Pepperl Fuchs HiC2841
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | H-System (Termination Board Mounting) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can HiC2841 be shipped?
HiC2841 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up HiC2841 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for HiC2841 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for HiC2841, subject to availability and destination.
Switch Amplifier. 1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 passive transistor outputs, Fault transistor output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Field device: NAMUR sensor. Signal type: Digital Input. Safety Integrity Level (SIL): SIL 2. Systematic capability (SC): SC 3. Connection: SL1: 1a, 1b(-); 2a, 2b(+). Rated voltage: 19 ... 30 V DC bus powered via Termination Board. Ripple: ≤ 10 %. Rated current: ≤ 25 mA. Power dissipation: ≤ 500 mW. Power consumption: ≤ 600 mW. Connection side: field side. Connection: SL2: 5a(+), 5b(-). Rated values: acc. to EN 60947-5-6 (NAMUR), see manual for electrical data. Open circuit voltage/short-circuit current: approx. 10 V DC / approx. 8 mA. Switching point/switching hysteresis: 1.2 ... 2.1 mA / approx. 0.2 mA. Line fault detection: breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA. Pulse/Pause ratio: min. 100 µs / min. 100 µs. Connection side: control side. Connection: SL1: 8a(+), 7a(-); 10a(+), 9a(-). Rated voltage: 30 V DC. Rated current: 50 mA. Response time: ≤ 200 µs. Signal level: 1-signal: (external voltage) - 1 V max. for 50 mA (Tamb = 25 °C (77 °F)) 0-signal: blocked output (off-state current ≤ 10 µA). Output I: signal ; Transistor. Output II: signal or fault message ; Transistor. Connection: SL1: 6b. Output type: open collector transistor (internal fault bus). Switching frequency: ≤ 5 kHz. Output/power supply: basic insulation acc. to EN 50178, rated insulation voltage of 50 V AC. Output/Output: basic insulation acc. to EN 50178, rated insulation voltage of 50 V AC. Display elements: LEDs. Control elements: DIP switch. Factory setting: input close, transistor closed, lead fault detection enabled. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Galvanic isolation: EN 50178:1997. Electromagnetic compatibility: NE 21:2012For further information see system description.. Degree of protection: IEC 60529:2001. Protection against electrical shock: IEC 61140. Ambient temperature: -40 ... 70 °C (-40 ... 158 °F). Relative humidity: ≤ 90 % , non-condensing. Degree of protection: IP20. Mass: approx. 90 g. Dimensions: 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D). Mounting: on termination board. Coding: pin 1 and 2 trimmed For further information see system description.. EU-type examination certificate: BVS 09 ATEX E 157. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IInputEx ia, Ex iaDVoltageUo10.5 VCurrentIo17.1 mAPowerPo45 mW (linear characteristic): . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Input: Ex ia, Ex iaD. Voltage: 10.5 V. Current: 17.1 mA. Power: 45 mW (linear characteristic). Supply: . Maximum safe voltageUm253 V AC (Attention! Um is no rated voltage.): Um. Maximum safe voltage: 253 V AC (Attention! Um is no rated voltage.). Output: . Maximum safe voltageUm253 V AC (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 253 V AC (Attention! The rated voltage can be lower.). Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Input/power supply: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000. UL approval: E106378. Control drawing116-0331: . Control drawing: 116-0331. IECEx approval: . IECEx certificateIECEx BVS 09.0060IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I: . IECEx certificate: IECEx BVS 09.0060. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Digital Input |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
| Systematic capability (SC) | SC 3 |
Supply
| Connection | SL1: 1a, 1b(-); 2a, 2b(+) |
| Rated voltage | 19 ... 30 V DC bus powered via Termination Board Ur |
| Ripple | ≤ 10 % |
| Rated current | ≤ 25 mA Ir |
| Power dissipation | ≤ 500 mW |
| Power consumption | ≤ 600 mW |
Input
| Connection side | field side |
| Connection | SL2: 5a(+), 5b(-) |
| Rated values | acc. to EN 60947-5-6 (NAMUR), see manual for electrical data |
| Open circuit voltage/short-circuit current | approx. 10 V DC / approx. 8 mA |
| Switching point/switching hysteresis | 1.2 ... 2.1 mA / approx. 0.2 mA |
| Line fault detection | breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA |
| Pulse/Pause ratio | min. 100 µs / min. 100 µs |
Output
| Connection side | control side |
| Connection | SL1: 8a(+), 7a(-); 10a(+), 9a(-) |
| Rated voltage | 30 V DC Ur |
| Rated current | 50 mA Ir |
| Response time | ≤ 200 µs |
| Signal level | 1-signal: (external voltage) - 1 V max. for 50 mA (Tamb = 25 °C (77 °F)) 0-signal: blocked output (off-state current ≤ 10 µA) |
| Output I | signal ; Transistor |
| Output II | signal or fault message ; Transistor |
Fault indication output
| Connection | SL1: 6b |
| Output type | open collector transistor (internal fault bus) |
Transfer characteristics
| Switching frequency | ≤ 5 kHz |
Galvanic isolation
| Output/power supply | basic insulation acc. to EN 50178, rated insulation voltage of 50 V AC |
| Output/Output | basic insulation acc. to EN 50178, rated insulation voltage of 50 V AC |
Indicators/settings
| Display elements | LEDs |
| Control elements | DIP switch |
| Factory setting | input close, transistor closed, lead fault detection enabled |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Galvanic isolation | EN 50178:1997 |
| Electromagnetic compatibility | NE 21:2012For further information see system description. |
| Degree of protection | IEC 60529:2001 |
| Protection against electrical shock | IEC 61140 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Relative humidity | ≤ 90 % , non-condensing |
Mechanical specifications
| Degree of protection | IP20 |
| Mass | approx. 90 g |
| Dimensions | 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D) |
| Mounting | on termination board |
| Coding | pin 1 and 2 trimmed For further information see system description. |
Data for application in connection with hazardous areas
| EU-type examination certificate | BVS 09 ATEX E 157 |
| Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IInputEx ia, Ex iaDVoltageUo10.5 VCurrentIo17.1 mAPowerPo45 mW (linear characteristic) | Marking |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Input | Ex ia, Ex iaD |
| Voltage | 10.5 V Uo |
| Current | 17.1 mA Io |
| Power | 45 mW (linear characteristic) Po |
| Supply | |
| Maximum safe voltageUm253 V AC (Attention! Um is no rated voltage.) | Um Maximum safe voltage |
| Maximum safe voltage | 253 V AC (Attention! Um is no rated voltage.) Um |
| Output | |
| Maximum safe voltageUm253 V AC (Attention! The rated voltage can be lower.) | Um Maximum safe voltage |
| Maximum safe voltage | 253 V AC (Attention! The rated voltage can be lower.) Um |
| Galvanic isolation | |
| Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | Input/Output |
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Input/power supply | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000 |
International approvals
| UL approval | E106378 |
| Control drawing116-0331 | Control drawing |
| Control drawing | 116-0331 |
| IECEx approval | |
| IECEx certificateIECEx BVS 09.0060IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I | IECEx certificate |
| IECEx certificate | IECEx BVS 09.0060 |
| IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G