What is the Pepperl Fuchs LB5104A?

4 channels

Inputs Ex ia

Mounting in Zone 2, Class I/Div.2 or in the safe area

Converter for 2-, 3- and 4-wire RTDs (Pt100 ... Pt1000), slide wire sensors etc.

Simulation mode for service operations (forcing)

Line fault detection (LFD)

Permanently self-monitoring

Module can be exchanged under voltage

4 channels, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Converter for 2-, 3- and 4-wire RTDs (Pt100 ... Pt1000), slide wire sensors etc., Explosion protection: Ex ia, Field device: resistance thermometer, Field device [2]: slide-wire sensors, Field device [3]: potentiometer, Connection: 2-wire sensor, Connection [2]: 3-wire sensor, Connection [3]: 4-wire sensor

Specifications

Slots

Order code (Pepperl+Fuchs part number)254810
Occupied slots2
LifecycleActive (current Pepperl+Fuchs product)

Supply

Connectionbackplane bus
Rated voltage12 V DC , only in connection with the power supplies LB9*** Ur
Power dissipation0.35 W
Power consumption0.35 W

Internal bus

Connectionbackplane bus
Interfacemanufacturer-specific bus to standard com unit

temperature input

Number of channels4
Suitable field devices: Field deviceresistance thermometer
Suitable field devices: Field device [2]slide-wire sensors
Suitable field devices: Field device [3]potentiometer
Field device interface: Connection2-wire sensor
Field device interface: Connection [2]3-wire sensor
Field device interface: Connection [3]4-wire sensor
Connectionchannel I: resistance/potentiometer input 1 ... 4 channel II: resistance/potentiometer input 5 ... 8 channel III: resistance/potentiometer input 9 ... 12 channel IV: resistance/potentiometer input 13 ... 16
Measuring rangePt100 (18-390 Ω) (500 Ω incl. line resistance) Pt200 (37-780 Ω) Pt500 (92-1952 Ω) Pt1000 (185-3905 Ω) Ni100 (69-270 Ω) Ni500 (345-1350 Ω) Ni1000 (690-2700 Ω)
Slide-wire sensor0 ... 10 kΩ
Measuring current200 µA
Smallest span50 Ω for 0.1 % accuracy
Linearity error0.1 %
Conversion timemax. 500 ms (4 channels) max. 1 s (for 4x 3-wire Pt100)
Busy after download5 ... 15 s
Lead resistancemax. 50 Ω per strand
Line fault detectioncan be switched on/off for each channel via configuration tool
Short-circuit< 10 Ω
Open-circuit> 1 kΩ

Transfer characteristics

Deviation: Influence of ambient temperaturemax. 0,1 %/10 K

Indicators/settings

LED indicationPower LED (P) green: supply Status LED (I) red: line fault (collective alarm) , red flashing: communication error
Codingoptional mechanical coding via front socket

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013

Conformity

Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Environmental testEN 60068-2-14
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Damaging gasEN 60068-2-42
Relative humidityEN 60068-2-78

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity95 % non-condensing
Altitudemax. 2000 m
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Degree of protectionIP20 when mounted on backplane
Connectionremovable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Massapprox. 150 g
Dimensions: Height100 mm
Dimensions: Width32.5 mm
Dimensions: Depth102 mm

Data for application in connection with hazardous areas

EU-type examination certificatePTB 03 ATEX 2042 X
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Input: Voltage7.14 V Uo
Input: Current70 mA Io
Input: Power123 mW (linear characteristic) Po
CertificatePF 08 CERT 1234 X
MarkingII 3 G Ex nA IIC T4 Gc
Galvanic isolation: Input/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010

International approvals

ATEX approvalPTB 03 ATEX 2042 X
UL approvalE106378
IECEx approval: IECEx certificateIECEx BVS 09.0037X
IECEx approval: IECEx markingEx nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I

General information

System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

LB5104A: frequently asked questions

When can LB5104A be shipped?

LB5104A is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up LB5104A in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for LB5104A and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LB5104A, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs LB5004A – RTD Converter
Pepperl Fuchs
LB5004A

RTD Converter

Pepperl Fuchs LB5005A – Thermocouple Converter
Pepperl Fuchs
LB5005A

Thermocouple Converter

Pepperl Fuchs LB5101A – RTD Converter
Pepperl Fuchs
LB5101A

RTD Converter

Pepperl Fuchs LB5102A – Thermocouple Converter
Pepperl Fuchs
LB5102A

Thermocouple Converter

Pepperl Fuchs LB5105A – Thermocouple Converter
Pepperl Fuchs
LB5105A

Thermocouple Converter

Pepperl Fuchs LB5106A – Voltage Converter
Pepperl Fuchs
LB5106A

Voltage Converter

Pepperl Fuchs LB6001A2 – Relay output
Pepperl Fuchs
LB6001A2

Relay output

Pepperl Fuchs LB6006A – Relay output
Pepperl Fuchs
LB6006A

Relay output

Pepperl Fuchs LB5104APrice and lead time confirmed within 1 business day
Request a Quote