Quick facts
| Availability | Confirmed on request |
| Category | Mitsubishi MELSERVO servo – Servo amplifiers |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can MR-J5-25KB-LL be shipped?
MR-J5-25KB-LL is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up MR-J5-25KB-LL in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for MR-J5-25KB-LL and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for MR-J5-25KB-LL, subject to availability and destination.
The Mitsubishi Electric MR-J5-25KB-LL is a MELSERVO-J5 series in the MELSERVO servo. SSCNET III/H. Specifications and manuals below are Mitsubishi Electric's own data.
Specifications
Product
| Series | MELSERVO servo |
| Category | MELSERVO-J5 series |
| Type | 200 V AC |
| Outline | SSCNET III/H |
Specifications
| Series | MELSERVO-J5 series |
| Power class | 200 V AC |
| Model name | MR-J5-25KB-LL |
| Capacity [kW] | 25 |
| Command interface | SSCNET III/H |
| Output: Voltage | 3-phase 0 V AC to 240 V AC |
| Output: Rated current [A] | 126.0 |
| Main circuit power supply input: Voltage/frequency *1: AC input | 3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz |
| Main circuit power supply input: Voltage/frequency *1: DC input *8 | 283 V DC to 340 V DC |
| Main circuit power supply input: Rated current [A] *6 | 109.7 |
| Main circuit power supply input: Permissible voltage fluctuation: AC input | 3-phase 170 V AC to 264 V AC |
| Main circuit power supply input: Permissible voltage fluctuation: DC input *8 | 241 V DC to 374 V DC |
| Main circuit power supply input: Permissible frequency fluctuation | ±5 % maximum |
| Control circuit power supply input: Voltage/frequency: AC input | 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz |
| Control circuit power supply input: Voltage/frequency: DC input *8 | 283 V DC to 340 V DC |
| Control circuit power supply input: Rated current [A] | 0.3 |
| Control circuit power supply input: Permissible voltage fluctuation: AC input | 1-phase 170 V AC to 264 V AC |
| Control circuit power supply input: Permissible voltage fluctuation: DC input *8 | 241 V DC to 374 V DC |
| Control circuit power supply input: Permissible frequency fluctuation | ±5 % maximum |
| Control circuit power supply input: Power consumption [W] | 45 |
| Interface power supply | 24 V DC ± 10 % (required current capacity: 0.3 A (including CN8 connector signals)) |
| Control method | Sine-wave PWM control/current control method |
| Permissible regenerative power: External regenerative resistor (standard accessory) [W] *2 *3 *13 *14 | 850 (1300) |
| Dynamic brake *4 | External option *15 *16 |
| Command communication cycle *10 | 0.222 ms, 0.444 ms, 0.888 ms |
| Communication function | USB: Connect a personal computer (MR Configurator2 compatible) |
| A/B/Z-phase pulse output | Not supported |
| Analog monitor | 2 channels |
| Analog input | 3 points *19 |
| Digital I/O | DI 1 points, DO 2 points |
| Fully closed loop control | Not supported |
| Load-side encoder interface | Not supported |
| Pressure control: Pressure feedback voltage | 0 V to 10 V |
| Pressure control: Pressure feedback cycle | One-point mode: 62.5 μs, Three-point mode: 125 μs *19 |
| Pressure control: Pressure control mode | Basic mode, pressure model adaptive mode |
| Servo functions | Advanced vibration suppression control II, adaptive filter II, robust filter, quick tuning, auto tuning, one-touch tuning, tough drive function, drive recorder function, machine diagnosis function (including failure prediction), power monitoring function, lost motion compensation function |
| Protective functions | Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor overheat protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneous power failure protection, overspeed protection, error excessive protection |
| Safety sub-function | Refer to " Safety Sub-Functions " for safety sub-functions. |
| Safety performance: Satisfied standards | EN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN IEC 62061 maximum SIL 3, EN 61800-5-2 |
| Safety performance: Mean time to dangerous failure (MTTFd) | MTTFd ≥ 100 [years] (314a) |
| Safety performance: Diagnostic coverage (DC) | DC = Medium, 97.6 % |
| Safety performance: Probability of dangerous Failure per Hour (PFH) | PFH = 6.4 × 10 -9 [1/h] |
| Safety performance: Mission time (T M ) *12 | T M = 20 [years] |
| Satisfied standards | Refer to " Standards and certifications (by product) Products " for compliance with global standards and regulations. |
| Structure (IP rating) | Force cooling, open (IP20) *17 *18 |
| Close mounting: 3-phase power supply input | Not possible |
| Environment: Ambient temperature: Operation | 0 °C to 60 °C (non-freezing), Class 3K3 (IEC 60721-3-3) |
| Environment: Ambient temperature: Transportation | -25 °C to 70 °C (non-freezing), Class 2K12 (IEC 60721-3-2) |
| Environment: Ambient temperature: Storage | -25 °C to 70 °C (non-freezing), Class 1K4 (IEC 60721-3-1) |
| Environment: Ambient humidity | 5 %RH to 95 %RH (non-condensing) |
| Environment: Ambience | Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust |
| Environment: Altitude/atmospheric pressure: Operation | Altitude: 2000 m or less *11 |
| Environment: Altitude/atmospheric pressure: Transportation | Overland/sea transportation, or transporting on an airplane whose cargo compartment is pressurized at 700 hPa or higher |
| Environment: Altitude/atmospheric pressure: Storage | Atmospheric pressure: 700 hPa to 1060 hPa (Equivalent to altitudes from -400 m to 3000 m) |
| Environment: Vibration resistance: Operation | Under intermittent vibration: 10 Hz to 57 Hz, displacement amplitude 0.075 mm 57 Hz to 150 Hz, acceleration amplitude 9.8 m/s 2 Class 3M1 (IEC 60721-3-3) Under continuous vibration (directions of X, Y, and Z axes): 10 Hz to 55 Hz, acceleration amplitude 5.9 m/s 2 |
| Environment: Vibration resistance: Transportation | 2 Hz to 9 Hz, displacement amplitude (single amplitude) 7.5 mm 9 Hz to 200 Hz, acceleration amplitude 20 m/s 2 Class 2M3 (IEC 60721-3-2) |
| Environment: Vibration resistance: Storage | 2 Hz to 9 Hz, displacement amplitude (single amplitude) 1.5 mm 9 Hz to 200 Hz, acceleration amplitude 5 m/s 2 Class 1M2 (IEC 60721-3-1) |
| Mass [kg] | 18.1 |
Downloads & documentation
Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.
Data sheets & manuals
More Mitsubishi Electric (Factory Automation) parts
Available on requestMR-J5-25KA-RJ Mitsubishi MELSERVO servo MELSERVO-J5 series
Available on requestMR-J5-25KA4 Mitsubishi MELSERVO servo MELSERVO-J5 series
Available on requestMR-J5-25KA4-RJ Mitsubishi MELSERVO servo MELSERVO-J5 series
Available on requestMR-J5-25KB Mitsubishi MELSERVO servo MELSERVO-J5 series
Available on requestMR-J5-25KB-RJ Mitsubishi MELSERVO servo MELSERVO-J5 series
Available on requestMR-J5-25KB4 Mitsubishi MELSERVO servo MELSERVO-J5 series
Available on requestMR-J5-25KB4-LL Mitsubishi MELSERVO servo MELSERVO-J5 series
Available on requestMR-J5-25KB4-RJ Mitsubishi MELSERVO servo MELSERVO-J5 series