What is the Pepperl Fuchs EXTA4-*1-**-K4* (2024 Generation)?
Degree of protection: IP66
Stainless steel housing
National layout variants available for US, GER and FR
PC-compatible-keyboard with 105 short stroke keys
Designed for use in Zone 1/21 and Zone 2/22 hazardous areas
USB interface with USB cable
UL listed for USA and Canada
Ex i keyboard with touch pad, Degree of protection: IP66, Stainless steel housing, National layout variants available for US, GER and FR, PC-compatible-keyboard with 105 short stroke keys, Designed for use in Zone 1/21 and Zone 2/22 hazardous areas, USB interface with USB cable, UL listed for USA and Canada
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | T221629 |
| Type | Keyboard with touch pad |
| Suitable components | SK-PC-Z1D1-UU1-10-HS and SK-PC-D2-UU1-10-HS |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Supply
| Rated voltage | Ex i, via data line Ur |
Indicators/operating means
| Keyboard | 105 short stroke keys Keyboard layout: US international, German, French |
| Touchpad: Active Principle | Capacitive |
| Touchpad: Resolution | 10 Pts/mm x 10 Pts/mm |
| Touchpad: Dimensions | 66 x 50 |
Interface
| Interface type | USB |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2021 (Ind loc) EN 61000-6-4:2007+A1:2011 EN 55011:2016+A11:2020 (Class B) |
| Explosion protection: Directive 2014/34/EU | EN IEC 60079-0:2018 EN 60079-11:2012 |
| RoHS: Directive 2011/65/EU (RoHS) | EN IEC 63000:2018-12 |
Conformity
| Degree of protection | IP66 (with housing) |
Ambient conditions
| Ambient temperature | -20 ... 50 °C (-4 ... 122 °F) |
| Storage temperature | -20 ... 70 °C (-4 ... 158 °F) |
| Relative humidity | max. 85 % , non-condensing |
Mechanical specifications
| Material | anodized aluminum , stainless steel (F1- Mounting Option), Polyester foil |
| Mass | 1.2 kg (without housing) |
| Dimensions | 502 mm x 222 mm x 66 mm |
| Cut out dimensions | 450 mm x 152 mm |
| Cable length | 5 m / 2 m / 1 m |
Data for application in connection with hazardous areas
| EU-type examination certificate | Zone 1/21 BVS 07 ATEX E 163 X Zone 2/22 BVS 21 ATEX E 009 X |
| Marking | Zone 1/21 II 2G Ex ib IIC T4 Gb [exsign] II 2D Ex ib IIIB T135°C Db Zone 2/22 [exsign] II 3G Ex ic IIC T4 Gc [exsign] II 3D Ex ic IIIB T135°C Dc |
International approvals
| UL approval: Control drawing | 116-0357E |
| UL approval: Approved for | Class I Div 2, Gr A, B, C, D; T5 Class II, Div 2; Gr F, G; T5 Class III Class I, Zone 2; Gr IIC; T5 Class II, Zone 22; Gr IIIB; T85°C Class III, Zone 22; Gr IIIA; T85°C |
| IECEx approval: IECEx certificate | Zone 1/21 IECEx BVS 08.0022X Zone 2/22 IECEx BVS 08.0022X |
| IECEx approval: IECEx marking | Zone 1/21 Ex ib IIC T4 Gb Ex ib IIIB T135°C Db Zone 2/22 Ex ic IIC T4 Gc Ex ic IIIB T135°C Dc |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
- 3-D model (STEP) EXTA4-*1-**-K8* (2024 Generation)
- 3-D model (STEP) EXTA4-*1-**-K8* (2024 Generation)
- 3-D model (STEP) EXTA4-*1-**-K8* (2024 Generation)
- 3-D model (STEP) EXTA4-*1-**-K8* (2024 Generation)
- 3-D model (STEP) EXTA4-*1-**-K8* (2024 Generation)
- 3-D model (STEP) EXTA4-*1-**-K8* (2024 Generation)
EXTA4-*1-**-K4* (2024 Generation): frequently asked questions
When can EXTA4-*1-**-K4* (2024 Generation) be shipped?
EXTA4-*1-**-K4* (2024 Generation) is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up EXTA4-*1-**-K4* (2024 Generation) in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for EXTA4-*1-**-K4* (2024 Generation) and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for EXTA4-*1-**-K4* (2024 Generation), subject to availability and destination.
More Pepperl Fuchs parts