24 V max, impedance: 30000 Ohm, sampling time: 1.5…2.5 ms, resolution: 11 bits; AI1-/Al1+ bipolar differential voltage: +/- 10 V DC, 24 V max, sampling time: 1.5…2.5 ms, resolution: 11 bits + sign; AI2 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, sampling time: 1.5…2.5 ms, resolution: 11 bits
Analogue output number1
Analogue output typeSoftware-configurable voltage: (AO1) 0...10 V DC - 470 Ohm - sampling time: 1.5…2.5 ms - resolution: 10 bits; Software-configurable current: (AO1) 0...20 mA/4...20 mA - 500 Ohm - sampling time: 1.5…2.5 ms - resolution: 10 bits
Discrete output number2
Discrete output typeConfigurable relay logic: (R1A, R1B, R1C)NO/NC - 6.5...7.5 ms - 100000 cycles; Configurable relay logic: (R2A, R2B)NO - 6.5...7.5 ms - 100000 cycles
Minimum switching current3 mA at 24 V DC (configurable relay logic)
Maximum switching current5 A at 250 V AC on resistive load - cos phi = 1 (R1, R2); 5 A at 30 V DC on resistive load - L/R = 0 ms (R1, R2); 2 A at 250 V AC on inductive load - cos phi = 0.4 (R1, R2); 2 A at 30 V DC on inductive load - L/R = 7 ms (R1, R2)
Discrete input number7
Discrete input typeProgrammable (LI1...LI5) at 24 V DC <= 30 V level 1 PLC 3.5 kOhm (duration=1.5…2.5 ms); Switch-configurable (LI6) at 24 V DC <= 30 V level 1 PLC 1.5 kOhm (duration=1.5…2.5 ms); Safety input (PWR) at 24 V DC <= 30 V 1.5 kOhm
Discrete input logicPositive logic (source) (LI1...LI6), 0...5 V (state 0), 11...30 V (state 1); Negative logic (sink) (LI1...LI6), 16...30 V (state 0), 0...10 V (state 1); Positive logic (source) (PWR), 0...2 V (state 0), 17...30 V (state 1)
Acceleration and deceleration rampsAutomatic adaptation of ramp if braking capacity exceeded, by using resistor; S, U or customized; Linear adjustable separately from 0.01 to 9000 s
Braking to standstillBy DC injection
Protection typeAgainst exceeding limit speed: drive; Against input phase loss: drive; Break on the control circuit: drive; Input phase breaks: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Overcurrent between output phases and earth: drive; Overheating protection: drive; Overvoltages on the DC bus: drive; Short-circuit between motor phases: drive; Thermal protection: drive; Input phase breaks: motor; Power removal: motor; Thermal protection: motor
Dielectric strength3110 V DC between earth and power terminals; 5345 V DC between control and power terminals
Insulation resistance> 1 mOhm 500 V DC for 1 minute to earth
Frequency resolutionAnalog input: 0.024/50 Hz; Display unit: 0.1 Hz
Communication port protocolModbus; CANopen
Connector type1 RJ45 (on front face) for Modbus; 1 RJ45 (on terminal) for Modbus; Male SUB-D 9 on RJ45 for CANopen
Physical interface2-wire RS 485 for Modbus
Transmission frameRTU for Modbus
Transmission rate4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal; 9600 bps, 19200 bps for Modbus on front face; 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
Data format8 bits, 1 stop, even parity for Modbus on front face; 8 bits, odd even or no configurable parity for Modbus on terminal
Type of polarizationNo impedance for Modbus
Number of addresses1…247 for CANopen; 1…247 for Modbus
Method of accessSlave CANopen
Option cardCommunication card for CC-Link; Communication card for DeviceNet; Communication card for EtherNet/IP; Communication card for Fipio; Communication card for Interbus-S; Communication card for Modbus Plus; Communication card for Modbus/Uni-Telway; Communication card for Profibus DP; Communication card for Profibus DP V1; Communication card for Modbus TCP/IP; Controller inside programmable card; Basic I/O extension card; Extended I/O extension card; Encoder interface cards
options for enclosure configurationSafe standstill for power circuit; PTC relay for power circuit; Pt100 relay for power circuit; Insulation monitoring for power circuit; Design for IT networks for power circuit; External 230 V supply terminals for power circuit; Buffer voltage 24 V DC power supply for power circuit; External 24 V DC supply terminals for power circuit; Enclosure lighting for power circuit; Key switch (local/remote) for power circuit; Motor heating for power circuit; External motor fan for power circuit; Voltmeter for power circuit; Door handle for main switch for power circuit; Circuit breaker for power circuit; Line contactor for power circuit; Ammeter for power circuit; Enclosure heating for power circuit; Motor choke for power circuit; Cable entry via the top for power circuit; Enclosure plinth for power circuit; Braking unit for power circuit; Door handle for circuit breaker for power circuit; Control terminals for control circuit; Adaptor for 115 V logic inputs for control circuit; Relay output C/O for control circuit; Isolated amplifier for control circuit
Operating positionVertical +/- 10 degree
Colour of enclosureLight grey (RAL 7035)
Height2262 mm
Width1200 mm
Depth642 mm
Net weight855 kg

Environment

Electromagnetic compatibility1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Pollution degree3 conforming to EN/IEC 61800-5-1
IP degree of protectionIP54
Vibration resistance0.6 gn (f= 10…200 Hz) conforming to EN/IEC 60068-2-6; 1.5 mm (f= 3…10 Hz) conforming to EN/IEC 60068-2-6; 3M3 conforming to EN/IEC 60721-3-3
Shock resistance4 gn for 11 ms conforming to EN/IEC 60068-2-27; 3M2 conforming to EN/IEC 60721-3-3
Noise level79 dB conforming to 86/188/EEC
Environmental characteristicWithout condensation: 3C2 conforming to IEC 60721-3-3; Without condensation: 3K3 conforming to IEC 60721-3-3; Without condensation: 3S2 conforming to IEC 60721-3-3
Relative humidity0…95 %
Ambient air temperature for operation0…40 °C (without derating); 40…50 °C (with current derating of 0.6 % per °C)
Ambient air temperature for storage-25…70 °C
Volume of cooling air2400 m3/h
Operating altitude<= 1000 m without derating; 1000...3000 m with current derating 1 % per 100 m
StandardsEN/IEC 61800-5-1; EN 61800-3 environments 2 category C3; EN 61800-3 environments 1 category C3; EN 55011 class A group 2; EN/IEC 61800-3
Product certificationsGOST; ATEX
MarkingCE

Downloads & documentation

Official documents from Schneider Electric, downloaded directly from the manufacturer.

Data sheets & manuals

Product data sheet ATV71EXC5C40YPDF
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Schneider Electric parts

enclosed variable speed drive ATV71 Plus - 315 kW - 690 V - IP54Available on requestenclosed variable speed drive ATV71 Plus - 315 kW - 690 V - IP54
MPN: ATV71EXC5C31Y · Schneider Electric
Price on request
Request a quote
enclosed variable speed drive ATV71 Plus - 400 kW - 500 V - IP54Available on requestenclosed variable speed drive ATV71 Plus - 400 kW - 500 V - IP54
MPN: ATV71EXC5C40N · Schneider Electric
Price on request
Request a quote
enclosed variable speed drive ATV71 Plus - 400 kW - 400 V - IP54Available on requestenclosed variable speed drive ATV71 Plus - 400 kW - 400 V - IP54
MPN: ATV71EXC5C40N4 · Schneider Electric
Price on request
Request a quote
enclosed variable speed drive ATV71 Plus-LH - 400 KW - 400V - IP54- low harmonicAvailable on requestenclosed variable speed drive ATV71 Plus-LH - 400 KW - 400V - IP54- low harmonic
MPN: ATV71EXC5C40N4H · Schneider Electric
Price on request
Request a quote
enclosed variable speed drive ATV71 Plus - 500 kW - 500 V - IP54Available on requestenclosed variable speed drive ATV71 Plus - 500 kW - 500 V - IP54
MPN: ATV71EXC5C50N · Schneider Electric
Price on request
Request a quote
enclosed variable speed drive ATV71 Plus - 500 kW - 400 V - IP54Available on requestenclosed variable speed drive ATV71 Plus - 500 kW - 400 V - IP54
MPN: ATV71EXC5C50N4 · Schneider Electric
Price on request
Request a quote
enclosed variable speed drive ATV71 Plus-LH - 500 KW - 400V - IP54- low harmonicAvailable on requestenclosed variable speed drive ATV71 Plus-LH - 500 KW - 400V - IP54- low harmonic
MPN: ATV71EXC5C50N4H · Schneider Electric
Price on request
Request a quote
enclosed variable speed drive ATV71 Plus - 500 kW - 690 V - IP54Available on requestenclosed variable speed drive ATV71 Plus - 500 kW - 690 V - IP54
MPN: ATV71EXC5C50Y · Schneider Electric
Price on request
Request a quote