Quick facts

AvailabilityConfirmed on request
CategoryVibration Limit Switches
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can LVL-M4-A be shipped?

LVL-M4-A is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up LVL-M4-A in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for LVL-M4-A and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LVL-M4-A, subject to availability and destination.

Vibration Limit Switch Compact Version. Vibration limit switch for liquids , Compact device, Wide variety of electronic modules (e. g., relay, thyristor signal output): the right connection for every process control system, No calibration: quick and low-cost start up, No mechanically moving parts: maintenance-free, no wear, long operating life, Operation via push buttons and DIP switches on the electronic insert, Optional status and fault indication via LED module or via Bluetooth in the P+F Level app, Up to SIL 3 acc. to IEC/EN 61508. Function principle: point level detection, maximum or minimum detection for liquids. Measuring method: The change in vibration frequency causes the device to switch.. Construction type: compact device. Series: Vibracon LVL-M4. Housing: single compartment, aluminum, coated single compartment, 316L, cast single compartment, plastic dual compartment, L-shape, aluminum, coated. Safety Integrity Level (SIL): SIL 3. Rated voltage: electronic insert FEL61: 19 ... 253 V AC, 50/60 Hz electronic insert FEL62: 10 V DC ... 55 V DC electronic insert FEL64: 19 V AC ... 253 V AC50/60 Hz / 19 V DC ... 55 V DC electronic insert FEL64DC: 9 V DC ... 20 V DC electronic insert FEL68: switch amplifier acc. to IEC 60947-5-6 (NAMUR). Current consumption: electronic insert FEL61: ≤ 3.8 mA electronic insert FEL62: ≤ 10 mA, without load. Power consumption: electronic insert FEL61: ≤ 2 VA electronic insert FEL62: ≤ 0.5 W electronic insert FEL64: ≤ 25 VA/< 1.3 W electronic insert FEL64DC: < 1.0 W electronic insert FEL68: acc. to IEC 60947-5-6 (NAMUR). Interface type: Bluetooth® , optional. Detection range: max. 25 m. Configuration: commissioning, operation and maintenance via P+F Level app - can be activated/deactivated - password encryption. Communication: encrypted. Switching point: see section switch point. Measured variable: limit level (limit value). Measuring range: depends on installation location and the tube extension maxmum sensor length : 6 m. Output type: electronic insert FEL61: 2-wire with test button electronic insert FEL62: 3-wire PNP with test button electronic insert FEL64: relay DPDT with test button electronic insert FEL64DC: relay DPDT with contact and test button electronic insert FEL68: 2-wire NAMUR with test button. Switch behaviour: switch-over for minimum/maximum residual current safety on electronic insertMAX = maximum safety:The output switches to the power fail response when the fork is covered.for use with overspill protection for exampleMIN = minimum safety:The output switches to the power fail response when the fork is exposed.for use with dry running protection for example. Communication: connection for LED module VU120 and Bluetooth module VU121 , optional Bluetooth wireless technology , optional. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326: . Directive 2014/30/EU: EN 61326. Low voltage: . Directive 2014/35/EUEN 61010-1: . Directive 2014/35/EU: EN 61010-1. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529 , NEMA 250. Shock resistance: IEC 60068-2-27. Vibration resistance: EN 60068-2-64. Climate class: IEC 60068-2-38 test Z/AD. Corrosion resistance: acc. to ISA-71.04, severity level G3. Medium density: adjustment on the electronic insert > 0,5 g/cm3 or > 0,7 g/cm3 (other on request). Reference operating conditions: ambient temperature: 23 °C (73 °F)process temperature: 23 °C (73 °F)density: 1 g/cm3 (water)medium viscosity: 1 mPa·sprocess pressure: ambietn pressure/unpressurizedsensor installation: verticaly from abovedensity selection switch: > 0.7 g/cm3switch direction of sensor: uncovered to covered. Maximum measured error: max. ± 1 mm. Hysteresis: typ. 2.5 mm. Influence of medium density: see technical information (TI). Influence of medium temperature: max. +1.4 ... -2.6 mm (-50 ... 150 °C (-58 ... 302 °F)). Influence of medium pressure: max. 0 ... 2.6 mm (-1 ... 64 bar). Installation conditions: . Installation positionany position: . Installation position: any position. Process conditions: . Medium temperature-50 ... 150 °C (-58 ... 302 °F)Medium pressurepe = 0 ... 100 bar (0 ... 1450.4 psi) over the entire temperature range , exceptions see process connectionsTest pressurePN = 64 bar (928 psi): test pressure = 1.5 x PN maximum 100 bar (1450 psi) depending on process connection selected PN = 100 bar (1450 psi): test pressure = 1.5 x PN maximum 150 bar (2175 psi) depending on process connection selectedThermal shock resistance≤ 120 K/sState of aggregationliquidDensitymin. 0.5 g/cm3 , optional 0.4 g/cm3Viscositymax. 10000 mm2/s (max. 10000 cSt): . Medium temperature: -50 ... 150 °C (-58 ... 302 °F). Medium pressure: pe = 0 ... 100 bar (0 ... 1450.4 psi) over the entire temperature range , exceptions see process connections. Test pressure: PN = 64 bar (928 psi): test pressure = 1.5 x PN maximum 100 bar (1450 psi) depending on process connection selected PN = 100 bar (1450 psi): test pressure = 1.5 x PN maximum 150 bar (2175 psi) depending on process connection selected. Thermal shock resistance: ≤ 120 K/s. State of aggregation: liquid. Density: min. 0.5 g/cm3 , optional 0.4 g/cm3. Viscosity: max. 10000 mm2/s (max. 10000 cSt). Ambient temperature: -60 ... 70 °C (-76 ... 158 °F) For further information see technical information (TI).. Storage temperature: -40 ... 80 °C (-40 ... 176 °F). Altitude: ≤ 2000 m above MSL. Degree of protection: plug M12 : IP66/67, NEMA type 4X Others : IP66/68, NEMA type 4X/6P. Connection: gland M20 thread M20 , G1/2 , NPT1/2 , NPT3/4 plug M12. Material: see technical information (TI). Surface quality: Ra < 3.2 µm/126 µinch. Mass: basic weight: 0.65 kgthe basic weight comprises:- sensor (compact)- electronic insert- housing: single compartment, plastic with cover- process connection: thread, G3/4in addition to the basic weight:- modules: 0,1 kg- housing: single compartment, aluminum, coated: 0.8 kg, single compartment, 316L: 1.21 kg, dual compartment, L-shaped, aluminum, coated: 1.22 kg - temperature spacer: 0.6 kg- pressure-tight feed through: 0.7 kg- pipe extension: 1000 mm: 0.9 kg, 100 inch: 2.3 kg- plastic protective cover: 0.2 kg For further information see technical information (TI).. Dimensions: housing: diameter max. 147 mm, heigth max. 163 mm temperature spacer, pressure-tight feed through: additional length 140 mm compact version: length depends on process connection short tube version: length 99 ... 118 mm, depends on process connection pipe extension:- length 117 ... 6000 mm, 316L- length 148 ... 3000 mm, Alloy C22 tuning fork: width 17.2 mm, fork width 10 mm, length 40 mm For further information see technical information (TI).. Process connection: cylindrical threads G3/4, G1 acc. to DIN ISO 228 G for installing in weld-in adapter cylindrical threads G3/4, G1 acc. to DIN ISO 228 G with flat seal conical threads NPT3/4, NPT1 acc. to ANSI B 1.20.3 conical threads R3/4, R1 acc. to EN 10226 flanges RF, RJF, FF from 1 inch acc. to ASME B16.5 flanges form A, B1, C, D, E from DN25 acc. to EN 1092-1 flanges RF from 10K 25A acc. to JIS B2220 Tri-Clamp from DN25 acc. to ISO 2852 For further information see technical information (TI).. EU-type examination certificate: see instruction manuals. CSA approval: see instruction manuals. IECEx approval: see instruction manuals. Display elements: Standard: without display LED module VU120, optional Bluetooth module VU121, optional. Control elements: switches on the electronic insert. Function test: via switches on the electronic insert test magnet , optional. Overspill protection: see approval (ZE). Supplementary documentation: technical information (TI) manuals, brief instructions (BA, KA) instruction manuals Functional safety manuals (FY) Special documentation (SD). Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.. Designation: see technical information (TI)

Specifications

General specifications

Function principlepoint level detection, maximum or minimum detection for liquids
Measuring methodThe change in vibration frequency causes the device to switch.
Construction typecompact device
SeriesVibracon LVL-M4
Housingsingle compartment, aluminum, coated single compartment, 316L, cast single compartment, plastic dual compartment, L-shape, aluminum, coated

Functional safety related parameters

Safety Integrity Level (SIL)SIL 3

Supply

Rated voltageelectronic insert FEL61: 19 ... 253 V AC, 50/60 Hz electronic insert FEL62: 10 V DC ... 55 V DC electronic insert FEL64: 19 V AC ... 253 V AC50/60 Hz / 19 V DC ... 55 V DC electronic insert FEL64DC: 9 V DC ... 20 V DC electronic insert FEL68: switch amplifier acc. to IEC 60947-5-6 (NAMUR) Ur
Current consumptionelectronic insert FEL61: ≤ 3.8 mA electronic insert FEL62: ≤ 10 mA, without load
Power consumptionelectronic insert FEL61: ≤ 2 VA electronic insert FEL62: ≤ 0.5 W electronic insert FEL64: ≤ 25 VA/< 1.3 W electronic insert FEL64DC: < 1.0 W electronic insert FEL68: acc. to IEC 60947-5-6 (NAMUR)

Interface

Interface typeBluetooth® , optional
Detection rangemax. 25 m
Configurationcommissioning, operation and maintenance via P+F Level app - can be activated/deactivated - password encryption
Communicationencrypted

Input

Switching pointsee section switch point
Measured variablelimit level (limit value)
Measuring rangedepends on installation location and the tube extension maxmum sensor length : 6 m

Output

Output typeelectronic insert FEL61: 2-wire with test button electronic insert FEL62: 3-wire PNP with test button electronic insert FEL64: relay DPDT with test button electronic insert FEL64DC: relay DPDT with contact and test button electronic insert FEL68: 2-wire NAMUR with test button
Switch behaviourswitch-over for minimum/maximum residual current safety on electronic insertMAX = maximum safety:The output switches to the power fail response when the fork is covered.for use with overspill protection for exampleMIN = minimum safety:The output switches to the power fail response when the fork is exposed.for use with dry running protection for example
Communicationconnection for LED module VU120 and Bluetooth module VU121 , optional Bluetooth wireless technology , optional

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326 Directive 2014/30/EU
Directive 2014/30/EUEN 61326
Low voltage
Directive 2014/35/EUEN 61010-1 Directive 2014/35/EU
Directive 2014/35/EUEN 61010-1

Conformity

Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529 , NEMA 250
Shock resistanceIEC 60068-2-27
Vibration resistanceEN 60068-2-64
Climate classIEC 60068-2-38 test Z/AD
Corrosion resistanceacc. to ISA-71.04, severity level G3

Input characteristics

Medium densityadjustment on the electronic insert > 0,5 g/cm3 or > 0,7 g/cm3 (other on request)

Measurement accuracy

Reference operating conditionsambient temperature: 23 °C (73 °F)process temperature: 23 °C (73 °F)density: 1 g/cm3 (water)medium viscosity: 1 mPa·sprocess pressure: ambietn pressure/unpressurizedsensor installation: verticaly from abovedensity selection switch: > 0.7 g/cm3switch direction of sensor: uncovered to covered
Maximum measured errormax. ± 1 mm
Hysteresistyp. 2.5 mm
Influence of medium densitysee technical information (TI)
Influence of medium temperaturemax. +1.4 ... -2.6 mm (-50 ... 150 °C (-58 ... 302 °F))
Influence of medium pressuremax. 0 ... 2.6 mm (-1 ... 64 bar)

Operating conditions

Installation conditions
Installation positionany position Installation position
Installation positionany position
Process conditions
Medium temperature-50 ... 150 °C (-58 ... 302 °F)Medium pressurepe = 0 ... 100 bar (0 ... 1450.4 psi) over the entire temperature range , exceptions see process connectionsTest pressurePN = 64 bar (928 psi): test pressure = 1.5 x PN maximum 100 bar (1450 psi) depending on process connection selected PN = 100 bar (1450 psi): test pressure = 1.5 x PN maximum 150 bar (2175 psi) depending on process connection selectedThermal shock resistance≤ 120 K/sState of aggregationliquidDensitymin. 0.5 g/cm3 , optional 0.4 g/cm3Viscositymax. 10000 mm2/s (max. 10000 cSt) Medium temperature
Medium temperature-50 ... 150 °C (-58 ... 302 °F)
Medium pressurepe = 0 ... 100 bar (0 ... 1450.4 psi) over the entire temperature range , exceptions see process connections
Test pressurePN = 64 bar (928 psi): test pressure = 1.5 x PN maximum 100 bar (1450 psi) depending on process connection selected PN = 100 bar (1450 psi): test pressure = 1.5 x PN maximum 150 bar (2175 psi) depending on process connection selected
Thermal shock resistance≤ 120 K/s
State of aggregationliquid
Densitymin. 0.5 g/cm3 , optional 0.4 g/cm3
Viscositymax. 10000 mm2/s (max. 10000 cSt)

Ambient conditions

Ambient temperature-60 ... 70 °C (-76 ... 158 °F) For further information see technical information (TI).
Storage temperature-40 ... 80 °C (-40 ... 176 °F)
Altitude≤ 2000 m above MSL

Mechanical specifications

Degree of protectionplug M12 : IP66/67, NEMA type 4X Others : IP66/68, NEMA type 4X/6P
Connectiongland M20 thread M20 , G1/2 , NPT1/2 , NPT3/4 plug M12
Materialsee technical information (TI)
Surface qualityRa < 3.2 µm/126 µinch
Massbasic weight: 0.65 kgthe basic weight comprises:- sensor (compact)- electronic insert- housing: single compartment, plastic with cover- process connection: thread, G3/4in addition to the basic weight:- modules: 0,1 kg- housing: single compartment, aluminum, coated: 0.8 kg, single compartment, 316L: 1.21 kg, dual compartment, L-shaped, aluminum, coated: 1.22 kg - temperature spacer: 0.6 kg- pressure-tight feed through: 0.7 kg- pipe extension: 1000 mm: 0.9 kg, 100 inch: 2.3 kg- plastic protective cover: 0.2 kg For further information see technical information (TI).
Dimensionshousing: diameter max. 147 mm, heigth max. 163 mm temperature spacer, pressure-tight feed through: additional length 140 mm compact version: length depends on process connection short tube version: length 99 ... 118 mm, depends on process connection pipe extension:- length 117 ... 6000 mm, 316L- length 148 ... 3000 mm, Alloy C22 tuning fork: width 17.2 mm, fork width 10 mm, length 40 mm For further information see technical information (TI).
Process connectioncylindrical threads G3/4, G1 acc. to DIN ISO 228 G for installing in weld-in adapter cylindrical threads G3/4, G1 acc. to DIN ISO 228 G with flat seal conical threads NPT3/4, NPT1 acc. to ANSI B 1.20.3 conical threads R3/4, R1 acc. to EN 10226 flanges RF, RJF, FF from 1 inch acc. to ASME B16.5 flanges form A, B1, C, D, E from DN25 acc. to EN 1092-1 flanges RF from 10K 25A acc. to JIS B2220 Tri-Clamp from DN25 acc. to ISO 2852 For further information see technical information (TI).

Data for application in connection with hazardous areas

EU-type examination certificatesee instruction manuals

International approvals

CSA approvalsee instruction manuals
IECEx approvalsee instruction manuals

Indication and operation

Display elementsStandard: without display LED module VU120, optional Bluetooth module VU121, optional
Control elementsswitches on the electronic insert
Function testvia switches on the electronic insert test magnet , optional

Certificates and approvals

Overspill protectionsee approval (ZE)

General information

Supplementary documentationtechnical information (TI) manuals, brief instructions (BA, KA) instruction manuals Functional safety manuals (FY) Special documentation (SD)
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Accessories

Designationsee technical information (TI)
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G