Pepperl Fuchs DP-LBF-I1.36.*
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Surge Protection |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can DP-LBF-I1.36.* be shipped?
DP-LBF-I1.36.* is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up DP-LBF-I1.36.* in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for DP-LBF-I1.36.* and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for DP-LBF-I1.36.*, subject to availability and destination.
Surge Protector. Surge protector, module for control cabinet installation (Ex ia), Modular: protection module easy to replace, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Protection module replaceable, interrupting or non-interrupting, Grounding of shield direct or via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Canada. Design / Mounting: Cabinet installation. Installation in hazardous area: Zone 1 / Div. 1. Rated voltage: 33 V. Rated current: 500 mA. Voltage protection level: . Line/Linemax. 58 V category C1/C28/20 µsecmax. 50 V category C3 1 kV/µsecmax. 51 V category B2 10/700 µsecmax. 55 V category D1 10/350 µsecLine/Earthmax. 1400 V category C1/C28/20 µsecmax. 1100 V category C1/C21 kV/µsecmax. 1000 V category B2 10/700 µsecmax. 1300 V category D1 10/350 µsecScreen/Shield directly groundedmax. 25 V category C1/C28/20 µsecmax. 20 V category D1 10/350 µsecScreen/Shield indirectly grounded (via GDT)max. 700 V category C1/C28/20 µsecmax. 600 V category C3 1 kV/µsecmax. 500 V category B2 10/700 µsecmax. 600 V category D1 10/350 µsec: . Line/Line: max. 58 V category C1/C28/20 µsecmax. 50 V category C3 1 kV/µsecmax. 51 V category B2 10/700 µsecmax. 55 V category D1 10/350 µsec. Line/Earth: max. 1400 V category C1/C28/20 µsecmax. 1100 V category C1/C21 kV/µsecmax. 1000 V category B2 10/700 µsecmax. 1300 V category D1 10/350 µsec. Screen/Shield directly grounded: max. 25 V category C1/C28/20 µsecmax. 20 V category D1 10/350 µsec. Screen/Shield indirectly grounded (via GDT): max. 700 V category C1/C28/20 µsecmax. 600 V category C3 1 kV/µsecmax. 500 V category B2 10/700 µsecmax. 600 V category D1 10/350 µsec. Reaction time: . Line/Linemax. 1 nsLine/Earthmax. 100 nsScreen/Shield-Earthmax. 100 ns: . Line/Line: max. 1 ns. Line/Earth: max. 100 ns. Screen/Shield-Earth: max. 100 ns. Overstressed fault mode: according IEC 61643-21 line inoperable mode 3 lines 1 and 2 at 15,5kA (8/20µsec) lines 3 and 4 at 30kA (8/20µsec). Series resistance in line: 1 Ω +/- 5 %. Impulse durability: . Per line1 kA category D1 10/350 µsec ,5 kA category C1/C28/20 µsecScreen/Shield directly grounded5 kA category D1 10/350 µsecScreen/Shield indirectly grounded (via GDT)4 kA category D1 10/350 µsec ,10 kA category C1/C28/20 µsec: . Per line: 1 kA category D1 10/350 µsec ,5 kA category C1/C28/20 µsec. Screen/Shield directly grounded: 5 kA category D1 10/350 µsec. Screen/Shield indirectly grounded (via GDT): 4 kA category D1 10/350 µsec ,10 kA category C1/C28/20 µsec. Capacitance: . Line/Line800 pFLine/Earth16 pF: . Line/Line: 800 pF. Line/Earth: 16 pF. Degree of protection: IEC 60529. Fieldbus standard: IEC 61158-2. Climatic conditions: IEC 60721. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Surge protection: IEC 61643-21. Ambient temperature: -50 ... 80 °C (-58 ... 176 °F). Storage temperature: -50 ... 85 °C (-58 ... 185 °F). Relative humidity: ≤ 95 % non-condensing. Shock resistance: 15 g 11 ms. Vibration resistance: 1 g , 10 ... 150 Hz. Connection type: screw terminals. Core cross section: flexible wire 2.5 mm2 solid wire max. 4 mm2. Housing material: Polyamide PA 6.6. Degree of protection: IP20. Mass: Protection Module 20 g , base module 40 g. Mounting: DIN rail mounting. EU-type examination certificate: KEMA 09 ATEX 0191 X. Marking II 2(1)G Ex ia [ia Ga] IIC T6...T4 GbVoltageUi30 VCurrentIi500 mAInternal capacitanceCinegligible 0 nFInternal inductanceLi negligible 0 µH: . Marking: II 2(1)G Ex ia [ia Ga] IIC T6...T4 Gb. Voltage: 30 V. Current: 500 mA. Internal capacitance: negligible 0 nF. Internal inductance: negligible 0 µH. Certificate: KEMA 09 ATEX 0190 X. Marking II 3G Ex ic IIC T6...T4 Gc , [exsign] II 3G Ex ec IIC T6...T4 GcVoltageUi33 VCurrentIi500 mAInternal capacitanceCinegligible 0 nF: . Marking: II 3G Ex ic IIC T6...T4 Gc , [exsign] II 3G Ex ec IIC T6...T4 Gc. Voltage: 33 V. Current: 500 mA. Internal capacitance: negligible 0 nF. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+A11:2024 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018+A11:2024 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012. CSA approval: CSA 2437472. Control drawing116-0361Approved forClass I, Zone 1, AEx/Ex ia IIC T4...T6, Class I, Zone 2, AEx nC IIC T4...T6, Class I, Zone 2, Ex nL IIC T4...T6, Class I, Zone 2, AEx/Ex nA IIC T4...T6 Class I Div. 1, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6: . Control drawing: 116-0361. Approved for: Class I, Zone 1, AEx/Ex ia IIC T4...T6, Class I, Zone 2, AEx nC IIC T4...T6, Class I, Zone 2, Ex nL IIC T4...T6, Class I, Zone 2, AEx/Ex nA IIC T4...T6 Class I Div. 1, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6. IECEx approval: IECEx KEM 09.0088X. Approved forEx ia [ia Ga] IIC T6...T4 Gb ,Ex ic IIC T6...T4 Gc , Ex ec IIC T6...T4 Gc: . Approved for: Ex ia [ia Ga] IIC T6...T4 Gb ,Ex ic IIC T6...T4 Gc , Ex ec IIC T6...T4 Gc. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Design / Mounting | Cabinet installation |
| Installation in hazardous area | Zone 1 / Div. 1 |
Electrical specifications
| Rated voltage | 33 V Ur |
| Rated current | 500 mA Ir |
| Voltage protection level | Up |
| Line/Linemax. 58 V category C1/C28/20 µsecmax. 50 V category C3 1 kV/µsecmax. 51 V category B2 10/700 µsecmax. 55 V category D1 10/350 µsecLine/Earthmax. 1400 V category C1/C28/20 µsecmax. 1100 V category C1/C21 kV/µsecmax. 1000 V category B2 10/700 µsecmax. 1300 V category D1 10/350 µsecScreen/Shield directly groundedmax. 25 V category C1/C28/20 µsecmax. 20 V category D1 10/350 µsecScreen/Shield indirectly grounded (via GDT)max. 700 V category C1/C28/20 µsecmax. 600 V category C3 1 kV/µsecmax. 500 V category B2 10/700 µsecmax. 600 V category D1 10/350 µsec | Line/Line |
| Line/Line | max. 58 V category C1/C28/20 µsecmax. 50 V category C3 1 kV/µsecmax. 51 V category B2 10/700 µsecmax. 55 V category D1 10/350 µsec |
| Line/Earth | max. 1400 V category C1/C28/20 µsecmax. 1100 V category C1/C21 kV/µsecmax. 1000 V category B2 10/700 µsecmax. 1300 V category D1 10/350 µsec |
| Screen/Shield directly grounded | max. 25 V category C1/C28/20 µsecmax. 20 V category D1 10/350 µsec |
| Screen/Shield indirectly grounded (via GDT) | max. 700 V category C1/C28/20 µsecmax. 600 V category C3 1 kV/µsecmax. 500 V category B2 10/700 µsecmax. 600 V category D1 10/350 µsec |
| Reaction time | tA |
| Line/Linemax. 1 nsLine/Earthmax. 100 nsScreen/Shield-Earthmax. 100 ns | Line/Line |
| Line/Line | max. 1 ns |
| Line/Earth | max. 100 ns |
| Screen/Shield-Earth | max. 100 ns |
| Overstressed fault mode | according IEC 61643-21 line inoperable mode 3 lines 1 and 2 at 15,5kA (8/20µsec) lines 3 and 4 at 30kA (8/20µsec) |
| Series resistance in line | 1 Ω +/- 5 % |
| Impulse durability | |
| Per line1 kA category D1 10/350 µsec ,5 kA category C1/C28/20 µsecScreen/Shield directly grounded5 kA category D1 10/350 µsecScreen/Shield indirectly grounded (via GDT)4 kA category D1 10/350 µsec ,10 kA category C1/C28/20 µsec | Per line |
| Per line | 1 kA category D1 10/350 µsec ,5 kA category C1/C28/20 µsec |
| Screen/Shield directly grounded | 5 kA category D1 10/350 µsec |
| Screen/Shield indirectly grounded (via GDT) | 4 kA category D1 10/350 µsec ,10 kA category C1/C28/20 µsec |
| Capacitance | |
| Line/Line800 pFLine/Earth16 pF | Line/Line |
| Line/Line | 800 pF |
| Line/Earth | 16 pF |
Standard conformity
| Degree of protection | IEC 60529 |
| Fieldbus standard | IEC 61158-2 |
| Climatic conditions | IEC 60721 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Surge protection | IEC 61643-21 |
Ambient conditions
| Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) |
| Storage temperature | -50 ... 85 °C (-58 ... 185 °F) |
| Relative humidity | ≤ 95 % non-condensing |
| Shock resistance | 15 g 11 ms |
| Vibration resistance | 1 g , 10 ... 150 Hz |
Mechanical specifications
| Connection type | screw terminals |
| Core cross section | flexible wire 2.5 mm2 solid wire max. 4 mm2 |
| Housing material | Polyamide PA 6.6 |
| Degree of protection | IP20 |
| Mass | Protection Module 20 g , base module 40 g |
| Mounting | DIN rail mounting |
Data for application in connection with hazardous areas
| EU-type examination certificate | KEMA 09 ATEX 0191 X |
| Marking II 2(1)G Ex ia [ia Ga] IIC T6...T4 GbVoltageUi30 VCurrentIi500 mAInternal capacitanceCinegligible 0 nFInternal inductanceLi negligible 0 µH | Marking |
| Marking | II 2(1)G Ex ia [ia Ga] IIC T6...T4 Gb |
| Voltage | 30 V Ui |
| Current | 500 mA Ii |
| Internal capacitance | negligible 0 nF Ci |
| Internal inductance | negligible 0 µH Li |
| Certificate | KEMA 09 ATEX 0190 X |
| Marking II 3G Ex ic IIC T6...T4 Gc , [exsign] II 3G Ex ec IIC T6...T4 GcVoltageUi33 VCurrentIi500 mAInternal capacitanceCinegligible 0 nF | Marking |
| Marking | II 3G Ex ic IIC T6...T4 Gc , [exsign] II 3G Ex ec IIC T6...T4 Gc |
| Voltage | 33 V Ui |
| Current | 500 mA Ii |
| Internal capacitance | negligible 0 nF Ci |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+A11:2024 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+A11:2024 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 |
International approvals
| CSA approval | CSA 2437472 |
| Control drawing116-0361Approved forClass I, Zone 1, AEx/Ex ia IIC T4...T6, Class I, Zone 2, AEx nC IIC T4...T6, Class I, Zone 2, Ex nL IIC T4...T6, Class I, Zone 2, AEx/Ex nA IIC T4...T6 Class I Div. 1, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6 | Control drawing |
| Control drawing | 116-0361 |
| Approved for | Class I, Zone 1, AEx/Ex ia IIC T4...T6, Class I, Zone 2, AEx nC IIC T4...T6, Class I, Zone 2, Ex nL IIC T4...T6, Class I, Zone 2, AEx/Ex nA IIC T4...T6 Class I Div. 1, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6, Class I Div. 2, GP A, B, C, D T4...T6 |
| IECEx approval | IECEx KEM 09.0088X |
| Approved forEx ia [ia Ga] IIC T6...T4 Gb ,Ex ic IIC T6...T4 Gc , Ex ec IIC T6...T4 Gc | Approved for |
| Approved for | Ex ia [ia Ga] IIC T6...T4 Gb ,Ex ic IIC T6...T4 Gc , Ex ec IIC T6...T4 Gc |
General information
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G