Pepperl Fuchs VAZ-2E2A-G20-ZPA1

ZPA Motor Roller Module

MPN
VAZ-2E2A-G20-ZPA1
Category
Modules
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Pepperl Fuchs parts? We buy surplus →

What is the Pepperl Fuchs VAZ-2E2A-G20-ZPA1?

Inputs for 3-wire sensors

Outputs for DC roller motors (drum motors)

Interface for coupling with adjacent zones

Connection of motors and sensors via M8 connectors

Operating mode, motor speed and start/stop ramp can be configured using the rotary switch

Supply of 24 VDC, connection via insulation piercing technology with gold-plated contact pins

Function indicator for power supply, inputs and outputs, and zone coupling

Stand-alone G20 MDR module with integrated ZPA logic for 2 digital inputs and 2 connections for MDRs

Specifications

General specifications

Order code (Pepperl+Fuchs part number)70130651
UL File NumberE223772 "For use in NFPA 79 Applications only"
Compatible roller motorsInterroll EC310 Interroll EC5000 24 V AI (20 W / 35 W / 50 W) Rulmeca BL3 Itoh Denki PM500XK Itoh Denki PM500XC PULSEROLLER Senergy-IDC MTA MRD50 (A interface, 24 V to 40 W) WWL R-*-H + CE23XX Conveline RM50 Mambaroll Built-In Drive Roller 50 UniDrive ONE
LifecycleActive (current Pepperl+Fuchs product)

Indicators/operating means

SwitchS1: motor speed; rotary switch, 10 positions S2: direction of rotation and start/stop ramp; rotary switch, 10 positions S3: operating mode, rotary switch, 10 positions
LED ERRMotor fault; 2 yellow LEDs yellow: motor error flashing yellow: motor protection unit defective
LED PWRSupply voltage UPWR; green LED
LED INswitching state (input); 2 LED yellow
LED MOTMotor active; 2 yellow LEDs
LED XINZone coupling input active; 2 yellow LEDs
LED XOUTZone coupling output active; 2 yellow LEDs

Electrical specifications

Rated operating voltage18 V ... 30 V DC PELV (via UPWR) Ue
Rated operating current≤ 30 mA (Closed-circuit current) max. 10 A (<2 s) Ie
Surge protectionUPWR: overvoltage category II, securely isolated power supply (PELV)

Interface 1

Interface typeInterface for coupling zones with one input and one output for control signals X1
Physical4-pin M12 socket Electronic output: PNP, overload and short-circuit proof (X1OUT) Input: PNP, galvanically isolated, potential-free (X1IN)
Load currentInput: ≤ 8 mA (internally limited) Output: 10 mA
VoltageInput: max. 30 V DCOutput (via UPWR): ≥ (UPWR - 2 V)
Switching pointin accordance with DIN EN 61131-2 (type 1) 0 (undamped): ≤ 0.5 mA 1 (damped): ≥ 2 mA

Interface 2

Interface typeInterface for coupling zones with one input and one output for control signals X2
PhysicalM12 connector, 4-pin Electronic output: PNP, overload and short-circuit proof (X2OUT) Input: PNP, galvanically isolated, potential-free (X2IN)
Load currentInput: ≤ 8 mA (internally limited) Output: 10 mA
VoltageInput: max. 30 V DCOutput (via UPWR): ≥ (UPWR - 2 V)
Switching pointin accordance with DIN EN 61131-2 (type 1) 0 (undamped): ≤ 0.5 mA 1 (damped): ≥ 2 mA

Input

Number/Type2 Inputs for 3-wire sensors (PNP), DC
Supplyvia UPWR
Current loading capacity500 mA , overload and short-circuit protected
Input current≤ 8 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 0 (undamped) ≤ 0.5 mA 1 (damped) ≥ 2.0 mA
Input filter10 ms

Output

Number/Type2 outputs for DC roller motors (MOT1, MOT2)
Supplyvia UPWR
Current3.5 A continuous current , 5 A (<2 s) , max. 7.5 A (<0,3 s) per motor
Overload protectionFuse 5 A, I2t = 53.7 A2s per motor
Velocity signal1.4 … 13 V at no-load Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ Control using rotary switch S1 US
Rotation direction signallow: high impedance high; ≥ (UPWR - 1.0 V) in no-load operation Ri = 5.6 kΩ, RLOAD ≥ 5 kΩ Control using rotary switch S2 UD
Motor faultNPN digital input, U0 = 14 V, Ri = 34 kΩ 0 (no error) ≥ 125 µA 1 (error) ≤ 25 µA

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2006

Standard conformity

Degree of protectionEN 60529:2000
InputEN 61131-2:2007
Emitted interferenceEN 61000-6-4:2007
Noise immunityEN 61000-6-2:2005 , EN 61326-1:2006

Ambient conditions

Ambient temperature-30 ... 60 °C (-22 ... 140 °F)
Storage temperature-30 ... 85 °C (-22 ... 185 °F)
Relative humidity85 % non-condensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions,1000 shocks
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Pollution degree2

Mechanical specifications

Degree of protectionIP67 according to EN 60529
ConnectionPWR: insulation piercing technology Black flat cable Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104 Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded)Matching connector: LM004-Gx1-A or similar Outputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded) Matching connector: NM005-Sx1-B or similar Zone coupling: M12 round plug connector in accordance with EN 61076-2-101 X1: M12, 4-pin, bushing contacts, screw-locking, A-coded Female connector: M12, 4-pin, connector contacts, screw-locking, A-coded X2: M12, 4-pin, connector contacts, screw-locking, A-coded Female connector: M12, 4-pin, bushing contacts, screw-locking, A-coded
Mass310 g
Dimensions: Height27.5 mm
Dimensions: Width131.5 mm
Dimensions: Length54 mm
Mounting2 clips with ∅ 8 mm drill hole
Cable length1 m (inputs/outputs) , 1.5 m (zone coupling), max. 30 m
NoteThe flat cable routing is designed for 100 actuation cycles

VAZ-2E2A-G20-ZPA1: frequently asked questions

When can VAZ-2E2A-G20-ZPA1 be shipped?

VAZ-2E2A-G20-ZPA1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up VAZ-2E2A-G20-ZPA1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for VAZ-2E2A-G20-ZPA1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VAZ-2E2A-G20-ZPA1, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs VAS-4A16L-K31 – AS-Interface Safety Monitor
Pepperl Fuchs
VAS-4A16L-K31

AS-Interface Safety Monitor

Pepperl Fuchs VAZ-2E2A-G20-ZPA1Price and lead time confirmed within 1 business day
Request a Quote