What is the Pepperl Fuchs KCD2-SCS-Ex2.SP?

2-channel isolated barrier

24 V DC supply (Power Rail)

Analog input (AI), Analog output (AO)

Operates as transmitter power supply or current driver

Housing width 12.5 mm

Connection via spring terminals with push-in connection technology

Up to SIL 2 (SC 3) acc. to IEC/EN 61508

2-channel isolated barrier, 24 V DC supply (Power Rail), Analog input (AI), Analog output (AO), Operates as transmitter power supply or current driver, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC

Specifications

General specifications

Order code (Pepperl+Fuchs part number)70166764
Signal typeAnalog input/analog output
LifecycleActive (current Pepperl+Fuchs product)

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2
Systematic capability (SC)SC 3

Supply

ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC Ur
Ripplemax. 10 %
Rated currentmax. 88 mA at 24 V Ir
Power dissipationmax. 1.4 W
Power consumptionmax. 2.1 W

Analog input

Number of channels2
Suitable field devices2-wire SMART transmitters
Signal0/4 ... 20 mA , limited to approx. 30 mA
Field circuitterminals 1+, 2-, 3+, 4-
Available voltagemin. 15 V at 20 mA min. 18 V at 4 mA
Control circuitterminals 5-, 6+; 7-, 8+ limited electrical values : max. 30 V , max. 2 A
Input voltageVoltage across terminals 10 ... 30 V. If the current is supplied from a source > 24 V, series resistance of ≥ (V - 24)/0.02 Ω is needed, where V is the source voltage. The maximum value of the resistance is (V - 10)/0.02 Ω. (sink output)
Loadmax. 350 Ω (source output)
Ripple20 mV eff

Analog output

Number of channels2
Suitable field devicesSMART I/P converters (positioner), on-site-displays
Signal0/4 ... 20 mA , limited to approx. 30 mA
Field circuitterminals 1+, 2-, 3+, 4-
Loadmax. 650 Ω
Voltagemin. 13 V at 20 mA
Ripple20 mV eff , on all signal terminals
Control circuitterminals 5-, 6+; 7-, 8+ limited electrical values : max. 30 V , max. 2 A
Voltage dropmax. 6 V
Line fault detection> 100 kΩ at max. 30 V, with field wiring open

Transfer characteristics

Deviationmax. 20 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage
Influence of ambient temperature< 2 µA/K (-40 ... 70 °C (-40 ... 158 °F))
Frequency rangefield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB)
Settling timemax. 200 ms
Rise time/fall timemax. 100 ms (10 ... 90 %)

Galvanic isolation

Field circuit/control circuitbasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Control circuit/control circuitfunctional isolation, rated voltage: 50 V
Field circuit/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Control/power supplybasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elementsLED
Factory settinganalog input with source output
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2017 EN 61326-3-2:2018
Degree of protectionIEC 60529:2001
Protection against electrical shockUL 61010-1:2019

Ambient conditions

Ambient temperature-40 ... 70 °C (-40 ... 158 °F)

Mechanical specifications

Degree of protectionIP20
Connectionspring terminals
Massapprox. 115 g
Dimensions12.5 x 124 x 114 mm (0.5 x 4.9 x 4.5 inch) (W x H x D) , housing type A2
Height124 mm
Width12.5 mm
Depth114 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateUL 22 ATEX 2786 X
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
OutputEx ia, Ex iaD
Voltage25.2 V Uo
Current100 mA Io
Power630 mW Po
Internal capacitance1.05 nF Ci
Internal inductance0 Li
Supply: Maximum safe voltage250 V rms (Attention! The rated voltage can be lower.) Um
Input: Maximum safe voltage250 V rms (Attention! The rated voltage can be lower.) Um
CertificateUL 22 ATEX 2787 X
MarkingII 3G Ex ec IIC T4 Gc [device in zone 2]
Galvanic isolation: Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Galvanic isolation: Field circuit/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-11:2012 , EN IEC 60079-7:2015+A1:2018

International approvals

UL approvalE106378
Control drawing116-0490 (cULus)
IECEx approval: IECEx certificateIECEx ULD 22.0020X
IECEx approval: IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KCD2-SCS-Ex2.SP: frequently asked questions

When can KCD2-SCS-Ex2.SP be shipped?

KCD2-SCS-Ex2.SP is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KCD2-SCS-Ex2.SP in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KCD2-SCS-Ex2.SP and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KCD2-SCS-Ex2.SP, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KCD2-SCS-2 – SMART Transmitter Power Supply/SMART Current Driver
Pepperl Fuchs
KCD2-SCS-2

SMART Transmitter Power Supply/SMART Current Driver

Pepperl Fuchs KCD2-SCS-2.SP – SMART Transmitter Power Supply/SMART Current Driver
Pepperl Fuchs
KCD2-SCS-2.SP

SMART Transmitter Power Supply/SMART Current Driver

Pepperl Fuchs KCD2-SCS-Ex2 – SMART Transmitter Power Supply/SMART Current Driver
Pepperl Fuchs
KCD2-SCS-Ex2

SMART Transmitter Power Supply/SMART Current Driver

Pepperl Fuchs KCD2-SCS-Ex2.SPPrice and lead time confirmed within 1 business day
Request a Quote