What is the Pepperl Fuchs LB1009A?

8-channel

Inputs Ex ic

Installation in Zone 2 or safe area

Dry contact or NAMUR inputs

Positive or negative logic selectable

Simulation mode for service operations (forcing)

Line fault detection (LFD)

Permanently self-monitoring

Module can be exchanged under voltage

8-channel, Inputs Ex ic, Installation in Zone 2 or safe area, Dry contact or NAMUR inputs, Explosion protection: Ex ic, Connection: NAMUR sensor, Connection [2]: volt-free contact

Specifications

Slots

Order code (Pepperl+Fuchs part number)244407
Occupied slots1
LifecycleActive (current Pepperl+Fuchs product)

Supply

Connectionbackplane bus
Rated voltage12 V DC , only in connection with the power supplies LB9*** Ur
Power dissipation1.55 W
Power consumption1.55 W

Internal bus

Connectionbackplane bus
Interfacemanufacturer-specific bus to standard com unit

Digital input

Number of channels8
Sensor interface: ConnectionNAMUR sensor
Sensor interface: Connection [2]volt-free contact
Sensor interface: Connection [3]Usage without connection to areas where there is a risk of explosion: active signals, mechanical contacts, NAMUR sensors, 2-wire sensors If the device has been operated in general electrical systems that are not connected to areas where there is a risk of explosion, the device cannot then be used in electrical systems that are connected to areas where there is a risk of explosion. Usage with connection to areas where there is a risk of explosion: mechanical contacts, NAMUR sensors
ConnectionTerminals 1+, 2-, 3+, 4-, 5+, 6-, 7+, 8-, 9+, 10-, 11+, 12-, 13+,14-, 15+, 16-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Switching point/switching hysteresis1.2 ... 2.1 mA / ± 0.2 mA
Voltage8.2 V
Internal resistor1 kΩ Ri
Line fault detectioncan be switched on/off for each channel via configuration tool , active signals (24 V, 5 V) without line fault detection
Connectionmechanical switch with additional resistors (see connection diagram) proximity sensors without additional wiring
Short-circuit< 360 Ω
Open-circuit< 0.35 mA
Digital signals (active)Use in safe area: configurable 24 V 5 V
Switching point: ON> 8 V > 2.7 V
Switching point: OFF< 3 V < 2.3 V
Minimum pulse duration15 ms

Indicators/settings

LED indicationPower LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-8) red: line fault (lead breakage or short circuit) , yellow: signal (per channel)
Codingoptional mechanical coding via front socket

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013

Conformity

Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Environmental testEN 60068-2-14
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Damaging gasEN 60068-2-42
Relative humidityEN 60068-2-78

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F) , 70 °C (non-Ex)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity95 % non-condensing
Altitudemax. 2000 m
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Degree of protectionIP20 when mounted on backplane
Connectionremovable front connector with spring terminal (0.14 ... 0.5 mm2)
Massapprox. 90 g
Dimensions: Height100 mm
Dimensions: Width16 mm
Dimensions: Depth102 mm

Data for application in connection with hazardous areas

Input: Voltage10 V Uo
Input: Current12 mA Io
Input: Power30 mW (linear characteristic) Po
CertificateEXA 13 ATEX 0037X
MarkingII 3 G Ex nA [ic] IIC T4 Gc
Galvanic isolation: Input/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010

International approvals

ATEX approvalEXA 13 ATEX 0037X
IECEx approval: IECEx certificateIECEx EXA 13.0003X
IECEx approval: IECEx markingEx nA [ic] IIC T4 Gc

General information

System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

LB1009A: frequently asked questions

When can LB1009A be shipped?

LB1009A is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up LB1009A in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for LB1009A and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LB1009A, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs LB1001A – Digital Input
Pepperl Fuchs
LB1001A

Digital Input

Pepperl Fuchs LB1003A – Frequency / Counter Input
Pepperl Fuchs
LB1003A

Frequency / Counter Input

Pepperl Fuchs LB1008A – Digital Input
Pepperl Fuchs
LB1008A

Digital Input

Pepperl Fuchs LB1101A – Digital Input
Pepperl Fuchs
LB1101A

Digital Input

Pepperl Fuchs LB1103A – Frequency / Counter Input
Pepperl Fuchs
LB1103A

Frequency / Counter Input

Pepperl Fuchs LB1108A – Digital Input
Pepperl Fuchs
LB1108A

Digital Input

Pepperl Fuchs LB1109A – Digital Input
Pepperl Fuchs
LB1109A

Digital Input

Pepperl Fuchs LB1009APrice and lead time confirmed within 1 business day
Request a Quote