Available on request

FX5UJ-24MT/ESS Mitsubishi MELSEC iQ-F Series CPU Module

MPN: FX5UJ-24MT/ESS · Brand: Mitsubishi Electric (Factory Automation)
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryMitsubishi MELSEC iQ-F Series – CPU Module
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FX5UJ-24MT/ESS be shipped?

FX5UJ-24MT/ESS is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FX5UJ-24MT/ESS in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FX5UJ-24MT/ESS and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FX5UJ-24MT/ESS, subject to availability and destination.

The Mitsubishi Electric FX5UJ-24MT/ESS is a CPU Module in the MELSEC iQ-F Series. AC power supply DC input Screw terminal block type Input: 14 points 24 V DC sink/source Output: 10 points Transistor source Built-in high-speed counter: Up to 4 ch 100 kHz + 4 ch 10 kHz Built-in positioning: Up to 200 kHz 3 axis Built-in Ethernet port: 1 ch Built-in USB port: 1 ch. Specifications and manuals below are Mitsubishi Electric's own data.

Specifications

Product

SeriesMELSEC iQ-F Series
CategoryCPU Module
OutlineAC power supply DC input Screw terminal block type Input: 14 points 24 V DC sink/source Output: 10 points Transistor source Built-in high-speed counter: Up to 4 ch 100 kHz + 4 ch 10 kHz Built-in positioning: Up to 200 kHz 3 axis Built-in Ethernet port: 1 ch Built-in USB port: 1 ch

Specifications

Control systemStored-program repetitive operation
Input/output control systemRefresh system (Direct access input/output allowed by specification of direct access input/output [DX, DY])
No. of input/output points: (1) No. of input/output points256 points or less
No. of input/output points: (2) No. of remote I/O points256 points or less
No. of input/output points: Total No. of points of (1) and (2)256 points or less
Programming specifications: Programming languageLadder diagram (LD), structured text (ST), function block diagram/ladder diagram (FBD/LD), sequential function chart (SFC)* *For supported versions, refer to MELSEC iQ-F FX5 User's Manual (Application).
Programming specifications: Programming extension functionFunction block (FB), function (FUN), label programming (local/global)
Programming specifications: Constant scan0.5 to 2000 ms (can be set in 0.1 ms increments)
Programming specifications: Fixed cycle interrupt1 to 60000 ms (can be set in 1 ms increments)
Programming specifications: Timer performance specifications100 ms, 10 ms, 1 ms
Programming specifications: No. of program executions32
Programming specifications: No. of FB files16 (Up to 15 for user)
Operation specifications: Execution typeStandby type, initial execution type, scan execution type, fixed scan execution type, event execution type
Operation specifications: Interrupt typeInternal timer interrupt, input interruption, high-speed comparison match interrupt, interrupt by modules* *Interrupt from the intelligent function module and high-speed pulse input/output module.
Command processing time: LD X034 ns
Command processing time: MOV D0 D134 ns
Memory capacity: Program capacity48 k steps (96 kbytes, flash memory)
Memory capacity: SD memory cardMemory card capacity (SD/SDHC memory card: Max. 16 Gbytes)
Memory capacity: Device/label memory120 kbytes
Memory capacity: Data memory/standard ROM5 Mbytes
Flash memory (Flash ROM) write countMaximum 20000 times
File storage capacity: Device/label memory1
File storage capacity: Data memory: P: No. of program files32
File storage capacity: Data memory: FB: No. of FB files16
File storage capacity: SD memory card: 2 Gbytes511 The number of files stored in the root folder.
File storage capacity: SD memory card: 4 Gbytes, 8 Gbytes, 16 Gbytes65534 The number of files stored in the root folder.
Clock function: Display dataYear, month, day, hour, minute, second, day of week (leap year automatic detection)
Clock function: PrecisionDifferences per month ±45 sec./25℃ (TYP)
Power failure retention (clock data): Retention methodLarge-capacity capacitor Clock data is retained using the power accumulated in a large-capacity capacitor incorporated into the PLC. When voltage of the large capacity capacitor drops, clock data is no longer accurately retained. The retention period of a fully charged capacitor (electricity is conducted across the PLC for at least 30 minutes) is 15 days (ambient temperature: 25℃). How long the ca
Power failure retention (clock data): Retention time15 days (ambient temperature: 25℃)
Power failure retention (device): Power failure retention capacityMax. 12 k words

Number of device points

No. of user device points: Input relay (X): Octal1024 points The total number of X and Y assigned to input/output points is up to 256 points.
No. of user device points: Output relay (Y): Octal1024 points The total number of X and Y assigned to input/output points is up to 256 points.
No. of user device points: Internal relay (M): Decimal7680 points
No. of user device points: Latch relay (L): Decimal7680 points
No. of user device points: Link relay (B): Hexadecimal2048 points
No. of user device points: Annunciator (F): Decimal128 points
No. of user device points: Link special relay (SB): Hexadecimal2048 points
No. of user device points: Step relay (S): Decimal4096 points
No. of user device points: Timer system (Timer (T)): Decimal512 points
No. of user device points: Accumulation timer system (Accumulation timer (ST)): Decimal16 points
No. of user device points: Counter system (Counter (C)): Decimal256 points
No. of user device points: Counter system (Long counter (LC)): Decimal64 points
No. of user device points: Data register (D): Decimal8000 points
No. of user device points: Link register (W): Hexadecimal1024 points
No. of user device points: Link special register (SW): Hexadecimal1024 points
No. of system device points: Special relay (SM): Decimal10000 points
No. of system device points: Special register (SD): Decimal12000 points
Module access device: Intelligent function module device: DecimalDepends on the intelligent function module.
No. of index register points: Index register (Z): Decimal20 points
No. of index register points: Long index register (LZ): Decimal2 points
No. of file register points: File register (R): Decimal32768 points
No. of file register points: Extended file register (ER): Decimal32768 points (are stored in SD memory card)
No. of nesting points: Nesting (N): Decimal15 points
No. of pointer points: Pointer (P): Decimal2048 points
No. of pointer points: Interrupt pointer (I): Decimal178 points
Others: Decimal constant (K): Signed16 bits: -32768 to +32767 32 bits: -2147483648 to +2147483647
Others: Decimal constant (K): Unsigned16 bits: 0 to 65535 32 bits: 0 to 4294967295
Others: Hexadecimal constant (H)16 bits: 0 to FFFF 32 bits: 0 to FFFFFFFF
Others: Real constant (E): Single precisionE-3.40282347+38 to E-1.17549435-38, 0, E1.17549435-38 to E3.40282347+38
Others: Character stringShift-JIS code max. 255 single-byte characters (256 including NULL)

Power supply specifications

Rated voltage100 to 240 V AC
Voltage fluctuation range-15%, +10%
Frequency rating50/60 Hz
Allowable instantaneous power failure timeOperation can be continued upon occurrence of instantaneous power failure for 10 ms or less. When the supply voltage is 200 V AC or higher, the time can be change to 10 to 100 ms by editing the user program.
Power fuse250 V, 3.15 A Time-lag fuse
Rush current25 A max. 5 ms or less/100 V AC 50 A max. 5 ms or less/200 V AC
Power consumption30 W This item shows value when all 24 V DC service power supplies are used in the maximum configuration connectable to the CPU module. (The current of the input circuit is included.)
24 V DC service power supply capacity[When using 24 V DC service power supply for input circuit of CPU module] 400 mA [When using external power supply for input circuit of CPU module] 460 mA When I/O modules are connected, they consume current from the 24 V DC service power supply. For details on the 24 V DC service power supply, refer to MELSEC iQ-F FX5S/FX5UJ/FX5U/FX5UC User's Manual (Hardware).

Input specifications

No. of input points14 points
Input connection typeRemovable terminal block (M3 screws)
Input typeSink/source
Input signal voltage24 V DC +20%, -15%
Input signal current: X0 to X75.3 mA/24 V DC
Input signal current: X10 and subsequent4.0 mA/24 V DC
Input impedance: X0 to X74.3 kΩ
Input impedance: X10 and subsequent5.6 kΩ
ON input sensitivity current: X0 to X73.5 mA or more
ON input sensitivity current: X10 and subsequent3.0 mA or more
OFF input sensitivity current1.5 mA or less
Input response frequency: X0, X1, X3, X4100 kHz When capturing pulses of a response frequency of 50 to 100 kHz, refer to MELSEC iQ-F FX5S/FX5UJ/FX5U/FX5UC User's Manual (Hardware).
Input response frequency: X2, X5, X6, X710 kHz
Pulse waveform: X0, X1, X3, X4T1 (pulse width): 5 μs or more T2 (rise/fall time): 2.5 μs or less
Pulse waveform: X2, X5, X6, X7T1 (pulse width): 50 μs or more T2 (rise/fall time): 25 μs or less
Input response time (H/W filter delay): X0, X1, X3, X4ON: 5 μs or less OFF: 5 μs or less
Input response time (H/W filter delay): X2, X5, X6, X7ON: 30 μs or less OFF: 50 μs or less
Input response time (H/W filter delay): X10 to X15ON: 50 μs or less OFF: 150 μs or less
Input response time (Digital filter setting value)None, 10 μs, 50 μs, 0.1 ms, 0.2 ms, 0.4 ms, 0.6 ms, 1 ms, 5 ms, 10 ms (initial values), 20 ms, 70 ms When using this product in an environment with much noise, set the digital filter.
Input signal format (Input sensor form)No-voltage contact input Sink: NPN open collector transistor Source: PNP open collector transistor
Input circuit insulationPhoto-coupler insulation
Indication of input operationLED is lit when input is on

Output specifications

No. of output points10 points
Output connection typeRemovable terminal block (M3 screws)
Output typeTransistor/source output
External power supply5-30 V DC
Max. load0.5 A/point The total load current per common terminal should be the following value. 3 output points/common terminal: 0.6 A or less 4 output points/common terminal: 0.8 A or less
Open circuit leakage current0.1 mA or less/30 V DC
Voltage drop when ON: Y0 to Y21.0 V or less
Voltage drop when ON: Y3 and subsequent1.5 V or less
Response time: Y0 to Y22.5 μs or less/10 mA or more (5-24 V DC)
Response time: Y3 and subsequent0.2 ms or less/200 mA or more (24 V DC)
Output circuit insulationPhoto-coupler insulation
Indication of output operationLED is lit when output is on

Specifications

Firmware update functionThis function updates the module's firmware using an SD memory card.
Scan monitoring function (Watchdog timer setting)Detects an error in the hardware and program of the CPU module by monitoring the scan time.
Clock functionThis function is used for the time management in the function which the system operates such as the date of the event history function, and data logging function.
Online change: Online ladder block changeWrites the part of a program edited on the ladder editor using the engineering tool to the CPU module in units of ladder blocks. Edited contents spanning multiple portions can be written to the CPU module at once.
Interrupt function: Multiple interrupt functionWhen an interrupt occurs while an interrupt program triggered by another cause is running, stops the program if its priority is lower than that of the new interrupt, and runs the higher-priority program whenever its execution condition is satisfied.
PID control functionPerforms PID control by the PID control instruction.
Constant scanKeeps the scan time constant and executes program repeatedly.
Remote operation: Remote RUN/STOPChanges the CPU module status to the RUN/STOP/PAUSE status externally while the RUN/STOP/RESET switch of the CPU module is in RUN status.
Remote operation: Remote PAUSEChanges the CPU module status to the RUN/STOP/PAUSE status externally while the RUN/STOP/RESET switch of the CPU module is in RUN status.
Remote operation: Remote RESETResets the CPU module externally while the CPU module is in the STOP status.
Internal buffer capacity settingSets the capacity of the area (internal buffer) used by the system to temporarily store the results of data logging and memory dump processing.
Initial device value settingSets the initial values of devices used in the program directly (not via the program) to the devices.
Latch functionHolds the contents of the device and label of the CPU module when the power is turned ON etc.
Memory card function: SD memory card forced stopMakes the SD memory card unavailable without turning OFF the power even when the function accessing the SD memory card is executed.
Memory card function: Boot operationTransfers the file stored in the SD memory card to the transfer destination memory judged automatically by the CPU module when the power is turned ON or is reset.
Device/label access service processing settingSets the number of execution times of the device/label access service processing executed by END processing, with parameter.
Data logging functionCollects data at the specified interval or any desired timing, and stores them as a file on the SD memory card.
Memory dump functionSaves the data in the devices of the CPU module at a desired timing.
Real-time monitor functionMonitors the data in the specified device of the CPU module at a specified interval or at a desired timing in real time.
RAS function: Self-diagnostics functionSelf-diagnoses the CPU module to see whether an error exist or not.
RAS function: Error clearBatch-clears all the continuation errors being detected.
RAS function: Event history functionCollects operations executed and errors detected from the modules, and saves them in the CPU module, expansion board, expansion adapter, and intelligent module. The saved logs can be checked in chronological order.
Data backup/restoration functionBacks up program files, parameter files, and device/label data files in a CPU module to an SD memory card. The backup data can be restored as needed.
Security functionProtects resources stored in PCs and resources in the units in the system of the FX5 from illegal access by a third party such as theft, alteration, accidental operation and unauthorized execution.
IP filter functionIdentifies the IP address of external devices over Ethernet, and blocks access from an invalid IP address.
High-speed input/output function: High-speed counter functionPerforms high-speed counter, pulse width measurement, input interruption, etc. by using the input of the CPU module or high-speed pulse input/output module.
High-speed input/output function: Pulse width measurement functionPerforms high-speed counter, pulse width measurement, input interruption, etc. by using the input of the CPU module or high-speed pulse input/output module.
High-speed input/output function: Input interrupt functionPerforms high-speed counter, pulse width measurement, input interruption, etc. by using the input of the CPU module or high-speed pulse input/output module.
High-speed input/output function: Positioning functionExecutes positioning operation by using the transistor output of the CPU module or high-speed pulse input/output module.
High-speed input/output function: PWM output functionExecutes a PWM output by using the transistor output of the CPU module or high-speed pulse input/output module.
Built-in Ethernet functionAn Ethernet related function such as connection to MELSOFT products and GOTs, socket communication, file transfer using FTP, Web server (HTTP), SNTP client, and simple CPU communication function.
CC-Link IE Field Network Basic functionThis function exchanges data between the manager station and remote station using general-purpose Ethernet.
Serial communication functionA function related to the serial communication such as N:N Network, parallel link, MC protocol, inverter communication function and non-protocol communication.
MODBUS communication functionConnection with the products which support MODBUS RTU/TCP is available. The master and slave functions can be used.

Specifications

Operating ambient temperature0 to 55℃, non-freezing The simultaneous ON ratio of available PLC inputs or outputs changes with respect to the ambient temperature, refer to MELSEC iQ-F FX5S/FX5UJ/FX5U/FX5UC User's Manual (Hardware).
Storage ambient temperature-25 to 75℃, non-freezing
Operating ambient humidity5 to 95%RH, non-condensation When used in a low-temperature environment, use in an environment with no sudden temperature changes. If there are sudden temperature changes because of opening/closing of the control panel or other reasons, condensation may occur, which may cause a fire, fault, or malfunction. Furthermore, use an air conditioner in dehumidifier mode to prevent condensation.
Storage ambient humidity5 to 95%RH, non-condensation
Vibration resistance: Installed on DIN rail: Frequency: 5 to 8.4 HzHalf amplitude: 1.75 mm 10 times each in X, Y, Z directions (80 min in each direction) The criterion is shown in IEC61131-2. When the system has equipment which specification values are lower than above mentioned vibration resistance specification values, the vibration resistance specification of the whole system is corresponding to the lower specification.
Vibration resistance: Installed on DIN rail: Frequency: 8.4 to 150 HzAcceleration: 4.9 m/s 2 10 times each in X, Y, Z directions (80 min in each direction) The criterion is shown in IEC61131-2. When the system has equipment which specification values are lower than above mentioned vibration resistance specification values, the vibration resistance specification of the whole system is corresponding to the lower specification.
Vibration resistance: Direct installing: Frequency: 5 to 8.4 HzHalf amplitude: 3.5 mm 10 times each in X, Y, Z directions (80 min in each direction) The criterion is shown in IEC61131-2. When the system has equipment which specification values are lower than above mentioned vibration resistance specification values, the vibration resistance specification of the whole system is corresponding to the lower specification.
Vibration resistance: Direct installing: Frequency: 8.4 to 150 HzAcceleration: 9.8 m/s 2 10 times each in X, Y, Z directions (80 min in each direction) The criterion is shown in IEC61131-2. When the system has equipment which specification values are lower than above mentioned vibration resistance specification values, the vibration resistance specification of the whole system is corresponding to the lower specification.
Shock resistance147 m/s 2 , Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z The criterion is shown in IEC61131-2.
Noise durabilityBy noise simulator at noise voltage of 1000 Vp-p, noise width of 1 μs and period of 30 to 100 Hz
Dielectric withstand voltage: Between power supply terminal (AC power supply) and ground terminal1.5 kV AC for one minute
Dielectric withstand voltage: Between 24 V DC service power supply connected to input terminal (24 V DC) and ground terminal500 V AC for one minute
Dielectric withstand voltage: Between output terminal (transistor) and ground terminal500 V AC for one minute
Insulation resistance: Between power supply terminal (AC power supply) and ground terminal10 MΩ or higher by 500 V DC insulation resistance tester
Insulation resistance: Between 24 V DC service power supply connected to input terminal (24 V DC) and ground terminal10 MΩ or higher by 500 V DC insulation resistance tester
Insulation resistance: Between output terminal (transistor) and ground terminal10 MΩ or higher by 500 V DC insulation resistance tester
GroundingClass D grounding (grounding resistance: 100 Ω or less) (Common grounding with a heavy electrical system is not allowed) For grounding, refer to MELSEC iQ-F FX5S/FX5UJ/FX5U/FX5UC User's Manual (Hardware).
Working atmosphereFree from corrosive or flammable gas and excessive conductive dust
Operating altitude0 to 2000 m The PLC cannot be used at a pressure higher than the atmospheric pressure to avoid damage.
Installation locationInside a control panel The programmable controller is assumed to be installed in an environment equivalent to indoor.
Overvoltage categoryII or less This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V.
Pollution degree2 or less This index indicates the degree to which conductive material is generated in the environment in which the equipment is used. Pollution level 2 is when only non-conductive pollution occurs. Temporary conductivity caused by condensation must be expected occasionally.

Downloads & documentation

Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.

Data sheets & manuals

MELSEC iQ-F FX5UJ CPU Module Hardware Manual (IB-0800636)PDF · 0.57MB
MELSEC iQ-F FX5 Programming Manual (Program Design) (JY997D55701-M)PDF · 2.22MB
MELSEC iQ-F FX5 Programming Manual (Instructions, Standard Functions/Function Blocks) (JY997D55801-AB)PDF · 12.39MB
MELSEC iQ-F FX5S/FX5UJ/FX5U/FX5UC User's Manual (Hardware) (SH-082452ENG-Q)PDF · 7.58MB
MELSEC iQ-F FX5 CPU Module Function Block Reference (JY997D62701-L)PDF · 1.44MB
MELSEC iQ-F FX5 User's Manual (Communication) (SH-082625ENG-J)PDF · 15.18MB
MELSEC iQ-F FX5 User's Manual (Application) (JY997D55401-AG)PDF · 13.14MB
MELSEC iQ-F FX5 Ethernet, EtherNet/IP, CC-Link IE Function Block Reference (JY997D64901-S)PDF · 3.51MB
MELSEC iQ-F Statistical Analysis Function Block Reference (Basic) (SH-082093ENG-E)PDF · 1.40MB
MELSEC iQ-F Inverter Control for Automated Warehouses Function Block Library Reference (SH-082575ENG-B)PDF · 4.41MB
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Mitsubishi Electric (Factory Automation) parts

FX5UJ-24MR/ES Mitsubishi MELSEC iQ-F Series CPU ModuleAvailable on requestFX5UJ-24MR/ES Mitsubishi MELSEC iQ-F Series CPU Module
MPN: FX5UJ-24MR/ES · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FX5UJ-24MT/DS Mitsubishi MELSEC iQ-F Series CPU ModuleAvailable on requestFX5UJ-24MT/DS Mitsubishi MELSEC iQ-F Series CPU Module
MPN: FX5UJ-24MT/DS · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FX5UJ-24MT/DSS Mitsubishi MELSEC iQ-F Series CPU ModuleAvailable on requestFX5UJ-24MT/DSS Mitsubishi MELSEC iQ-F Series CPU Module
MPN: FX5UJ-24MT/DSS · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FX5UJ-24MT/ES Mitsubishi MELSEC iQ-F Series CPU ModuleAvailable on requestFX5UJ-24MT/ES Mitsubishi MELSEC iQ-F Series CPU Module
MPN: FX5UJ-24MT/ES · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FX5UJ-40MR/DS Mitsubishi MELSEC iQ-F Series CPU ModuleAvailable on requestFX5UJ-40MR/DS Mitsubishi MELSEC iQ-F Series CPU Module
MPN: FX5UJ-40MR/DS · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FX5UJ-40MR/ES Mitsubishi MELSEC iQ-F Series CPU ModuleAvailable on requestFX5UJ-40MR/ES Mitsubishi MELSEC iQ-F Series CPU Module
MPN: FX5UJ-40MR/ES · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FX5UJ-40MT/DS Mitsubishi MELSEC iQ-F Series CPU ModuleAvailable on requestFX5UJ-40MT/DS Mitsubishi MELSEC iQ-F Series CPU Module
MPN: FX5UJ-40MT/DS · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FX5UJ-40MT/DSS Mitsubishi MELSEC iQ-F Series CPU ModuleAvailable on requestFX5UJ-40MT/DSS Mitsubishi MELSEC iQ-F Series CPU Module
MPN: FX5UJ-40MT/DSS · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote