Auxiliary contact, Acti9 A9A, iSD, 1 C/O, 2mA to 100mA, 24VAC to 250VAC, 24VDC to 220VDC, bottom connection
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Acti9 indication and tripping auxiliaries |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 32 kg |
Shipping & availability
When can A9A26917 be shipped?
A9A26917 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up A9A26917 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for A9A26917 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for A9A26917, subject to availability and destination.
This Acti9 electrical auxiliary is a modular fault contact used as remote indication of tripping upon a fault of the associated device to a programmable logic controller. The rated current (In) is from 2mA to 100mA with operating frequency of 50Hz to 60Hz at 24VAC to 250VAC, and from 2mA to 100mA at 24VDC to 220VDC. It has 1 position switch with contacts type 1 C/O. It is intended for new or renovated installation in small commercial, buildings, critical buildings, healthcare, industry, data center and infrastructures. This fault contact is compatible with Acti9 ranges such as iC60, iID, iDPN ARC, iDPN Vigi, iDPN Vigi ARC, iSW, iC40, iC40 ARC, iCV40, iC40 XA, iCV40 XA and iC60 RCBO. This fault contact is compatible with Acti9 ranges such as Acti9 iDT40, iDT40 XA, iDD40 and iKQE RCBO. It has a screw clamp terminal connection at bottom. The connection allows rigid copper cable. The cable cross section capacity is from 1mm² to 4mm². The iSD is either used for device short name or compatibility code. The mechanical indicator is provided on the product for signalling (Local). It has a screw clamp terminal connection at bottom. The connection allows rigid copper cable. The cable cross section capacity is from 1mm² to 4mm². It has a screw clamp terminal connection at bottom. The connection allows flexible copper cable. The cable cross section capacity is from 0.5mm² to 2.5mm². It has a screw clamp terminal connection at bottom. The connection allows rigid copper cables (2 cables). The cable cross section capacity is 2.5mm². It has a screw clamp terminal connection at bottom. The connection allows flexible with ferrule copper cables (2 cables). The cable cross section capacity is 1.5mm². The rated insulation voltage (Ui) is up to 500V. It has a rated impulse withstand voltage (Uimp) of 4kV. The width in 9mm pitches is 1. The dimensions are (W) 9mm x (H) 86mm x (D) 73mm. The product colour is white (RAL 9003). The pollution degree is 3. The level of tropicalisation is treatment 2. The tightening torque of connection is 1N.m (bottom) for PZ1 screwdriver type. According to IEC 60529 standard, the IP degree of protection is IP20. The operating temperature is from -25°C to +70°C. The storage temperature is from -40°C to +85°C. This product complies with EN/IEC 60947-5-1 and EN/IEC 60947-5-4 standards. This product is certified with CE and UKCA markings.
Specifications
Specifications
| range of product | Acti9 |
| Product or component type | Fault contact |
| Device short name | iSD |
| Signal contacts composition | 1 C/O |
| [In] rated current | 2…100 mA at 24...240 V, AC 50/60 Hz, 2…100 mA at 24 V, DC, 2…100 mA at 48 V, DC, 2…100 mA at 60 V, DC, 2…100 mA at 130 V, DC, 2…100 mA at 220 V, DC |
| 9 mm pitches | 1 |
| Standards | EN/IEC 60947-5-1, EN/IEC 60947-5-4, GB/T 14048.5, GB/T 14048.17 |
| Product certifications | CE, UKCA |
| Quality labels | EAC, CCC |
| Range compatibility | Acti9 iC60H RCBO, Acti9 iC60H RCBO PoN, Acti9 iC60H2 RCBO, Acti9 iC60N RCBO, Acti9 iKQE RCBO, Acti9 iCVm40, Acti9 iCVr40, Acti9 iDDm40 |
| Operating mode | Daisy chain up to 100 devices |
| [Ui] rated insulation voltage | 500 V |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Local signalling | Mechanical indicator |
| Mounting mode | Clip-on |
| Mounting location | Left side of circuit-breaker |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top: YES |
| Height | 86 mm |
| Width | 9 mm |
| Depth | 73 mm |
| Net weight | 32 g |
| Colour | White |
| Connections - terminals | Screw clamp terminal (bottom) 1 cable(s) 1…4 mm² - rigid, Screw clamp terminal (bottom) 1 cable(s) 0.5…2.5 mm² - flexible, Screw clamp terminal (bottom) 2 cable(s) 2.5 mm² - rigid, Screw clamp terminal (bottom) 2 cable(s) 1.5 mm² - flexible with ferrule |
| Wire stripping length | 10 mm |
| Tightening torque | 1 N.m bottom |
| IP degree of protection | IP20 |
| Pollution degree | 3 |
| Tropicalisation | 2 |
| Relative humidity | 95 % at 55 °C |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.200 cm |
| Package 1 Width | 8.000 cm |
| Package 1 Length | 9.300 cm |
| Package 1 Weight | 40.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 8.500 cm |
| Package 2 Width | 10.000 cm |
| Package 2 Length | 27.000 cm |
| Package 2 Weight | 562.000 g |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 120 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 6.257 kg |
| Warranty (in months) | 18 |