Pepperl Fuchs KCD2-SR-1.LB.SP

Switch Amplifier

MPN
KCD2-SR-1.LB.SP
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Pepperl Fuchs parts? We buy surplus →

What is the Pepperl Fuchs KCD2-SR-1.LB.SP?

1-channel signal conditioner

24 V DC supply (Power Rail)

Dry contact or NAMUR inputs

Usable as signal splitter (1 input and 2 outputs)

Relay contact output

Fault relay contact output

Line fault detection (LFD)

Housing width 12.5 mm

Connection via spring terminals with push-in connection technology

Up to SIL 2 (SC 3) acc. to IEC/EN 61508

1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC

Specifications

General specifications

Order code (Pepperl+Fuchs part number)70112149
Signal typeDigital Input
LifecycleActive (current Pepperl+Fuchs product)

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2
Systematic capability (SC)SC 3

Supply

ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC Ur
Ripple≤ 10 %
Rated current≤ 37 mA Ir
Power dissipation≤ 750 mW
Power consumption≤ 750 mW

Input

Connection sidefield side
Connectionterminals 1+, 2-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit currentapprox. 8 V DC / approx. 8 mA
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detectionbreakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
Pulse/Pause ratiomin. 20 ms / min. 20 ms

Output

Safety noteIf load voltage > 50 V, de-energize before removing the terminals.
Connection sidecontrol side
Connectionoutput I: terminals 5, 6 ; output II: terminals 7, 8
Output Isignal ; relay
Output IIsignal or fault message ; relay
Contact loading250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load
Minimum switch current2 mA / 24 V DC
Energized/De-energized delay≤ 20 ms / ≤ 20 ms
Mechanical life107 switching cycles

Transfer characteristics

Switching frequency≤ 10 Hz

Galvanic isolation

Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elementsLEDs
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage: Directive 2014/35/EUEN 61010-1:2010+A1:2019+A1:2019/AC:2019

Conformity

Electromagnetic compatibilityNE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018
Degree of protectionIEC 60529:1989+A1:1999+A2:2013
Functional safetyIEC/EN 61508:2010
InputEN 60947-5-6:2000

Ambient conditions

Ambient temperature-40 ... 70 °C (-40 ... 158 °F)

Mechanical specifications

Degree of protectionIP20
Connectionspring terminals
Massapprox. 100 g
Dimensions12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2
Height119 mm
Width12.5 mm
Depth114 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Downloads & documentation

Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.

Data sheets & manuals

CAD & dimension drawings

Certificates (2)

KCD2-SR-1.LB.SP: frequently asked questions

When can KCD2-SR-1.LB.SP be shipped?

KCD2-SR-1.LB.SP is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KCD2-SR-1.LB.SP in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KCD2-SR-1.LB.SP and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-SR-1.LB.SP, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KCD2-SR-1 – Switch Amplifier
Pepperl Fuchs
KCD2-SR-1

Switch Amplifier

Pepperl Fuchs KCD2-SR-2 – Switch Amplifier
Pepperl Fuchs
KCD2-SR-2

Switch Amplifier

Pepperl Fuchs KCD2-SR-Ex1 – Switch Amplifier
Pepperl Fuchs
KCD2-SR-Ex1

Switch Amplifier

Pepperl Fuchs KCD2-SR-1.LB.SPPrice and lead time confirmed within 1 business day
Request a Quote