Pepperl Fuchs KCD2-SON-Ex1.R3
Switch Amplifier
- MPN
- KCD2-SON-Ex1.R3
- Category
- K-System (DIN Rail Mounting)
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs KCD2-SON-Ex1.R3?
1-channel isolated barrier
24 V DC supply (Power Rail)
Dry contact or NAMUR input
Application-specific outputs
Usable as signal splitter (1 input and 2 outputs)
2 passive transistor outputs (resistive)
Line fault transparency (LFT)
Housing width 12.5 mm
Up to SIL 2 (SC 3) acc. to IEC/EN 61508
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, Application-specific outputs, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs (resistive), Line fault transparency (LFT), Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 320208 |
| Signal type | Digital Input |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
| Systematic capability (SC) | SC 3 |
Supply
| Connection | Power Rail or terminals 9+, 10- |
| Rated voltage | 19 ... 30 V DC Ur |
| Ripple | ≤ 10 % |
| Rated current | 18 ... 14 mA Ir |
| Power dissipation | ≤ 500 mW |
Input
| Connection side | field side |
| Connection | terminals 1+, 2- |
| Rated values | acc. to EN 60947-5-6 (NAMUR) |
| Open circuit voltage/short-circuit current | approx. 10 V DC / approx. 8 mA |
| Switching point/switching hysteresis | 1.2 ... 2.1 mA / approx. 0.2 mA |
| Line fault detection | breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA |
| Pulse/Pause ratio | min. 100 µs / min. 100 µs |
Output
| Connection side | control side |
| Connection | output I: terminals 5, 6 ; output II: terminals 7, 8 |
| Rated voltage | 20 ... 28 V DC with external resistance > 2 kΩ Ur |
| Response time | ≤ 200 µs |
| Output I, II | signal or fault message, passive transistor output (resistive) 0-signal: 19 kΩ ±5 % 1-signal: 100 Ω ... 600 Ω fault: > 100 kΩ |
| Collective error message | Power Rail |
Transfer characteristics
| Switching frequency | ≤ 5 kHz |
Galvanic isolation
| Input/Output | reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff |
| Input/power supply | reinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff |
| Output/power supply | basic insulation according to EN 50178, rated insulation voltage 50 Veff |
| Output/Output | basic insulation according to EN 50178, rated insulation voltage 50 Veff |
Indicators/settings
| Display elements | LEDs |
| Control elements | DIP switch |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2011 , EN 61326-3-2:2008 |
| Degree of protection | IEC 60529:2001 |
| Protection against electrical shock | IEC 61010-1:2010 |
| Input | EN 60947-5-6:2000 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 100 g |
| Dimensions | 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | BASEEFA 13 ATEX 0080 |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Input | Ex ia |
| Voltage | 10.5 V Uo |
| Current | 17.1 mA Io |
| Power | 45 mW (linear characteristic) Po |
| Supply: Maximum safe voltage | 253 V AC (Attention! Um is no rated voltage.) Um |
| Output: Maximum safe voltage | 253 V AC (Attention! The rated voltage can be lower.) Um |
| Certificate | CML 19 ATEX 4410 X |
| Marking | II 3G Ex ec IIC T4 Gc |
| Galvanic isolation: Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Galvanic isolation: Input/power supply | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN IEC 60079-11:2024 |
International approvals
| UL approval: Control drawing | 116-0374 (cULus) |
| IECEx approval: IECEx certificate | IECEx BAS 13.0046 IECEx CML 19.0147X |
| IECEx approval: IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (10)
- Brasil TUV Rheinland Brazil (TÜV 23.1084 (Vietnam))
- China SITIIAS CCC Ex Certificate (2020322316001220 (Singapore))
- China SITIIAS CCC Ex Certificate (2025322316006499 (Vietnam))
- EU Declaration of Conformity (Pepperl+Fuchs)
- South Africa MASC (MASC MS/18-2756)
- DNV Marine (TAA00001WX)
- Europe CML ATEX Category 3 G (CML 19ATEX4410X)
- Canada USA UL Certificate of Compliance Hazardous Location UL E106378 cULus (CoC E106378 RepRef E106378-20140430)
- Europe Baseefa ATEX (Baseefa 13 ATEX 0080)
- exida Functional Safety Assessment (P+F 1005-041-C R032 V1R0)
KCD2-SON-Ex1.R3: frequently asked questions
When can KCD2-SON-Ex1.R3 be shipped?
KCD2-SON-Ex1.R3 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KCD2-SON-Ex1.R3 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KCD2-SON-Ex1.R3 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-SON-Ex1.R3, subject to availability and destination.