What is the Pepperl Fuchs SLCS30/35?
Resolution 30 mm (hand protection)
Protection field height up to 2400 mm
Self-monitoring (type 4 according to IEC/EN 61496-1)
SIL3 (IEC 61508)
Sensing range up to 20 m
Degree of protection IP67
Temperature range -35 ... 60°C (-31 ... 140 °F)
Slim design, mounting on three sides
Resolution 30 mm (hand protection), Protection field height up to 2400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), SIL3 (IEC 61508), Sensing range up to 20 m, Degree of protection IP67, Temperature range -35 ... 60°C (-31 ... 140 °F), Slim design, mounting on three sides, Protection field height: see Table 1, max. 2400 mm, Operating mode: Startup/restart disable, deactivateable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 265788 |
| Effective detection range | 5 ... 20 m |
| Light source | IRED |
| Light type | modulated infrared light , 850 nm |
| Protection field height | see Table 1, max. 2400 mm |
| Operating mode | Startup/restart disable, deactivateable |
| Optical resolution | 30 mm |
| Opening angle | < 5 ° |
| Ambient light limit | Not sensitive to ambient light in accordance with IEC 61496-2 |
| UL File Number | E215245 |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
| Performance level (PL) | PL e |
| Category | Cat. 4 |
| Mission Time (TM) | 20 a |
| PFHd | Depending on the protection field height; see Manual |
| Type | 4 |
Indicators/operating means
| Operation indicator | green: Power on |
| Function indicator | Green: OSSD ON , Red: OSSD OFF |
| Status indicator | Transmitter unit: LED yellow: Mode, test or error Receiver: LED yellow: Start readiness, operating reserve, or error |
Electrical specifications
| Operating voltage | 24 V DC (-20%, +30%) ; Power supply with safe isolation: 24 V DC UB |
| No-load supply current | Transmitter unit:≤ 150 mA Receiver: ≤ 150 mA (without outputs) I0 |
| Protection class | III , IEC 61140 |
| Power consumption | Transmitter unit: 5 W Receiver: 15 W P0 |
Input 1
| Input type | Transmitter unit test |
| Input format | Break contact |
| Switching voltage | 24 V DC |
| Input current | 5 mA |
Input 2
| Input type | Transmitter unit, mode A/B |
| Function | Beam Code A: open or 0 VBeam Code B: 24 V DC, 5 mA |
Input 3
| Input type | Receiver unit relay monitor |
| Input format | Break contact |
| Switching voltage | 24 V DC |
| Input current | 5 mA |
Input 4
| Input type | Receiver unit, start release |
| Input format | Break contact |
| Input current | 5 mA |
Input 5
| Input type | Receiver unit, mode A/B (see transmitter unit, mode A/B) |
Output
| Response time | see Table 1, max. 48 ms |
Output 1
| Output type | Receiver unit OSSD |
| Signal output | PNP semiconductor , monitored for short and cross circuits |
| Switching voltage | ON: UB - 2 V; OFF: < 1 V |
| Switching current | ON: max. 0.1 A; OFF: < 5 µA |
Output 2
| Output type | Receiver signal output start readiness |
| Signal output | PNP-semiconductor, short-circuit protected, 0.1A |
Conformity
| Functional safety | ISO 13849-1 ; EN 61508 part1-4 |
| Product standard | EN 61496-1 ; IEC 61496-2 |
| Photobiological safety | Risk group 0 according to IEC 62471 |
Approvals and certificates
| CE conformity | CE |
| UKCA conformity | UKCA |
| UL approval | cULus Listed |
| TÜV approval | TÜV SÜD |
Ambient conditions
| Ambient temperature | -35 ... 60 °C (-31 ... 140 °F) |
| Storage temperature | -35 ... 70 °C (-31 ... 158 °F) |
| Relative humidity | max. 95 %, non-condensing |
| Shock resistance | 10 g , 16 ms ; stationary applications only |
| Vibration resistance | 0.35 mm , 10 ... 55 Hz ; stationary applications only |
Mechanical specifications
| Housing length L | see table 2 |
| Degree of protection | IP67 , For indoor use only |
| Connection | Transmitter unit: 4-pin, M12 x 1 connector Receiver: 8-pin, M12 x 1 connector Cable cross section min. 0.25 mm2 Max. cable length 50 m |
| Material: Housing | extruded aluminum section , gold anodized |
| Material: Optical face | Plastic pane , Transparent polycarbonate |
| Mass | see table 2 |
| Dimensions: Width | 20 mm |
| Dimensions: Depth | 30 mm |
General information
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
- 3-D model (STEP) SLCS30/35
- 3-D model (STEP) SLCS30/35
- 3-D model (STEP) SLCS30/35
- 3-D model (STEP) SLCS30/35
- 3-D model (STEP) SLCS30/35
- 3-D model (STEP) SLCS30/35
- 3-D model (STEP) SLCS30/35
- 3-D model (STEP) SLCS30/35
- 3-D model (STEP) SLCS30/35
- 3-D model (STEP) SLCS30/35
- 3-D model (STEP) SLCS30/35
- 3-D model (STEP) SLCS30/35
SLCS30/35: frequently asked questions
When can SLCS30/35 be shipped?
SLCS30/35 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SLCS30/35 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SLCS30/35 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SLCS30/35, subject to availability and destination.