Schneider Electric ATV600SYSTEM – Variable speed drive, Altivar Process ATV600, Enclosure full ETO
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Altivar Process ATV600 |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
When can ATV600SYSTEM be shipped?
ATV600SYSTEM is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up ATV600SYSTEM in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for ATV600SYSTEM and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ATV600SYSTEM, subject to availability and destination.
Schneider Electric ATV600SYSTEM — Variable speed drive, Altivar Process ATV600, Enclosure full ETO. PartnerPLC sources new and surplus Schneider Electric automation parts — request a quote for price, condition and lead time.
Specifications
Main
| Range of product | Altivar Process ATV600 |
| Device short name | ATV600 |
| Product or component type | Variable speed drive |
| Device application | Industrial application |
| Assembly style | In floor-standing enclosure compact version |
| Function available | Customised enclosure colour; Customised option card; Customised cable entry; Customised provided equipment |
| Provided equipment | Enclosure Spacial SF; Graphical operating panel in the enclosure door; Frequency inverter; Main switch; Line choke; Terminal block main supply; Terminal block motor; Dv/dt filter choke |
| cable entry | Top; Bottom |
| Colour of enclosure | Light grey (RAL 7035) |
| IP degree of protection | IP23 conforming to IEC 61800-5-1; IP54 |
| Type of cooling | Forced convection |
| [Us] rated supply voltage | 380...415 V - 10...6 %; 440 V - 10...6 %; 480 V - 10...6 %; 500 V - 10...6 %; 600 V - 10...6 %; 690 V - 10...6 % |
| Supply frequency | 50/60 Hz +/-5 % |
| Network number of phases | 3 phases |
| Overvoltage category | III |
| Asynchronous motor control profile | Optimized torque mode; Variable torque standard; Constant torque standard |
| Synchronous motor control profile | Permanent magnet motor |
| Output voltage | <= power supply voltage |
| Permissible temporary current boost | 1.1 x In during 60 s (normal duty); 1.5 x In during 60 s (heavy duty) |
| Nominal switching frequency | 2.5 kHz |
| Switching frequency | 2...8 kHz adjustable with derating factor |
| Speed drive output frequency | 0.1…500 Hz |
| Continuous output current | 173…1140 A at 2.5 kHz, heavy duty; 211…1420 A at 2.5 kHz, normal duty |
| Maximum THDI | <36 % full load conforming to IEC 61000-3-12 |
| Prospective line Isc | 50 kA for 100 ms |
| Motor recommanded cable cross section | 6 x (3 x 185 mm²) (normal duty); 5 x (3 x 240 mm²) (normal duty); 6 x (3 x 120 mm²) (heavy duty); 5 x (3 x 185 mm²) (heavy duty) |
| Width | 400…1400 mm |
| Height | 2150 mm |
| Depth | 664 mm |
| Net weight | 300…1200 kg |
| number of preset speeds | 16 preset speeds |
| Communication port protocol | EtherNet/IP with; Modbus serial with; Modbus TCP with |
| Safety function | STO (safe torque off), level SIL 3 for <= 100 ms |
Complementary
| Product destination | asynchronous motors; synchronous motors |
| Energy efficiency ratio | 0.98 |
| Electrical connection | Control: removable screw terminals 0.5...1.5 mm²; Main supply: M12 bar; Motor: M12 bar |
| Cable composition | 6 x (3 x 240 mm²) (normal duty); 8 x (3 x 150 mm²) (normal duty); 5 x (3 x 185 mm²) (heavy duty); 6 x (3 x 150 mm²) (heavy duty) |
| Option card | Slot A: communication module for Profibus DP V1; Slot A: communication module for PROFINET; Slot A: communication module for DeviceNet; Slot A: communication module for Modbus TCP/EtherNet/IP; Slot A: communication module for CANopen daisy chain RJ45; Slot A: communication module for CANopen SUB-D 9; Slot A: communication module for CANopen screw terminals; Slot A/slot B: digital and analog I/O extension module; Slot A/slot B: output relay extension module |
| Motor slip compensation | Can be suppressed; Automatic whatever the load; Adjustable; Not available in permanent magnet motor law |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 9000 s; S, U or customized |
| Braking to standstill | By DC injection |
| Protection type | Motor: thermal protection; Motor: safe torque off; Motor: motor phase break; Drive: thermal protection; Drive: safe torque off; Drive: overheating; Drive: overcurrent (between output phases and earth); Drive: overload (output); Drive: short-circuit protection; Drive: motor phase break; Drive: overvoltage (DC bus); Drive: line supply overvoltage; Drive: line supply undervoltage; Drive: line supply phase loss; Drive: overspeed; Drive: break on the control circuit; Drive: short-circuit protection with semi-conductor fuse (main supply); Drive: fan monitoring |
| Frequency resolution | Display unit: 0.1 Hz; Analog input: 0.012/50 Hz |
| Connector type | RJ45 for Modbus serial on the control block; RJ45 for Ethernet IP/Modbus TCP on the control block |
| Physical interface | 2-wire RS 485 for Modbus serial |
| Transmission frame | RTU for Modbus serial |
| Transmission rate | 10/100 Mbit/s for Ethernet IP/Modbus TCP; 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
| Exchange mode | Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
| Data format | 8 bits, configurable odd, even or no parity for Modbus serial |
| Type of polarization | No impedance for Modbus serial |
| Number of addresses | 1…247 for Modbus serial |
| Method of access | Slave Modbus TCP |
| Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection; Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection; Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection |
| Local signalling | LCD display unit front door operation function, status and configuration |
| Analogue input number | 3 |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits; AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits |
| Discrete input number | 8 |
| Discrete input type | DI1...DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm; DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V); STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm |
| Input compatibility | DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2; DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68; STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2 |
| Discrete input logic | Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1); Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1); Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1); Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) |
| Analogue output number | 2 |
| Analogue output type | Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits; Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits |
| Sampling duration | 2 ms +/- 0.5 ms (DI1...DI4) - discrete input; 5 ms +/- 1 ms (DI5, DI6) - discrete input; 5 ms +/- 1 ms (AI1, AI2, AI3) - analog input; 10 ms +/- 1 ms (AQ1, AQ2) - analog output |
| Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input; +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
| Linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input; AQ1, AQ2: +/- 0.2 % for analog output |
| Relay output number | 3 |
| Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles; Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles; Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
| Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC; Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC; Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Isolation | Between power and control terminals |
| Insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
| Operating position | Vertical +/- 10 degree |
| Ambient air temperature for storage | -25…70 °C |
| Standards | IEC 61800-5-1; IEC 61800-3; IEC 60204-1; IEC 61800-2 |
| Marking | CE |
Environment
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Vibration resistance | 1.5 mm peak to peak (f= 3…10 Hz) conforming to IEC 60068-2-6; 0.6 gn (f= 10…200 Hz) conforming to IEC 60068-2-6; 3M3 conforming to IEC 60721-3-3 |
| Shock resistance | 4 gn for 11 ms conforming to IEC 60068-2-27; 3M2 conforming to IEC 60721-3-3 |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
| Ambient air temperature for operation | -10…0 °C without derating (with option enclosure heating); 0…40 °C without derating; 40…50 °C with derating factor |
| Operating altitude | <= 1000 m without derating; 1000...2000 m with current derating 1 % per 100 m; 2000...3800 m with current derating 1 % per 100 m for TT earthing system; 2000...3800 m with current derating 1 % per 100 m for TN earthing system; 2000...3800 m with current derating 1 % per 100 m for IT earthing system; 3800...4800 m with current derating 1 % per 100 m for TT earthing system; 3800...4800 m with current derating 1 % per 100 m for TN earthing system |
| Environmental characteristic | Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3; Dust pollution resistance class 3S3 conforming to IEC 60721-3-3; Humidity resistant class 3K3 conforming to IEC 60721-3-3 |
| Product certifications | ATEX; C-Tick; EAC |
Downloads & documentation
Official documents from Schneider Electric, downloaded directly from the manufacturer.
Data sheets & manuals
| Product data sheet ATV600SYSTEM |
More Schneider Electric parts
Available on requestadjustable speed drive ATV-58P with base plate - 3 kW - Class A EMC filter
Available on requestadjustable speed drive ATV-58P with base plate - 4 kW - Class A EMC filter
Available on requestadjustable speed drive ATV-58P with base plate - 5.5 kW - Class A EMC filter
Available on requestadjustable speed drive ATV-58P with base plate - 5.5 kW - Class A EMC filter
Available on requestvariable speed drive ATV61 - 0.75kW 1HP - 380...480V - EMC filter - IP54
Available on requestvariable speed drive ATV61 - 11kW 15HP - 380...480V - EMC filter - IP54
Available on requestvariable speed drive ATV61 - 15kW 20HP - 380...480V - EMC filter - IP54
Available on requestvariable speed drive ATV61 - 18.5kW 25HP - 380...480V - EMC filter - IP54