Pepperl Fuchs LB2016E

Digital Output with Position Feedback

MPN
LB2016E
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

What happens next
  1. We check stock, condition and lead time
  2. You get a written quote by email
  3. Approve it and we ship — in-stock parts within 1 business day
  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via
  • 100% positive eBay feedback

Have spare Pepperl Fuchs parts? We buy surplus →

What is the Pepperl Fuchs LB2016E?

1-channel

1 digital output, 2 digital inputs

Installation in Zone 2 or safe area

Inputs and output Ex ic

Line fault detection switched on and off

Positive or negative logic selectable

Simulation mode for service operations (forcing)

Permanently self-monitoring

Output with watchdog

Output with bus-independent safety shutdown

Module can be exchanged under voltage

1-channel, 1 digital output, 2 digital inputs, Installation in Zone 2 or safe area, Inputs and output Ex ic, Explosion protection: Ex ic

Specifications

Slots

Order code (Pepperl+Fuchs part number)281971
Occupied slots1
LifecycleActive (current Pepperl+Fuchs product)

Supply

Connectionbackplane bus
Rated voltageUse only in connection with the power supplies LB9*** Ur
Power dissipation1.3 W
Power consumption1.85 W

Internal bus

Connectionbackplane bus
Interfacemanufacturer-specific bus to standard com unit

Digital input

Number of channels2
Sensor interface: ConnectionNAMUR sensor
Sensor interface: Connection [2]volt-free contact
Connectionchannel I: 2+, 5-; channel II: 3+, 6-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Switching point/switching hysteresis1.2 ... 2.1 mA / ± 0.2 mA
Voltage8.2 V
Internal resistor1 kΩ Ri
Line fault detectioncan be switched on/off for each channel via configuration tool
Connectionmechanical switch with additional resistors (see connection diagram) proximity sensors without additional wiring
Short-circuit< 360 Ω
Open-circuit< 0.35 mA
Minimum pulse duration1 ms

Digital output

Number of channels1
Suitable field devices: Field deviceSolenoid Valve
Suitable field devices: Field device [2]audible alarm
Suitable field devices: Field device [3]visual alarm
Connectionchannel I: 1+, 4-
Internal resistor258 Ω Ri
Current limit40 mA Imax
Open loop voltage23 V Us
Line fault detectioncan be switched on/off for each channel via configuration tool , also when turned off (every 2.5 s the valve is turned on for 2 ms)
Short-circuit< 50 Ω
Open-circuit> 10 kΩ
Response time20 ms (depending on bus cycle time)
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication

Indicators/settings

LED indicationPower LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (O: output, I1: input 1, I2: input 2) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1)
Codingoptional mechanical coding via front socket

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013

Conformity

Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Environmental testEN 60068-2-14
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Damaging gasEN 60068-2-42
Relative humidityEN 60068-2-78

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity95 % non-condensing
Altitudemax. 2000 m
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Degree of protectionIP20 when mounted on backplane
Connectionremovable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Massapprox. 150 g
Dimensions: Height100 mm
Dimensions: Width16 mm
Dimensions: Depth102 mm

Data for application in connection with hazardous areas

EU-type examination certificateEXA 16 ATEX 0035X
MarkingII 3 G Ex nA [ic] IIC T4 Gc
Input: Voltage10 V Uo
Input: Current13 mA Io
Input: Power33 mW (linear characteristic) Po
Input: Internal capacitance1.2 nF Ci
Input: Internal inductance0 mH Li
Output: Voltage24.2 V Uo
Output: Current108 mA Io
Output: Power654 mW Po
Output: Internal capacitance12 nF Ci
Output: Internal inductance0 mH Li
Galvanic isolation: Input/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Galvanic isolation: Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010

International approvals

ATEX approvalEXA 16 ATEX 0035X
IECEx approvalIECEx EXA 16.0010X
Approved forEx nA [ic] IIC T4 Gc

General information

System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

LB2016E: frequently asked questions

When can LB2016E be shipped?

LB2016E is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up LB2016E in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for LB2016E and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LB2016E, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs LB1101A – Digital Input
Pepperl Fuchs
LB1101A

Digital Input

Pepperl Fuchs LB1103A – Frequency / Counter Input
Pepperl Fuchs
LB1103A

Frequency / Counter Input

Pepperl Fuchs LB1108A – Digital Input
Pepperl Fuchs
LB1108A

Digital Input

Pepperl Fuchs LB1109A – Digital Input
Pepperl Fuchs
LB1109A

Digital Input

Pepperl Fuchs LB2116E – Digital Output with Position Feedback
Pepperl Fuchs
LB2116E

Digital Output with Position Feedback

Pepperl Fuchs LB3002A2 – HART Transmitter Power Supply, Input Isolator
Pepperl Fuchs
LB3002A2

HART Transmitter Power Supply, Input Isolator

Pepperl Fuchs LB3005A2 – HART Transmitter Power Supply, Input Isolator
Pepperl Fuchs
LB3005A2

HART Transmitter Power Supply, Input Isolator

Pepperl Fuchs LB3006A – HART Transmitter Power Supply
Pepperl Fuchs
LB3006A

HART Transmitter Power Supply

Pepperl Fuchs LB2016EPrice and lead time confirmed within 1 business day
Request a Quote