Pepperl Fuchs LCR20
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Guided Level Radar |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can LCR20 be shipped?
LCR20 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LCR20 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LCR20 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LCR20, subject to availability and destination.
Level Radar. Device for level measurement in liquids, Radar measuring device with Bluetooth<sup>®</sup> wireless technology and HART communication, Measuring range up to 20 m in fluids, Process temperature up to 80 °C (176 °F), Process pressure up to 3 bar (43 psi), Accuracy up to ± 2 mm, Commissioning, operation and maintenance via P+F Level app, Configurable by PACTware. Measuring method: The device is a measuring system that functions according to the time-of-flight method. The distance from the reference point (process connection of the measuring device) to the product surface is measured.. Construction type: compact device. Series: LCR. Rated voltage: 10.5 ... 30 V DC. Current consumption: input current : max. 25 mA start-up current : max. 3.6 mA. Power consumption: input power : max. 675 mW. Surge protection: integrated. Start-up time: first stable measured value after 20 s at 24 V DC. Interface type: HART. Specification: 7.0. Supported functions: Additional Transmitter Status. Vendor ID: 0x005D. Device ID: 0x5DD3. Coding: signal encoding, FSK ±0.5 mA over current signal. Transfer rate: 1200 Bit/s. Load: min. 250 Ω. Interface type: Bluetooth. Detection range: max. 25 m. Configuration: commissioning, operation and maintenance via P+F Level app - can be activated/deactivated - password encryption. Communication: encrypted. Measured variable: distance between reference point and product surface. Measuring range: - device with 40 mm (1.5 inch) antenna: max. 15 m (49 foot) - device with 80 mm (3 inch) antenna: max. 20 m (66 foot). Operating frequency: approx. 26 GHz , K-Band. Transmitter radiated power: mean power density in the direction of the beam- at a distance of 1 m (3.3 foot): < 12 nW/cm2- at a distance of 5 m (16 foot): < 0.4 nW/cm2. Output signal: 4 ... 20 mA , measured value output and power supply. Signal on alarm: current output: 22.5 mA (in accordance with NAMUR recommendation NE 43)operating tool via digital communication (HART) or P+F Level (app)- status signal (as per NAMUR Recommendation NE 107)- plain text display with remedial action. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Low voltage: . Directive 2014/35/EUEN 61010-1:2010: . Directive 2014/35/EU: EN 61010-1:2010. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529:2001. Vibration resistance: DIN EN 60068-2-64 / IEC 60068-2-64. Climate class: DIN EN 60068-2-38/IEC 68-2-38. Bluetooth: IEEE 802.15.1. Accuracy: up to ± 2 mm. Process conditions: . Process temperature-40 ... 80 °C (-40 ... 176 °F)Process pressurethreaded process connection relative pressure : -1 ... 3 bar (-14.5 ... 43.5 psi) absolute pressure : < 4 bar (58 psi) UNI flange process connection relative pressure : -1 ... 1 bar (-14.5 ... 14.5 psi) absolute pressure : < 2 bar (29 psi)State of aggregationliquidDielectric constant4 ... 10 , e. g. concentrated acid, organic solvents, ester, aniline, alcohol, acetone, ... > 10 , e.g. conductive liquids, aqueous solutions, diluted acids and bases: . Process temperature: -40 ... 80 °C (-40 ... 176 °F). Process pressure: threaded process connection relative pressure : -1 ... 3 bar (-14.5 ... 43.5 psi) absolute pressure : < 4 bar (58 psi) UNI flange process connection relative pressure : -1 ... 1 bar (-14.5 ... 14.5 psi) absolute pressure : < 2 bar (29 psi). State of aggregation: liquid. Dielectric constant: 4 ... 10 , e. g. concentrated acid, organic solvents, ester, aniline, alcohol, acetone, ... > 10 , e.g. conductive liquids, aqueous solutions, diluted acids and bases. Ambient temperature: -40 ... 80 °C (-40 ... 176 °F) -40 ... 60 °C (-40 ... 140 °F) when using the Bluetooth connection. Storage temperature: -40 ... 80 °C (-40 ... 176 °F). Vibration resistance: 20 ... 2000 Hz, 1 (m/s2)2/Hz. Degree of protection: IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP66, NEMA 4X. Connection: cable 2 x 0,75 mm2. Material: sensor housing: PVDFseal: EPDMback side process connection: PVDFcable gland: PAconduit adapter: CuZn nickel-platedO-ring: EPDMcounter nut: PA6.6design ring: PBT-PCfront side process connection: PVDFcable: PVC. Cable: . LengthL5 m 10 m 20 m specified length, any length from 5 to 300 m (16 ... 980 foot): L. Length: 5 m 10 m 20 m specified length, any length from 5 to 300 m (16 ... 980 foot). Mass: - device with 40 mm (1.5 inch) antenna with 5 m cable: 2.5 kg - device with 80 mm (3 inch) antenna with 5 m cable: 2.8 kg. Dimensions: - device with 40 mm (1.5 inch) antenna: ∅75 x 140 mm - device with 80 mm (3 inch) antenna: ∅115 x 206 mm. Process connection: Back side: thread ISO228 G1, ASME MNPT1 Front side: - thread ISO228 G1-1/2, ASME MNPT1-1/2 - thread ISO228 G2, ASME MNPT2 - UNI slip on flange 3 inch/DN80/80, 4 inch/DN100/100, 6 inch/DN150/150. EU-type examination certificate: see instruction manuals. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-26:2015: . Directive 2014/34/EU: EN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-26:2015. CSA approval: see instruction manuals (SI). IECEx approval: see instruction manuals. Telecommunications: radio license FCC. Supplementary documentation: technical information (TI) manuals, brief instructions (BA, KA) instruction manuals. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.. Designation: see technical information (TI)
Specifications
General specifications
| Measuring method | The device is a measuring system that functions according to the time-of-flight method. The distance from the reference point (process connection of the measuring device) to the product surface is measured. |
| Construction type | compact device |
| Series | LCR |
Supply
| Rated voltage | 10.5 ... 30 V DC Ur |
| Current consumption | input current : max. 25 mA start-up current : max. 3.6 mA |
| Power consumption | input power : max. 675 mW |
Electrical specifications
| Surge protection | integrated |
| Start-up time | first stable measured value after 20 s at 24 V DC |
Interface 1
| Interface type | HART |
| Specification | 7.0 |
| Supported functions | Additional Transmitter Status |
| Vendor ID | 0x005D |
| Device ID | 0x5DD3 |
| Coding | signal encoding, FSK ±0.5 mA over current signal |
| Transfer rate | 1200 Bit/s |
| Load | min. 250 Ω |
Interface 2
| Interface type | Bluetooth |
| Detection range | max. 25 m |
| Configuration | commissioning, operation and maintenance via P+F Level app - can be activated/deactivated - password encryption |
| Communication | encrypted |
Input
| Measured variable | distance between reference point and product surface |
| Measuring range | - device with 40 mm (1.5 inch) antenna: max. 15 m (49 foot) - device with 80 mm (3 inch) antenna: max. 20 m (66 foot) |
| Operating frequency | approx. 26 GHz , K-Band |
| Transmitter radiated power | mean power density in the direction of the beam- at a distance of 1 m (3.3 foot): < 12 nW/cm2- at a distance of 5 m (16 foot): < 0.4 nW/cm2 |
Output
| Output signal | 4 ... 20 mA , measured value output and power supply |
| Signal on alarm | current output: 22.5 mA (in accordance with NAMUR recommendation NE 43)operating tool via digital communication (HART) or P+F Level (app)- status signal (as per NAMUR Recommendation NE 107)- plain text display with remedial action |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Low voltage | |
| Directive 2014/35/EUEN 61010-1:2010 | Directive 2014/35/EU |
| Directive 2014/35/EU | EN 61010-1:2010 |
Conformity
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529:2001 |
| Vibration resistance | DIN EN 60068-2-64 / IEC 60068-2-64 |
| Climate class | DIN EN 60068-2-38/IEC 68-2-38 |
| Bluetooth | IEEE 802.15.1 |
Measurement accuracy
| Accuracy | up to ± 2 mm |
Operating conditions
| Process conditions | |
| Process temperature-40 ... 80 °C (-40 ... 176 °F)Process pressurethreaded process connection relative pressure : -1 ... 3 bar (-14.5 ... 43.5 psi) absolute pressure : < 4 bar (58 psi) UNI flange process connection relative pressure : -1 ... 1 bar (-14.5 ... 14.5 psi) absolute pressure : < 2 bar (29 psi)State of aggregationliquidDielectric constant4 ... 10 , e. g. concentrated acid, organic solvents, ester, aniline, alcohol, acetone, ... > 10 , e.g. conductive liquids, aqueous solutions, diluted acids and bases | Process temperature |
| Process temperature | -40 ... 80 °C (-40 ... 176 °F) |
| Process pressure | threaded process connection relative pressure : -1 ... 3 bar (-14.5 ... 43.5 psi) absolute pressure : < 4 bar (58 psi) UNI flange process connection relative pressure : -1 ... 1 bar (-14.5 ... 14.5 psi) absolute pressure : < 2 bar (29 psi) |
| State of aggregation | liquid |
| Dielectric constant | 4 ... 10 , e. g. concentrated acid, organic solvents, ester, aniline, alcohol, acetone, ... > 10 , e.g. conductive liquids, aqueous solutions, diluted acids and bases |
Ambient conditions
| Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) -40 ... 60 °C (-40 ... 140 °F) when using the Bluetooth connection |
| Storage temperature | -40 ... 80 °C (-40 ... 176 °F) |
| Vibration resistance | 20 ... 2000 Hz, 1 (m/s2)2/Hz |
Mechanical specifications
| Degree of protection | IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP66, NEMA 4X |
| Connection | cable 2 x 0,75 mm2 |
| Material | sensor housing: PVDFseal: EPDMback side process connection: PVDFcable gland: PAconduit adapter: CuZn nickel-platedO-ring: EPDMcounter nut: PA6.6design ring: PBT-PCfront side process connection: PVDFcable: PVC |
| Cable | |
| LengthL5 m 10 m 20 m specified length, any length from 5 to 300 m (16 ... 980 foot) | L Length |
| Length | 5 m 10 m 20 m specified length, any length from 5 to 300 m (16 ... 980 foot) L |
| Mass | - device with 40 mm (1.5 inch) antenna with 5 m cable: 2.5 kg - device with 80 mm (3 inch) antenna with 5 m cable: 2.8 kg |
| Dimensions | - device with 40 mm (1.5 inch) antenna: ∅75 x 140 mm - device with 80 mm (3 inch) antenna: ∅115 x 206 mm |
| Process connection | Back side: thread ISO228 G1, ASME MNPT1 Front side: - thread ISO228 G1-1/2, ASME MNPT1-1/2 - thread ISO228 G2, ASME MNPT2 - UNI slip on flange 3 inch/DN80/80, 4 inch/DN100/100, 6 inch/DN150/150 |
Data for application in connection with hazardous areas
| EU-type examination certificate | see instruction manuals |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-26:2015 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-26:2015 |
International approvals
| CSA approval | see instruction manuals (SI) |
| IECEx approval | see instruction manuals |
Certificates and approvals
| Telecommunications | radio license FCC |
General information
| Supplementary documentation | technical information (TI) manuals, brief instructions (BA, KA) instruction manuals |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |