Pepperl Fuchs SC-GPCS-UNI16-PF
Termination Board
- MPN
- SC-GPCS-UNI16-PF
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- Ships via
- 100% positive eBay feedback
What is the Pepperl Fuchs SC-GPCS-UNI16-PF?
System board for Honeywell Experion PKS, Series C
For 16-channel AI card CC-TAIX01/11
For 16-channel AO card CC-TAOX01/11
For 32-channel DI card CC-TDIL01/11
For 32-channel DO card CC-TDOB01/11
For 16 modules
Recommended modules: HiC2025(A) (AI), HiC2031 (AO), HiC2821 (DI), HiC2871 (DO)
Recommended system cable: CAB-HON-**-S37C32-MX-01000
24 V DC supply
Hazardous area: pluggable screw terminals, blue
Non-hazardous area: Sub-D connector (male), 37-pin
System board for Honeywell Experion PKS, Series C, For 16-channel AI card CC-TAIX01/11, For 16-channel AO card CC-TAOX01/11, For 32-channel DI card CC-TDIL01/11, For 32-channel DO card CC-TDOB01/11, For 16 modules, Recommended modules: HiC2025(A) (AI), HiC2031 (AO), HiC2821 (DI), HiC2871 (DO), Recommended system cable: CAB-HON-**-S37C32-MX-01000, 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Number of modules: 16, Signal type: Universal, Manufacturer: Honeywell
Specifications
Supply
| Order code (Pepperl+Fuchs part number) | 209365 |
| Connection | TB3: terminals 2, 4(+); 1, 3(-) |
| Nominal voltage | 24 V DC , in consideration of rated voltage of used isolators |
| Voltage drop | 0.9 V , voltage drop across the series diode on the termination board must be considered |
| Ripple | ≤ 10 % |
| Fusing | 4 A , in each case for 16 modules |
| Power dissipation | ≤ 500 mW , without modules |
| Reverse polarity protection | yes |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Redundancy
| Supply | Redundancy available. The supply for the isolators is decoupled, monitored and fused. |
Fault indication output
| Connection | TB4: terminals 1, 2 |
| Output type | volt-free contact |
| Switch behaviour | no fault: relay contact closed power supply fault: relay contact open module fault: relay contact open |
| Contact loading | 30 V DC , 1 A |
Indicators/settings
| Display elements | LED Supply1 (power supply termination board), green LED LED Supply2 (power supply termination board), green LED LED Fault Status (fault indication), green LED - LED lits: no module fault/no power supply fault |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2017 For further information see system description. |
| Degree of protection | IEC 60529:2001 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection: Field side | explosion hazardous area: pluggable screw terminals , blue |
| Connection: Control side | non-explosion hazardous area: 37-pin Sub-D connector |
| Connection: Supply | pluggable screw terminals , black |
| Connection: Fault output | pluggable screw terminals , black |
| Core cross section | screw terminals: 0.25 ... 2.5 mm2 (24 ... 12 AWG) |
| Material | housing: polycarbonate |
| Mass | approx. 825 g |
| Dimensions | 273 x 155 x 153 mm (10.7 x 6.1 x 6.0 inch) (W x H x D) , depth including module assembly |
| Height | 155 mm |
| Width | 273 mm |
| Depth | 153 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | CESI 06 ATEX 022 |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Non-hazardous area: Maximum safe voltage | 250 V (Attention! Um is no rated voltage.) |
| Certificate | DEMKO 18 ATEX 2116 X |
| Marking | II 3G Ex ec nC IIC T4 Gc |
| Galvanic isolation: Field circuit/control circuit | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-15:2010 , EN 50303:2000 |
International approvals
| UL approval | E106378 |
| Control drawing | 116-0327 |
| IECEx approval: IECEx certificate | IECEx CES 06.0003 IECEx UL 18.0111 X |
| IECEx approval: IECEx marking | [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I Ex ec nC IIC T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
Certificates (6)
- EU Declaration of Conformity (Pepperl+Fuchs)
- South Africa MASC (MASC MS/17-0855)
- Brasil TUV Rheinland Brazil (TÜV 14.0084 X)
- Europe CESI ATEX Category (1) GD ATEX Category (M1) (CESI 06 ATEX 022)
- Canada USA UL Certificate of Compliance Hazardous Location UL E106378 cULus (CoC E106378 RepRef E106378-20100930)
- Europe DEMKO ATEX Category 3 G (DEMKO 18 ATEX 2116X)
SC-GPCS-UNI16-PF: frequently asked questions
When can SC-GPCS-UNI16-PF be shipped?
SC-GPCS-UNI16-PF is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SC-GPCS-UNI16-PF in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SC-GPCS-UNI16-PF and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SC-GPCS-UNI16-PF, subject to availability and destination.
More Pepperl Fuchs parts