Pepperl Fuchs IUH-F190-V1-FR1-01-Ex GUBW1
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | RFID Read/Write Devices |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can IUH-F190-V1-FR1-01-Ex GUBW1 be shipped?
IUH-F190-V1-FR1-01-Ex GUBW1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up IUH-F190-V1-FR1-01-Ex GUBW1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for IUH-F190-V1-FR1-01-Ex GUBW1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IUH-F190-V1-FR1-01-Ex GUBW1, subject to availability and destination.
RFID read/write device hazardous area. UHF RFID read/write device for IDENT Control , Europe, hazardous areas. Operating frequency: 865 … 868 MHz: EU, TurkeyTransmission licenses for other countries on request. Emitted power: 3 ... 1000 mW ERP adjustable. LED green: Power on. LED yellow: Read/write operation successful. LED blue: Transmission mode. Power consumption: ≤ 9 W. Supply: from the IDENTControl. Radio equipment: . Directive 2014/53/EUEN 301489-1 EN 301489-3 EN 302208 EN 62368-1 EN 62311 EN 50364: . Directive 2014/53/EU: EN 301489-1 EN 301489-3 EN 302208 EN 62368-1 EN 62311 EN 50364. RoHS: . Directive 2011/65/EU (RoHS)IEC/EN 63000: . Directive 2011/65/EU (RoHS): IEC/EN 63000. Degree of protection: EN 60529. RFID: ISO/IEC 18000-63. IECEx approval: IECEx INE 14.0042X. ATEX approval: INERIS 14 ATEX 0035X Device type: GUBW1.D.CP-IUH-F190-V1-FR1-01 Device number: 70117534. Marking II 2 GDEx db IIC T6 GbEx tb IIIC T85°C Db: . Marking: II 2 GDEx db IIC T6 GbEx tb IIIC T85°C Db. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F) (Operation with nontransmission periods, adjustable) -20 ... 50 °C (-4 ... 122 °F) (Continuous transmission mode). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Degree of protection: IP66. Connection: Terminal block with screw connectionMax. clamping range 0.13 mm² ... 2.5 mm² M20 barrier gland for unarmored cables, clamping range 3 mm ... 8.5 mm. Material: . HousingSeawater-resistant aluminum: . Housing: Seawater-resistant aluminum. Installation: . Distance between two headsMultiplex on: ≥ 155 mm Multiplex off: ≥ 350 mm: . Distance between two heads: Multiplex on: ≥ 155 mm Multiplex off: ≥ 350 mm. Mass: approx. 7300 g. Dimensions: . Height134 mmWidth202 mmLength279 mm: . Height: 134 mm. Width: 202 mm. Length: 279 mm
Specifications
General specifications
| Operating frequency | 865 … 868 MHz: EU, TurkeyTransmission licenses for other countries on request |
| Emitted power | 3 ... 1000 mW ERP adjustable |
Indicators/operating means
| LED green | Power on |
| LED yellow | Read/write operation successful |
| LED blue | Transmission mode |
Electrical specifications
| Power consumption | ≤ 9 W P0 |
| Supply | from the IDENTControl |
Directive conformity
| Radio equipment | |
| Directive 2014/53/EUEN 301489-1 EN 301489-3 EN 302208 EN 62368-1 EN 62311 EN 50364 | Directive 2014/53/EU |
| Directive 2014/53/EU | EN 301489-1 EN 301489-3 EN 302208 EN 62368-1 EN 62311 EN 50364 |
| RoHS | |
| Directive 2011/65/EU (RoHS)IEC/EN 63000 | Directive 2011/65/EU (RoHS) |
| Directive 2011/65/EU (RoHS) | IEC/EN 63000 |
Standard conformity
| Degree of protection | EN 60529 |
| RFID | ISO/IEC 18000-63 |
Approvals and certificates
| IECEx approval | IECEx INE 14.0042X |
| ATEX approval | INERIS 14 ATEX 0035X Device type: GUBW1.D.CP-IUH-F190-V1-FR1-01 Device number: 70117534 |
| Marking II 2 GDEx db IIC T6 GbEx tb IIIC T85°C Db | Marking |
| Marking | II 2 GDEx db IIC T6 GbEx tb IIIC T85°C Db |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) (Operation with nontransmission periods, adjustable) -20 ... 50 °C (-4 ... 122 °F) (Continuous transmission mode) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications
| Degree of protection | IP66 |
| Connection | Terminal block with screw connectionMax. clamping range 0.13 mm² ... 2.5 mm² M20 barrier gland for unarmored cables, clamping range 3 mm ... 8.5 mm |
| Material | |
| HousingSeawater-resistant aluminum | Housing |
| Housing | Seawater-resistant aluminum |
| Installation | |
| Distance between two headsMultiplex on: ≥ 155 mm Multiplex off: ≥ 350 mm | Distance between two heads |
| Distance between two heads | Multiplex on: ≥ 155 mm Multiplex off: ≥ 350 mm |
| Mass | approx. 7300 g |
| Dimensions | |
| Height134 mmWidth202 mmLength279 mm | Height |
| Height | 134 mm |
| Width | 202 mm |
| Length | 279 mm |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs IUC87-F257-T19-M-FR2 10 pcs – RFID Transponder. Tag for autoclave applications. Operating…
Available on requestPepperl Fuchs IUC88-25L100-GBL 1000pcs – RFID Transponder. RFID Transponder. Operating frequency…
Available on requestPepperl Fuchs IUC88-C1-GBL 10pcs – RFID Transponder. RFID Transponder. Operating frequency…
Available on requestPepperl Fuchs IUH-F190-V1-FR1-01
Available on requestPepperl Fuchs IUH-F190-V1-FR1-04
Available on requestPepperl Fuchs IUH-F190-V1-FR1-15
Available on requestPepperl Fuchs IUH-F190-V1-FR2-02
Available on requestPepperl Fuchs IUH-F190-V1-FR2-03