What is the Pepperl Fuchs NCN3-F31K-N4-B13?

Direct mounting on standard actuators

Fixed setting

Cage clamp terminals

Usable up to SIL 2 acc. to IEC 61508

LEDs for switching state of sensor and solenoid valve

Valve LEDs disconnectable

ATEX & IECEX certifications

Extended temperature range, Valve position detection, Solenoid valve output, Suitable for 2:1 technology, Switching function: 2 x normally closed (NC), Output type: NAMUR, Installation: flush mountable, Output type: 2-wire, Construction type: Dual sensor, Series: Dual sensor, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx TUN 17.0021X, Equipment protection level Gb: IECEx TUN 17.0021X

Specifications

General specifications

Order code (Pepperl+Fuchs part number)70110340
Switching function2 x normally closed (NC)
Output typeNAMUR
Rated operating distance3 mm sn
Installationflush mountable
Assured operating distance0 ... 2.4 mm sa
Actual operating distance2.7 ... 3.3 mm typ. sr
Actuating elementStainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm
Reduction factor rAl0.5
Reduction factor rCu0.4
Reduction factor r3041
Reduction factor rSt371.3
Reduction factor rBrass0.6
Output type2-wire
LifecycleActive (current Pepperl+Fuchs product)

Nominal ratings

Nominal voltage8.2 V (Ri approx. 1 kΩ) Uo
Switching frequency0 ... 3 kHz f
Hysteresistyp. 5 % H
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption: Measuring plate not detected≥ 3 mA
Current consumption: Measuring plate detected≤ 1 mA
Time delay before availability≤ 1.1 ms tv
Switching state indicatorLED, yellow
Valve status indicatorLED, yellow

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2
MTTFd1470 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %

Valve circuit

Voltagemax. 32 V DC
Currentmax. 240 mA
Short-circuit protectionno
Reverse polarity protectionyes, with reversed output LED is out of function, therfore more power for solenoid valve

Compliance with standards and directives

Standard conformity: NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
Standard conformity: Electromagnetic compatibilityNE 21:2007
Standard conformity: StandardsEN IEC 60947-5-2

Approvals and certificates

IECEx approval: Equipment protection level GaIECEx TUN 17.0021X
IECEx approval: Equipment protection level GbIECEx TUN 17.0021X
IECEx approval: Equipment protection level MbIECEx TUN 17.0021X
ATEX approval: Equipment protection level GaTÜV 99 ATEX 1479 X
ATEX approval: Equipment protection level GbTÜV 99 ATEX 1479 X
ATEX approval: Equipment protection level Gc (ic)PF 13 CERT 2895 X
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0456
CCC approval: Hazardous Location2020322315002262
NEPSI approval: NEPSI certificateGYJ19.1410X

Ambient conditions

Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)

Mechanical specifications

Connection (system side)Cage tension spring terminals Stripped length 7 mm M20 x 1.5 cable gland usable thread length 11.5 mm screw-in depth max. 11.5 mm
Core cross section (system side)rigid: 0.14 ... 2.5 mm2 flexible: 0.14 ... 1.5 mm2 flexible with core-end sleeve: 0.25 ... 1.5 mm2
Connection (valve side)like connection (system side)
Core cross section (valve side)like core cross section (system side)
Housing materialPBT
Sensing facePBT
Degree of protectionIP67
Tightening torque, fastening screws≤ 5 Nm
Tightening torque, housing screws1 Nm
Tightening torque, cable glandM20 x 1.5 ; max. 7 Nm
Dimensions: Height35.5 mm
Dimensions: Width65 mm
Dimensions: Length77.5 mm
NoteLED switch-off

General information

Use in the hazardous areasee instruction manuals

NCN3-F31K-N4-B13: frequently asked questions

When can NCN3-F31K-N4-B13 be shipped?

NCN3-F31K-N4-B13 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up NCN3-F31K-N4-B13 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for NCN3-F31K-N4-B13 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NCN3-F31K-N4-B13, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs NCN3-F31K-N4-B13Price and lead time confirmed within 1 business day
Request a Quote