Schneider Electric ATV61WU55N4C – variable speed drive ATV61 - 5.5kW 7.5HP - 380...480V - EMC filter - IP54
Discontinued by Schneider Electric — we can still source the original ATV61WU55N4C (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Altivar 61 |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Country of origin | FR |
| UPC / EAN | 3389119406055 |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
Can I still buy the ATV61WU55N4C now that it is discontinued?
Yes. Schneider Electric has discontinued the ATV61WU55N4C, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can ATV61WU55N4C be shipped?
ATV61WU55N4C is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up ATV61WU55N4C in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for ATV61WU55N4C and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ATV61WU55N4C, subject to availability and destination.
Schneider Electric ATV61WU55N4C — variable speed drive ATV61 - 5.5kW 7.5HP - 380...480V - EMC filter - IP54 (Altivar 61). Discontinued by Schneider Electric. PartnerPLC sources discontinued and surplus Schneider Electric automation parts — request a quote for price, condition and lead time.
Specifications
Main
| Range of product | Altivar 61 |
| Product or component type | Variable speed drive |
| Product specific application | Pumping and ventilation machine |
| Component name | ATV61 |
| Motor power kW | 5.5 kW, 3 phases at 380...480 V |
| Motor power hp | 7.5 hp, 3 phases at 380...480 V |
| power supply voltage | 380...480 V - 15...10 % |
| supply number of phases | 3 phases |
| Line current | 11.4 A for 380 V 3 phases 5.5 kW / 7.5 hp; 9.2 A for 480 V 3 phases 5.5 kW / 7.5 hp |
| EMC filter | Class C1 EMC filter integrated |
| Assembly style | Enclosed |
| Apparent power | 7.5 kVA at 380 V 3 phases 5.5 kW / 7.5 hp |
| maximum prospective line Isc | 22 kA for 3 phases |
| Maximum transient current | 13.2 A for 60 s, 3 phases |
| Nominal switching frequency | 8 kHz |
| Switching frequency | 2...16 kHz adjustable; 8...16 kHz with derating factor |
| asynchronous motor control | Flux vector control without sensor, standard; Voltage/frequency ratio - Energy Saving, quadratic U/f; Voltage/frequency ratio, 5 points; Voltage/frequency ratio, 2 points |
| Synchronous motor control profile | Vector control without sensor, standard |
| Communication port protocol | Modbus; CANopen |
| Type of polarization | No impedance for Modbus |
| Option card | Communication card for APOGEE FLN; Communication card for BACnet; Communication card for CC-Link; Controller inside programmable card; Communication card for DeviceNet; Communication card for EtherNet/IP; Communication card for Fipio; I/O extension card; Communication card for Interbus-S; Communication card for LonWorks; Communication card for METASYS N2; Communication card for Modbus Plus; Communication card for Modbus TCP; Communication card for Modbus/Uni-Telway; Multi-pump card; Communication card for Profibus DP; Communication card for Profibus DP V1 |
Complementary
| Product destination | Synchronous motors; Asynchronous motors |
| power supply voltage limits | 323…528 V |
| power supply frequency | 50...60 Hz - 5...5 % |
| power supply frequency limits | 47.5...63 Hz |
| Continuous output current | 11 A at 8 kHz, 460 V - 3 phases; 12 A at 8 kHz, 380 V - 3 phases |
| Output frequency | 0.1…599 Hz |
| Speed range | 1…100 in open-loop mode, without speed feedback |
| Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback |
| Torque accuracy | +/- 15 % in open-loop mode, without speed feedback |
| Transient overtorque | 130 % of nominal motor torque +/- 10 % for 60 s |
| Braking torque | <= 125 % with braking resistor; 30 % without braking resistor |
| Regulation loop | Frequency PI regulator |
| Motor slip compensation | Adjustable; Automatic whatever the load; Can be suppressed; Not available in voltage/frequency ratio (2 or 5 points) |
| diagnostic | 1 LED (red) for drive voltage |
| Output voltage | <= power supply voltage |
| electrical isolation | Between power and control terminals |
| type of cable for mounting in an enclosure | With an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC; With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC; Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC; Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR |
| Electrical connection | Terminal 2.5 mm² / 14 AWG (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR); Terminal 6 mm² / 8 AWG (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
| Tightening torque | 0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR); 1.4 N.m, 12.3 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
| Supply | Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC, +/- 5 %, <10 mA with overload and short-circuit protection; Internal supply: 24 V DC (21…27 V), <200 mA with overload and short-circuit protection; External supply: 24 V DC (19…30 V) |
| Analogue input number | 2 |
| Analogue input type | AI1-/Al1+ bipolar differential voltage: +/- 10 V DC 24 V max, resolution 11 bits + sign; AI2 software-configurable current: 0...20 mA, impedance: 242 Ohm, resolution 11 bits; AI2 software-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits |
| sampling time | 2 ms +/- 0.5 ms (AI1-/Al1+) - analog input; 2 ms +/- 0.5 ms (Al2) - analog input; 2 ms +/- 0.5 ms (AO1) - analog output; 2 ms +/- 0.5 ms (LI1...LI5) - discrete input; 2 ms +/- 0.5 ms (LI6)if configured as logic input - discrete input |
| absolute accuracy precision | +/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C; +/- 0.6 % (AI2) for a temperature variation 60 °C; +/- 1 % (AO1) for a temperature variation 60 °C |
| Linearity error | +/- 0.15 % of maximum value (AI1-/Al1+); +/- 0.15 % of maximum value (AI2); +/- 0.2 % (AO1) |
| Analogue output number | 1 |
| Analogue output type | AO1 software-configurable current, analogue output range 0...20 mA, impedance: 500 Ohm, resolution 10 bits; AO1 software-configurable voltage, analogue output range 0...10 V DC, impedance: 470 Ohm, resolution 10 bits; AO1 software-configurable logic output 10 V, 20 mA |
| Discrete output number | 2 |
| Discrete output type | Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles; Configurable relay logic: (R2A, R2B) NO - 100000 cycles |
| maximum response time | <= 100 ms in STO (Safe Torque Off); R1A, R1B, R1C <= 7 ms, tolerance +/- 0.5 ms; R2A, R2B <= 7 ms, tolerance +/- 0.5 ms |
| Minimum switching current | 3 mA at 24 V DC for configurable relay logic |
| Maximum switching current | R1, R2: 2 A at 250 V AC inductive load, cos phi = 0.4 and L/R = 7 ms; R1, R2: 2 A at 30 V DC inductive load, cos phi = 0.4 and L/R = 7 ms; R1, R2: 5 A at 250 V AC resistive load, cos phi = 1 and L/R = 0 ms; R1, R2: 5 A at 30 V DC resistive load, cos phi = 1 and L/R = 0 ms |
| Discrete input number | 7 |
| Discrete input type | Programmable (LI1...LI5)24 V DC (<= 30 V), with level 1 PLC - 3500 Ohm; Switch-configurable (LI6)24 V DC (<= 30 V), with level 1 PLC - 3500 Ohm; Switch-configurable PTC probe (LI6)0…6 probes - 1500 Ohm; Safety input (PWR)24 V DC (<= 30 V) - 1500 Ohm |
| Discrete input logic | Negative logic (sink) (LI1...LI5), > 16 V (state 0), < 10 V (state 1); Positive logic (source) (LI1...LI5), < 5 V (state 0), > 11 V (state 1); Negative logic (sink) (LI6)if configured as logic input, > 16 V (state 0), < 10 V (state 1); Positive logic (source) (LI6)if configured as logic input, < 5 V (state 0), > 11 V (state 1) |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 9000 s; S, U or customized; Automatic adaptation of ramp if braking capacity exceeded, by using resistor |
| Braking to standstill | By DC injection |
| Protection type | Against exceeding limit speed: drive; Against input phase loss: drive; Break on the control circuit: drive; Input phase breaks: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Overcurrent between output phases and earth: drive; Overheating protection: drive; Overvoltages on the DC bus: drive; Power removal: drive; Short-circuit between motor phases: drive; Thermal protection: drive; Motor phase break: motor; Power removal: motor; Thermal protection: motor |
| Insulation resistance | > 1 mOhm 500 V DC for 1 minute to earth |
| Frequency resolution | Analog input: 0.024/50 Hz; Display unit: 0.1 Hz |
| Connector type | 1 RJ45 (on front face) for Modbus; 1 RJ45 (on terminal) for Modbus; Male SUB-D 9 on RJ45 for CANopen |
| Physical interface | 2-wire RS 485 for Modbus |
| Transmission frame | RTU for Modbus |
| Transmission rate | 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal; 9600 bps, 19200 bps for Modbus on front face; 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen |
| Data format | 8 bits, 1 stop, even parity for Modbus on front face; 8 bits, odd even or no configurable parity for Modbus on terminal |
| Number of addresses | 1…127 for CANopen; 1…247 for Modbus |
| Method of access | Slave CANopen |
| Marking | CE |
| Operating position | Vertical +/- 10 degree |
| Net weight | 23 kg |
| Width | 240 mm |
| Height | 490 mm |
| Depth | 286 mm |
Environment
| Noise level | 54.5 dB conforming to 86/188/EEC |
| Dielectric strength | 3535 V DC between earth and power terminals; 5092 V DC between control and power terminals |
| Electromagnetic compatibility | Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| Standards | IEC 61800-3 environments 1 category C1; UL Type 12; IEC 61800-3; IEC 60721-3-3 class 3C1; EN 55011 group 1 class B; IEC 60721-3-3 class 3S2; IEC 61800-3 environments 2 category C1; IEC 61800-5-1 |
| Product certifications | CSA; GOST; NOM 117; DNV; UL; C-Tick |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| degree of proctection | IP54 conforming to IEC 60529; IP54 conforming to IEC 61800-5-1; IP54 conforming to UL Type 12 |
| Vibration resistance | 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6; 1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3 |
| Ambient air temperature for operation | -10…40 °C (without derating); -10…50 °C (with derating factor) |
| Ambient air temperature for storage | -25…70 °C |
| Operating altitude | <= 1000 m without derating; 1000...3000 m with current derating 1 % per 100 m |
Downloads & documentation
Official documents from Schneider Electric, downloaded directly from the manufacturer.
Data sheets & manuals
| Product data sheet ATV61WU55N4C |
More Schneider Electric parts
Available on requestATV61 IP54 4kW 3 ph 380...480V class B EMC
Available on requestATV61 IP54 4kW 3 ph 380...480V class A EMC
Available on requestvariable speed drive ATV61 - 5.5kW 7.5HP - 380...480V - EMC filter - IP54
Available on requestvariable speed drive ATV61 - 5.5kW 7.5HP - 380...480V - EMC filter - IP54
Available on requestATV61 IP54 5.5kW 3 ph 380-480V class B EMC
Available on requestATV61 5.5kW 400V 3PH EMC Class A IP54 Enclosure
Available on requestvariable speed drive ATV61 - 7.5kW 10HP - 380...480V - EMC filter - IP54
Available on requestvariable speed drive ATV61 - 7.5kW 10HP- 380...480V - EMC filter - IP54