Schneider Electric 140AII33010

Intrinsically safe current input module Modicon Quantum

MPN
140AII33010
EAN
3595860025616
Price and lead time confirmed within 1 business day

Discontinued by Schneider Electric — we can still source the original 140AII33010 (new, used or refurbished, subject to availability). Request a quote below.

Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Schneider Electric parts? We buy surplus →

What is the Schneider Electric 140AII33010?

Schneider Electric 140AII33010 — intrinsically safe current input module Modicon Quantum. Discontinued by Schneider Electric. PartnerPLC sources discontinued and surplus Schneider Electric automation parts — request a quote for price, condition and lead time.

Specifications

Main

Range of productModicon Quantum automation platform
Product or component typeIntrinsically safe current input module
Software designationConcept version V2.2 and above; ProWORX; Unity Pro
Type of filterSingle low pass input filter -3 dB 15 Hz +/- 20 %

Complementary

Product destinationIn conjunction with products for zone 20, 21 or 22
Analogue input number8
Analogue input range0...20 mA; 0...25 mA; 4...20 mA
Analogue input resolution0...16000 counts 4...20 mA; 0...20000 counts 0...20 mA; 0...25000 counts 0...25 mA; 0...4095 counts 4...20 mA
Absolute maximum input25 mA internally limited
Input impedance100 Ohm +/- 0.1 %
Absolute accuracy error+/- 0.05 % typical of full scale at 25 °C; +/- 0.1 % of full scale maximum at 25 °C
Accuracy drift according to temperature+/- 0.0025 % typical of full scale/°C; 0.005 % maximum of full scale/°C
Linearity error0.003 % of full scale
Common mode rejection> 100 dB 50/60 Hz
Update time750 ms
Isolation between channels and bus2500 V for 1 minute DC; 1780 V 47...63 Hz AC
Fault typeBroken wire 4...20 mA
Power dissipation in W7.5 W
Hot swapping fallbackNot allowed per intrinsic safety standards
Protection typeInternal fuse
MarkingCE; II1 G/D-EEx ia IIC
Bus current requirement1500 mA
Module formatStandard
Net weight0.3 kg

Environment

StandardsDirective ATEX 94/9/EC; EN 50039; CSA C22.2 No 142; EN 50014; EN 50020; EN 50284; EN 50281-1-1; UL 508
Dust zoneOutside zone
Product certificationsGOST; C-Tick; FM Class 1 Division 2; SIRA 02ATEX2345X
Resistance to electrostatic discharge4 kV contact conforming to IEC 801-2; 8 kV on air conforming to IEC 801-2
Resistance to electromagnetic fields10 V/m 80…2000 MHz conforming to IEC 801-3
Ambient air temperature for operation0…60 °C
Ambient air temperature for storage-40…85 °C
Relative humidity95 % without condensation
Operating altitude<= 5000 m

Downloads & documentation

Official documents from Schneider Electric, downloaded directly from the manufacturer.

Data sheets & manuals

140AII33010: frequently asked questions

Can I still buy the 140AII33010 now that it is discontinued?

Yes. Schneider Electric has discontinued the 140AII33010, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.

When can 140AII33010 be shipped?

140AII33010 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 140AII33010 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 140AII33010 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 140AII33010, subject to availability and destination.

More Schneider Electric parts

Schneider Electric 140ACO13000 – Analog output module Modicon Quantum - 8 O multirange
Schneider Electric
140ACO13000

Analog output module Modicon Quantum - 8 O multirange

Schneider Electric 140ACO13000C – Analog output module Modicon Quantum - 8 O
Schneider Electric
140ACO13000C

Analog output module Modicon Quantum - 8 O

Schneider Electric 140AII33000 – Intrinsically safe temperature input module Modicon Quantum - 8 I
Schneider Electric
140AII33000

Intrinsically safe temperature input module Modicon Quantum - 8 I

Schneider Electric 140AII33000C – Intrinsically safe temperature input module - Modicon Quantum - 8 I
Schneider Electric
140AII33000C

Intrinsically safe temperature input module - Modicon Quantum - 8 I

Schneider Electric 140AII33010C – Modicon Quantum intrinsically safe current input module - 8 I
Schneider Electric
140AII33010C

Modicon Quantum intrinsically safe current input module - 8 I

Schneider Electric 140AIO33000 – Intrinsically safe analog output module Modicon Quantum - 8 O
Schneider Electric
140AIO33000

Intrinsically safe analog output module Modicon Quantum - 8 O

Schneider Electric 140AIO33000C – Intrinsically safe analog output module - Modicon Quantum - 8 O
Schneider Electric
140AIO33000C

Intrinsically safe analog output module - Modicon Quantum - 8 O

Schneider Electric 140AMM09000 – Analog input output module Modicon Quantum - 4 I - 2 O
Schneider Electric
140AMM09000

Analog input output module Modicon Quantum - 4 I - 2 O

Schneider Electric 140AII33010Price and lead time confirmed within 1 business day
Request a Quote