Communication module, EcoStruxure I/O Smart Link, Modbus, RS485
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | EcoStruxure I/O Smart Link |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 188 kg |
Shipping & availability
When can A9XMSB11 be shipped?
A9XMSB11 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up A9XMSB11 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for A9XMSB11 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for A9XMSB11, subject to availability and destination.
This Acti 9 SmartLink Modbus Slave is a smart communication module with 11 channels. It communicates with the auxiliaries iACT24 for iCT contactors, iATL24 for iTL impulse relays, iOF+SD24 for iC60, iID, ARA, RCA & iSW-NA. It needs to be associated to a Master SmartLink SI B thanks to the Modbus RS485 connector. It is used to transfer data from Acti 9 devices to a PLC or network monitoring system thanks to the Ethernet connector. It communicates also with OF+SD24 for C60, C120, DPN, ID & C60H-DC, Ti24 for RCA iC60 & Reflex iC60. It is supplied with 1 power supply connector 24VDC, 2 bolts for mounting on Linergy FM80. The link is Modbus, RTU, RS485 serial connection. The transfer rate is self-adaptable from 9600 to 19200 baud. The Modbus addresing range is 1 to 99. It is a 4-pin connector type of bus. It is a plug-in connection. The maximum length of the bus is 1000m. The maximum cable length is 500m. The voltage power supply is 24VDC +/- 10%. The Maximum input current is 1,5A. The Maximum inrush current is 3A. The degree of protection is IP20. The pollution degree is 3. It complies with RoHS directive. The duration of saving memory is 10 years. The dimensions are (W) 359mm x (H) 23mm x (D) 42mm. The weigth is 195g. The operating temperature is -25°C to + 60°C and only +50°C if vertical mouting. The storage temperature is -40°C to + 80°C. This product complies with IEC/EN 61131-2 standard.
Specifications
Specifications
| Range of product | Acti9 |
| range of product | EcoStruxure |
| Product or component type | Smart communication module |
| Product name | EcoStruxure I/O Smart Link |
| Device short name | I/O Smart Link |
| Application type | Load control, Breaker status monitoring, Basic energy metering E |
| Number max of connected devices | Up to 11 wired devices |
| Group of channels | 1 group of 11 digital channels |
| Maximum supply current | 1.5 A |
| [Us] rated supply voltage | 24 V DC +/- 20 % |
| Connectivity to devices | Digital input and output, Pulse output meter |
| Communication service | Modbus server for RS485 |
| Web server | BMS controller compatible |
| Application specific I/O | Pulse totalising counter, Pulse converter |
| Protection type | Against reverse polarity for auxiliary supply, Against reverse polarity for input, Overvoltage at 33 V DC for digital output |
| Immunity to microbreaks | 10 ms |
| Reset | Factory reset on front face, By booted push-button, By address encoder, By plug in, plug out the power supply |
| Input/output type | 2 inputs + 1 output per digital channel |
| Input type | Current sink for digital input, 24 V DC +/- 20 % at 2.5 mA |
| Maximum permanent current | 5 mA for digital input |
| Electronic filtering time | 2 ms for digital input from state 0 to state 1 |
| Output type | Logic current source: 24 V - DC - 100 mA |
| Maximum voltage drop | <1 V at state 1 digital output |
| Inrush current | 0.5 A for digital output, 7 A for power supply |
| Local signalling | Communication: 1 LED (yellow), Status: 1 LED (green, orange and red) |
| Type of setting | Modbus address 01...99 for address encoders, Reset for address encoders, Reset for plug in, plug out the auxiliary supply |
| Mounting position | Horizontal and vertical on DIN rail |
| Colour | White (RAL 9003) |
| Location of connection | Front |
| Connections - terminals | Spring-loaded terminal Ti24 qty: 11 for digital input/output, ordered separately, Plug-in connector qty: 1 for supply circuit, Plug-in connector qty: 1 for communication bus |
| Clamping connection capacity | 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible with cable end for communication bus, 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible without cable end for communication bus, 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid with cable end for communication bus, 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid without cable end for communication bus, 1 x 0.2...1 x 1.5 mm², flexible with cable end for control, 1 x 0.2...1 x 1.5 mm², flexible without cable end for control, 1 x 0.2...1 x 1.5 mm², rigid with cable end for control, 1 x 0.2...1 x 1.5 mm², rigid without cable end for control, 2 x 0.2...2 x 1.5 mm², flexible with cable end for supply circuit, 2 x 0.2...2 x 1.5 mm², flexible without cable end for supply circuit, 2 x 0.2...2 x 1.5 mm², rigid with cable end for supply circuit, 2 x 0.2...2 x 1.5 mm², rigid without cable end for supply circuit |
| Wire stripping length | Control: 10 mm, Supply circuit: 7 mm, Communication bus: 7 mm |
| Communication network type | RS485 Modbus RTU client/server SUB-D 9 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps |
| 9 mm pitches | 0 useful |
| Height | 22.5 mm |
| Width | 359 mm |
| Depth | 42 mm |
| Net weight | 188 g |
| Provided equipment | Set of 1 bus connector, Set of 1 power supply connector, Set of 2 locking clips |
| Range compatibility | Acti 9 iTL auxiliary, Linergy Linergy FM, Acti 9 iOF+SD 24, Acti 9 iACT24, Acti 9 iATL24, PowerLogic pulse output meter, Acti 9 RCA iC60, Acti 9 Acti9 iCT auxiliary, Acti 9 Acti9 iC60, Acti 9 Acti9 iID, Acti 9 Acti9 iSW-NA, Acti 9 Acti9 iDPN Vigi, Acti 9 Acti9 C40, Multi9 Multi9 C60, Acti 9 Acti9 DT40, Acti 9 Acti9 DT60, Acti 9 Acti9 I-NA, Acti 9 Acti9 ITG40, Acti 9 Acti9 iDPN, Acti 9 Acti9 Reflex iC60 Ti24 connector |
| Commissioning interface | EcoStruxure Power Commission |
| Market segment | Buildings, Small commercial |
| Compatibility code | Acti 9 Smartlink |
| IP degree of protection | IP20 |
| IK degree of protection | IK06 conforming to IEC 62262 |
| Pollution degree | 3 |
| Electromagnetic compatibility | Resistance to electrostatic discharge (air discharge), class B, 8 kV, conforming to IEC 61000-4-2, Resistance to electrostatic discharge (contact discharge), class B, 4 kV, conforming to IEC 61000-4-2, Resistance to radiated electromagnetic fields (80 MHz...3 GHz), class A, 10 V/m, conforming to IEC 61000-4-3, Power supply: resistance to radiated electromagnetic fields (1.4…6 GHz), class A, 3 V/m, conforming to IEC 61000-4-3, Power supply: resistance to fast transient (5...100 kHz), class B, 2 kV, conforming to IEC 61000-4-4, Input/output: resistance to fast transient, class B, 1 kV, conforming to IEC 61000-4-4, Communication bus: resistance to fast transient (0.15...80 MHz), class B, 1 kV, conforming to IEC 61000-4-4, Conducted EMC (0.15...80 MHz), class A, 3 V, conforming to IEC 61000-4-6, Conducted emission (0.15...30 MHz), class B, conforming to IEC 61326-1, Conducted emission (0.15...30 MHz), class B, conforming to CISPR 11, Radiated emission (30...6000 MHz), class B, conforming to IEC 61326-1, Radiated emission (30...6000 MHz), class B, conforming to CISPR 11, Power supply: surges (DM coupling 42 Ohm), class B, 1 kV, conforming to IEC 61000-4-5, Power supply: surges (CM coupling 42 Ohm), class B, 2 kV, conforming to IEC 61000-4-5, Communication bus: surges (CM coupling 2 Ohm), class B, 1 kV, conforming to IEC 61000-4-5 |
| Environmental characteristic | Corrosive 3C2 conforming to IEC 60721-3-3, Salt mist 2 conforming to IEC 60068-2-52 |
| Vibration resistance | 1 gn, amplitude = 3.5 mm (f = 5…300 Hz)10 cycles conforming to EN/IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Fire resistance | Other parts: 650 °C ( 30 s ) conforming to IEC 60695-2-10, On connection terminals: 960 °C ( 30 s ) conforming to IEC 60695-2-10 |
| Tropicalisation | 2 |
| Relative humidity | 0…93 % at 40 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Standards | IEC 61010-2-201, IEC 61010-1 |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.300 cm |
| Package 1 Width | 6.500 cm |
| Package 1 Length | 37.000 cm |
| Package 1 Weight | 242.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 32 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 8.200 kg |
| Warranty (in months) | 18 |
More Schneider Electric parts
NewSchneider Electric LC1D80AKUE New open box

