Schneider Electric ATV08PU18M2X – ATV08 0,75 kW base plate without EMC - single phase
Discontinued by Schneider Electric — we can still source the original ATV08PU18M2X (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Altivar 08 |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| UPC / EAN | 3389110124293 |
| Recommended replacement | ATV12P075M2 |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
Can I still buy the ATV08PU18M2X now that it is discontinued?
Yes. Schneider Electric has discontinued the ATV08PU18M2X, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time. If you are planning an upgrade instead, Schneider Electric names the ATV12P075M2 as its successor — we can quote both.
When can ATV08PU18M2X be shipped?
ATV08PU18M2X is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up ATV08PU18M2X in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for ATV08PU18M2X and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ATV08PU18M2X, subject to availability and destination.
Schneider Electric ATV08PU18M2X — ATV08 0,75 kW base plate without EMC - single phase. Discontinued by Schneider Electric; the manufacturer's successor is ATV12P075M2. PartnerPLC sources discontinued and surplus Schneider Electric automation parts — request a quote for price, condition and lead time.
Specifications
Main
| Range of product | Altivar |
| Product or component type | Variable speed drive |
| Product specific application | Simple machine |
| Component name | ATV08 |
| Assembly style | On base plate |
| EMC filter | Without EMC filter |
| Network number of phases | Single phase |
| [Us] rated supply voltage | 200...240 V +/- 10 % |
| Supply frequency | 50...60 Hz - 5...5 % |
| Motor power kW | 0.75 kW |
| Motor power hp | 1 hp |
| Line current | 6 A at 230 V, Isc = 1 kA |
| Nominal output current | 4.6 A 4 kHz 230 V motor |
| Maximum transient current | 6.3 A for 60 s |
| Power dissipation in W | 43 W at nominal load |
| Asynchronous motor control profile | Sensorless flux vector control with PWM type motor control signal |
| Analogue input number | 1 |
Complementary
| Product destination | Asynchronous motors |
| Built-in fan | Without |
| Supply voltage limits | 180…264 V |
| Network frequency limits | 47.5…63 Hz |
| Speed drive output frequency | 0.5…200 Hz |
| Nominal switching frequency | 4 kHz |
| Switching frequency | 2...16 kHz adjustable; 4...16 kHz with derating factor |
| Speed range | 1…10 |
| Transient overtorque | 150...170 % of nominal motor torque |
| Regulation loop | Possible correction for machines with high resistive torque/inertia/fast cycles; Factory-set with the speed loop stability and gain; Adjustable frequency |
| Motor slip compensation | Adjustable; Preset in factory |
| Prospective line Isc | 1 kA |
| Output voltage | <= 2 x power supply voltage |
| Electrical connection | Control terminal 1.5 mm²; Power supply terminal 1.5 mm² |
| Insulation | Galvanic insulation between power and control terminals |
| Supply | Internal supply for logic inputs: 15 V 100 mA, protection type: overload and short-circuit protection; Internal supply for reference potentiometer (1 to 10 kOhm): 5 VDC 10 mA, protection type: overload and short-circuit protection |
| Analogue input type | Configurable current AI1 4...20 mA 500 Ohm with load in parallel; Configurable voltage AI1 0...5 V 50000 Ohm; Configurable current AI1 0...20 mA 500 Ohm; Configurable voltage AI1 0...10 V 50000 Ohm |
| Sampling duration | LI1...LI4: 20 ms discrete; AI1: 20 ms analog |
| Linearity error | : +/- 1 % for output |
| Discrete input number | 4 |
| Discrete input type | Assignable Ll1 forward 3500 Ohm 15 V 24 V; Assignable Ll2 reverse 3500 Ohm 15 V 24 V; Assignable Ll3/Ll4 4 preset speeds 3500 Ohm 15 V 24 V |
| Discrete input logic | Positive logic (source) (LI1...LI4), < 5 V (state 0), > 11 V (state 1) |
| Discrete output number | 2 |
| Discrete output type | Relay normally open R1 1 NO |
| Minimum switching current | R1A, R1C 10 mA at 24 V DC |
| Maximum switching current | 1.5 A 250 V AC inductive cos phi = 0.4 7 ms R1A, R1C; 1.5 A 30 V DC inductive cos phi = 0.4 7 ms R1A, R1C; 1.5 A 250 V AC resistive cos phi = 1 0 ms R1A, R1C; 1.5 A 30 V DC resistive cos phi = 1 0 ms R1A, R1C |
| Acceleration and deceleration ramps | Linear from 0 to 99.9 s |
| Braking to standstill | By DC injection |
| Protection type | Line supply overvoltage: drive; Line supply undervoltage: drive; Overheating protection: drive; Short-circuit between motor phases: drive; Thermal protection: motor; Overcurrent between output phases and earth: drive |
| Insulation resistance | >= 500 mOhm |
| Operating position | Vertical +/- 10 degree |
| CAD overall width | 72 mm |
| CAD overall height | 130 mm |
| CAD overall depth | 87 mm |
Environment
| Electromagnetic compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to EN/IEC 61000-4-5; Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4; Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3; Conducted and radiated emissions conforming to EN 55011 class B; Conducted and radiated emissions conforming to IEC/EN 61800-3 environments 1 and 2 |
| Standards | EN/IEC 61800-3 |
| Product certifications | CSA; UL |
| Marking | CE |
| IP degree of protection | IP20 |
| Relative humidity | 5…93 % without condensation conforming to IEC 60068-2-3; 5…93 % without dripping water conforming to IEC 60068-2-3 |
| Ambient air temperature for storage | -25…65 °C |
| Ambient air temperature for operation | 0…40 °C without derating; 40…60 °C with current derating 2.2 % per °C |
| Operating altitude | <= 1000 m without derating; > 1000 m with current derating 1 % per 100 m |
Downloads & documentation
Official documents from Schneider Electric, downloaded directly from the manufacturer.
Data sheets & manuals
| Product data sheet ATV08PU18M2X |
More Schneider Electric parts
Available on requestATV08 0,18 kW base plate without EMC - single phase
Available on requestATV08 0,37 kW base plate with EMC - single phase
Available on requestATV08 0,37 kW base plate without EMC - single phase
Available on requestATV08 0,75 kW base plate with EMC - single phase
Available on requestvariable speed drive ATV11 - 0.18kW - 120V 1-phase supply - IP20
Available on requestvariable speed drive ATV11 - 0.18kW - 120V 1-phase supply - IP20
Available on requestvariable speed drive ATV11 - 0.18kW - 230V 1-phase supply - IP20
Available on requestvariable speed drive ATV11 - 0.18kW - 230V 1-phase supply - IP20