Available on request

FR-F846-03610-E3-60C3 Mitsubishi FREQROL inverter FR-F800

MPN: FR-F846-03610-E3-60C3 · Brand: Mitsubishi Electric (Factory Automation)
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryMitsubishi FREQROL inverter – FREQROL-F800
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FR-F846-03610-E3-60C3 be shipped?

FR-F846-03610-E3-60C3 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FR-F846-03610-E3-60C3 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FR-F846-03610-E3-60C3 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FR-F846-03610-E3-60C3, subject to availability and destination.

The Mitsubishi Electric FR-F846-03610-E3-60C3 is a FR-F800 in the FREQROL inverter. cULus CE(EMC) CE(LVD). Specifications and manuals below are Mitsubishi Electric's own data.

Specifications

Product

SeriesFREQROL inverter
CategoryFR-F800
OutlinecULus CE(EMC) CE(LVD)

Specifications

SeriesFR-F800
TypeThree-phase 400 V class IP55 compatible model Ethernet model
Model nameFR-F846-03610-E3-60C3
Inverter capacity (kW)160.0
Applicable motor capacity (kW) *1160.0
Output: Rated capacity (kVA) *2248.0
Output: Rated current (A)325.0
Output: Overload current rating *3120 % 60 s, 150 % 3 s (inverse-time characteristics) at surrounding air temperature of 40 °C
Output: Voltage *4Three-phase 380 to 500 V
Power supply: Rated input AC voltage and frequencyThree-phase 380 to 500 V, 50/60 Hz *7
Power supply: Permissible AC voltage fluctuation323 to 550 V, 50/60 Hz
Power supply: Permissible frequency fluctuation±5 %
Power supply: Rated input current (A) *5325.0
Power supply: Power supply capacity (kVA) *6248.0
Protective structure: IEC 60529IP55 *9
Protective structure: UL 50UL Type12 *8
Cooling systemForced air + internal fan
DC reactorBuilt-in
Approx. mass (kg)193.0
Control: Control method: CommonSoft-PWM control/High carrier frequency PWM control
Control: Control method: Induction motorSelectable among V/F control, and Advanced magnetic flux vector control
Control: Control method: PM motorPM motor control
Control: Output frequency range: Induction motor0.2 to 590 Hz (The upper-limit frequency is 400 Hz under Advanced magnetic flux vector control.)
Control: Output frequency range: PM motor0.2 to 400 Hz (not operable at a frequency higher than the maximum motor frequency)
Control: Frequency setting and resolution: Analog input0.015 Hz/60 Hz at 0 to 10 V/12 bits (terminals 2 and 4) 0.03 Hz/60 Hz at 0 to 5 V/11 bits or 0 to 20 mA/11 bits (terminals 2 and 4), at 0 to ±10 V/12 bits (terminal 1) 0.06 Hz/60 Hz at 0 to ±5 V/11 bits (terminal 1)
Control: Frequency setting and resolution: Digital input0.01 Hz
Control: Frequency accuracy: Analog inputWithin ±0.2 % of the maximum output frequency (25 °C ±10 °C)
Control: Frequency accuracy: Digital input0.01 % or less of the set output frequency
Control: Voltage/frequency characteristicsBase frequency can be set from 0 to 590 Hz. Constant-torque/variable-torque pattern or adjustable 5 points V/F can be selected.
Control: Starting torque: Induction motorThe following is the specifications for the LD rating. 30 % or less at 1 Hz, 30 % at 3 Hz, 80 % at 6 Hz (V/F control) 120 % at 0.5 Hz (Advanced magnetic flux vector control)
Control: Starting torque: PM motorThe following is the specifications for the LD rating. 50 %
Control: Torque boostManual torque boost (induction motor only)
Control: Acceleration/deceleration time setting0 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode, backlash countermeasures acceleration/deceleration modes are available.
Control: DC injection brake: Induction motorOperation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) variable
Control: DC injection brake: PM motorOperation time (0 to 10 s) variable. Operating voltage (operating current) fixed.
Control: Stall prevention operation levelActivation range of stall prevention operation (0 to 150 %). Whether to use the stall prevention or not can be selected. (V/F control, Advanced magnetic flux vector control)
Operation: Frequency setting signal: Number of analog input3
Operation: Frequency setting signal: Specification of analog inputTerminals 2 and 4 : 0 to 10 V/0 to 5 V/4 to 20 mA (0 to 20 mA) Terminal 1 : -10 to +10 V/-5 to +5 V
Operation: Frequency setting signal: Digital inputInput using the setting dial of the operation panel or parameter unit. Input of four-digit BCD (Binary-coded decimal) or 16-bit binary (when the option FR-A8AX is installed).
Operation: Start signalForward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Operation: Input signal: Number of input signal (Contact input)12
Operation: Input signal: Pulse train input100 k pulses/s
Operation: Input signal: Input terminal function selectable signalLow-speed operation command, Middle-speed operation command, High-speed operation command, Second function selection, Terminal 4 input selection, Jog operation selection, Output stop, Start self-holding selection, Forward rotation command, Reverse rotation command, Inverter reset The signal to be input can be changed using Pr.178 to Pr.189 (Input terminal function selection).
Operation: Operational functionMaximum and minimum frequency settings, Multi-speed operation, Acceleration/deceleration pattern, Thermal protection, DC injection brake, Starting frequency, JOG operation, Output stop (MRS), Stall prevention, Regeneration avoidance, Increased magnetic excitation deceleration, DC feeding, Frequency jump, Rotation display, Automatic restart after instantaneous power failure, Electronic bypass seque
Operation: Output signal: Number of output signal (Open collector output)5
Operation: Output signal: Number of output signal (Relay output)2
Operation: Output signal: Output terminal function selectable signalInverter running, Up to frequency, Instantaneous power failure/undervoltage, Overload warning, Output frequency detection, Fault The signal to be output can be changed using Pr.190 to Pr.196 (Output terminal function selection). Fault codes (4 bits) of the inverter can be output from the open collector.
Operation: Output signal: Pulse train output (FM type inverter)50 k pulses/s
Indication: For indication on external meters: Number of output signal for indication on external meters2
Indication: For indication on external meters: Pulse train output (FM type inverter)Max. 2.4 kHz via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM/CA terminal function selection.
Indication: For indication on external meters: Current output (CA type inverter)Max. 20 mA DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM/CA terminal function selection.
Indication: For indication on external meters: Voltage outputMax. 10 V DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.158 AM terminal function selection.
Indication: Operation panel: Status monitoringOutput frequency, output current, output voltage, and frequency setting value are monitored. The item for monitoring can be changed using Pr.52 Operation panel main monitor selection.
Indication: Operation panel: Fault monitoringWhen a protective function is activated, a fault indication is displayed and the output voltage, output current, output frequency, cumulative energization time, date (year, month, day) and time at the occurrence of the fault are stored. Each fault is recorded and the last 8 records can be displayed.
Protective/warning function: Protective functionOvercurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay functio
Protective/warning function: Warning functionOperation panel lock *10 , Password locked *10 , Parameter write error, Copy operation error, Stall prevention (overcurrent), Stall prevention (overvoltage), Electronic thermal relay function pre-alarm, PU stop, Continuous operation during communication fault *10 , Parameter copy, Safety stop, Maintenance timer *10 , USB host error, Load fault warning, Emergency drive in operation, Fan alarm, Inte
Environment: Surrounding air temperature-10 °C to +50 °C (non-freezing) (LD rating) -10 °C to +40 °C (non-freezing) (SLD rating)
Environment: Surrounding air humidity95 % RH or less (non-condensing)
Environment: Storage temperature *11-20 °C to +65 °C
Environment: AmbienceIndoors (free from corrosive gas, flammable gas, oil mist, dust and dirt)
Environment: Altitude/vibrationMaximum 2500 m *13 , 5.9 m/s 2 or less *12 at 10 to 55 Hz in X, Y, and Z directions
NetworkRS-485 : Mitsubishi inverter protocol Ethernet : CC-Link IE Field Network Basic, MODBUS/TCP, BACnet/IP Option unit : CC-Link IE TSN, CC-Link IE Field Network, CC-Link, DeviceNet, PROFIBUS-DPV0, LONWORKS, FL remote, EtherCAT, EtherNet/IP, PROFINET, PROFIBUS-DPV1

Downloads & documentation

Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.

Data sheets & manuals

FR-F806-E (IP55/UL Type 12 SPECIFICATIONS) INSTRUCTION MANUAL(HARDWARE) (IB-0600765ENG-D)PDF · 6.77MB
FR-F806-E(IP55/UL Type 12 SPECIFICATIONS) INSTRUCTION MANUAL(HARDWARE) (IB-0600766CHN-D)PDF · 7.03MB
FR-F800 INSTRUCTION MANUAL (DETAILED) (IB-0600547ENG-G)PDF · 16.22MB
FR-A800-E/F800-E ETHERNET FUNCTION MANUAL (IB-0600628ENG-D)PDF · 1.72MB
FR-A800-E/F800-E ETHERNET FUNCTION MANUAL (IB-0600629CHN-D)PDF · 1.38MB
FR-A800/F800 Safety Stop Function Instruction Manual (BCN-A23228-001E-K)PDF · 0.88MB
FR-A8AX INSTRUCTION MANUAL (IB-0600495ENG-C)PDF · 0.57MB
FR-A8AY INSTRUCTION MANUAL (IB-0600497ENG-C)PDF · 0.59MB
FR-A8AR INSTRUCTION MANUAL (IB-0600499ENG-D)PDF · 0.51MB
FR-A8AP INSTRUCTION MANUAL (IB-0600505ENG-D)PDF · 0.69MB
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Mitsubishi Electric (Factory Automation) parts

FR-F846-03610-2-60L2 Mitsubishi FREQROL inverter FR-F800Available on requestFR-F846-03610-2-60L2 Mitsubishi FREQROL inverter FR-F800
MPN: FR-F846-03610-2-60L2 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-F846-03610-3-60C3 Mitsubishi FREQROL inverter FR-F800Available on requestFR-F846-03610-3-60C3 Mitsubishi FREQROL inverter FR-F800
MPN: FR-F846-03610-3-60C3 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-F846-03610-E2-60C2 Mitsubishi FREQROL inverter FR-F800Available on requestFR-F846-03610-E2-60C2 Mitsubishi FREQROL inverter FR-F800
MPN: FR-F846-03610-E2-60C2 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-F846-03610-E2-60L2 Mitsubishi FREQROL inverter FR-F800Available on requestFR-F846-03610-E2-60L2 Mitsubishi FREQROL inverter FR-F800
MPN: FR-F846-03610-E2-60L2 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-F8AT01 Mitsubishi FREQROL inverter Structure optionAvailable on requestFR-F8AT01 Mitsubishi FREQROL inverter Structure option
MPN: FR-F8AT01 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-HAL-0.4K Mitsubishi FREQROL inverter ReactorAvailable on requestFR-HAL-0.4K Mitsubishi FREQROL inverter Reactor
MPN: FR-HAL-0.4K · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-HAL-0.75K Mitsubishi FREQROL inverter ReactorAvailable on requestFR-HAL-0.75K Mitsubishi FREQROL inverter Reactor
MPN: FR-HAL-0.75K · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-HAL-1.5K Mitsubishi FREQROL inverter ReactorAvailable on requestFR-HAL-1.5K Mitsubishi FREQROL inverter Reactor
MPN: FR-HAL-1.5K · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote